If using other screws, switch may be damaged. (3) Load current range and Maximum load current 5 to 20 mA 5 to 40 mA 20 mA Contact protection circuit None D-A93 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) D-A93V 2.7 V or less Internal voltage drop 0.8 V or less Auto Switch Internal Circuit Colors of lead wire inside ( ) are the ones before conformed to IEC standard.
If using other screws, switch may be damaged. (3) Load current range and Maximum load current 5 to 20 mA 5 to 40 mA 20 mA Contact protection circuit None D-A93 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) D-A93V 2.7 V or less Internal voltage drop 0.8 V or less Auto Switch Internal Circuit Colors of lead wire inside ( ) are the ones before conformed to IEC standard.
A port 1/8 SS3YJ7-20 -05 -A port 1/8 P, R port thread type Manifold type Stations Nil Rc G NPT NPTF -+ -+ -+ -+ 20 21 Type 20 Type 21 2 stations : 20 stations 02 : 20 00F 00N 00T -+ -+ -+ -+ R P R P P port 1/4 R port 1/4 P port 1/8 R port 1/8 Note) If there are more than 6 stations for type 20, or more than 9 stations for 21 type, supply air to both sides of P port and exhaust air from both
) CCW : CW : . 1) (2mm/) 2 1 CCW CW 2 3 OFF(ON) -28- (=) P.25 =02mm) =0 a) CCW 50mm =0() =10 50mm CCW CW 0 10 20 30 40 50 [mm] 50mm CCW CW 10 20 30 40 50 60 [mm] b) CW )50mm =0() =10 =-10 50mm CCW CW -50 -40 -30 -20 -10 0 [mm] 50mm CCW CW -40 -30 -20 -10 0 10 [mm] 50mm CCW CW -60 -50 -40 -30 -20 -10 [mm] -29- 4/ A 50mm () 5m 5m 10% 15m 20% -30- 5./ 5.1 (LEC ) ,,
24.5 55 175 20 8 Front flange type: MQMLF 6 20 2.3 33 42 27.5 2-5.5 66 + Stroke 93.5 + Stroke 10, 16, 20, 25 FY FT FX FZ H 2-FC S + Stroke ZZ + Stroke (mm) Bore size (mm) FC FT FX FY FZ H S ZZ 10 5.5 2.3 33 20 42 28 65 101 16 5.5 2.3 42 24 54 30 74 114 20 7 4 60 34 75 40.5 97.5 151 25 7 4 60 40 75 44.5 102.5 160 14 Series MQM Refer to the basic type on page 13 for other dimensions.
valves, gasket, and optional parts. 8 Series SYJ300 Manifold for Internal Pilot Type Type 20 Applicable solenoid valve SYJ312--M3 SYJ312M--M3 SYJ322--M3 SYJ322M--M3 How to Order A port M3 x 0.5 SS3YJ3--20-05 -Stations Bracket Applicable blanking plate assembly SYJ300-10-1A 02 2 stations Nil Without bracket P R R port : : F With bracket M5 x 0.8 20 20 stations P port Note) For more than
19 20 19 20 19 20 19 20 19 20 19 20 19 20 1 2 3 4 5 6 7 8 9 10 1 2 3 4 NEW CONCEPT N.C. valve N.C. valve N.C. valve N.O. valve N.O. valve N.O. valve 5 6 7 8 9 10 1 2 3 4 R2 B R1 A P IP65 enclosure compliant kit (Lead wire) M 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 5 (R1) 3 (R2) 5 (R1) 3 (R2) 5 (R1) 3 (R2) 1 2 3 4 4 (A) 2 (B) 4 (A) 2 (B) 4 (A) 2 (B) IP65 enclosure compliant
Since this will make it impossible to satisfy the specifications, operate with adjustment within the range of maximum values. 11-5-20 20 Rotary Table: Basic Type Vane Style Series MSUB These drawings indicate the condition when the B port is pressurized.
If using other screws, switch may be damaged. (3) Load current range and Maximum load current 5 to 20 mA 5 to 40 mA 20 mA MU Contact protection circuit None DD-A93 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) D-A93V 2.7 V or less Internal voltage drop 0.8 V or less Auto Switch Internal Circuit Colors of lead wire inside ( ) are the ones before conformed to IEC standard.
N 02 B 2 Z X480 With External Epoxy Coating, Stainless Fasteners Lubricator Body Size Symbol 20 30 40 Name Plate, Caution Plate On Bowl in psi, F Size 1/8 3/8 1/2 Bowl Symbol 2 8 Applicable Body Size 20 30, 40 Description Metal Bowl Metal Bowl With Sight Glass NPT Threads Port Size Symbol 02 03 04 Accessories Symbol Nil B* Applicable Body Size 20 30 40 Port Size 1/4 3/8 1/2 Applicable
Applicable bore size d H B C D E1 C H NX B A L1 A1 U1 I-04A 40 69 22 24 55 M14 x 1.5 15.5 20 12+0.070 0 16 0.1 0.3 I-05A 50, 63 74 27 28 60 M18 x 1.5 15.5 20 12+0.070 0 16 0.1 0.3 I-08A 80 91 37 36 71 M22 x 1.5 22.5 26 18+0.070 0 28 0.1 0.3 I-10A 100 105 37 40 83 M26 x 1.5 24.5 28 20+0.084 0 30 0.1 0.3 NT-04 40 M14 x 1.5 8 22 25.4 21 NT-05 50, 63 M18 x 1.5 11 27 31.2 26 NT-08 80 M22 x 1.5
20 15 15 10 10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40
20 -20 10 0 0 0 0 5 10 15 20 25 0.2 0.3 0.4 0.5 [MPa] [L/min (AMR) ] Pmax Qmax 10 Pmax 2 (P1 Q1 ) 3 Qmax 0 37 - No.ZQ-OM01401-B 11.2 () ZQ000A 11.3 -100 -80 [kPa] -60 -40 -20 0 (V 6 ) 0 5 10 15 20 [L/min (AMR) ] ZQA (PD)() ZQ000A (PD) 100 80 [L/min(ANR)] 70 [L/min(ANR)] 0.5MPa 0.5MPa 80 60 0.4MPa 50 0.35MPa 0.3MPa 60 0.3MPa 40 40 30 20 20 10 0 0 0 1 2 3 4 5 0 1 2 3 4 5 [] [
Item Setting value, setting Default AXIS AXIS AXIS AXIS range value 1 2 3 4 0:mm 3 0 150 300 450 1:inch 2:degree 3:PLS Pr.1 Unit setting Movement Pr.2 Pulse number amount per 1 to 20 (Note 1) 20 2 3 152 153 302 303 452 453 pulse per rotation(AP) (Unit: PLS) Pr.3 Moving amount The setting value range differs according to the "Pr.1 Unit setting". 20 4 5 154 155 304 305 454 455 per rotation
Black White @4 5 or less Insulation resistance, M/km, 20C White None @5 Note) The minimum inside bending radius for each cable is 20 mm.
2110 20 21Direct Operated Precision Regulator (For Special Applications) Direct Operated Precision Regulator with Backflow Function (For Special Applications) Series ARP20K to ARP40K 10 20 2110 20 21-ARP20/ARP20K 10 20 21 -ARP30/ARP30K 10 20 21 -ARP40/ARP40K 10 20 21 Description Symbol Body size 20 30 40 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting
Model VEX55 04 06 10 Description VEX5710 12 VEX5914 20 Bracket (With bolt and washer) G46-10-01 VEX7-32A VEX5-32A VEX9-32A Pressure gauge 5.1-27 How to Order How to Order Pilot valve 1 06 2 E Z 5 1 B VEX5 SF4 20 B Bracket Option Electrical entry Economy valve Coil rated voltage G Pressure gauge (Ex.)
bracket Port size Model C B A Drain piping F G H J K L B' D E 6 6 1/4 female thread M3 x 0.5 1 4 2.3 15 12 20 50 73 AMC220 40 56 88 100 22 Depth 8 Body size A B C M3 x 0.5 71 88 101 101 121 55 63 83 96 96 116 1 4 3 8 , 56 75 102 118 135 153 AMC320 75 120.5 140.5 2.3 15 20 30 50 123.5 24 55 2 3 5 6 8 9 Depth 8 M4 x 0.7 1 2 3 4 AMC520 102 173.5 193.5 3.2 Depth 8 20 20 30 70 176.5 , 40 70
25 30 4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated steam holding heat (kcal/kg).