200 150 100 0 50 Supply pressure (kPa) Supply pressure (kPa) 870 Air Catch Sensor Series ISA2 Response Time (Typical example) Response time changes with detection distance and piping length.
Impact acceleration [m/s2] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration 8-18-2 in vacuum environments (1.3 x 104 Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.
100 150 200 50 100 150 200 Arm length [mm] Arm length [mm] The maximum clamping force when the arm length is 100 mm and the operating pressure is 44 psi [0.3 MPa]: With an arm length of 100 mm and an operating pressure of 44 psi [0.3 MPa], according to the graph, the maximum clamping force is 45 lbf [200 N].
] L2 = 50 [mm] D-X L2 L1 20Data Item Load factor n Note 1.
One-touch fitting for 1/4" N7 SX5000 One-touch fitting for 5/16" N9 One-touch fitting for 5/16" N9 SX7000 One-touch fitting for 3/8" N11 The LN or MN option includes 2 sockets for single solenoid valves and 3 sockets for double solenoid valves. 1-6-12 Body Ported Series SX3000/5000/7000 Specifications SX3000 SX5000 SX7000 Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 Max. 50 Series Fluid 2 position
If the driving direction is unclear, operate the actuator slowly with a small move distance while checking the driving direction. -50- 5.7 Positioning (Point Table) Operation using the Setup Software This feature is only available in positioning (point table) mode.
Impact acceleration [m/s] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration Features 1 in vacuum environments (1.3 x 10-Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.
Performance Performance data given in this chapter is based on an electrified plate (dimensions: 150 x 150 mm, electrostatic capacity: 20 pF) defined by ANSI standard (ANSI/ESD STM3.1-2006).
Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.
Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
Air cylinder 40, 50, 63 10-/1121-/22Series CA2 How to Order Clean series 10 11 Relief type Vacuum suction type Mounting style Basic style Axial foot style Rod side flange style Head side flange style B L F G Bore size (mm) Port thread type Rc NPT G Nil TN TF 10 C D A 2 B 40 150 Y59B 21 C D A 2 B 40 150 Y59B Nil Built-in magnet Number of auto switches No 2 pcs. 1 pc. "n" pcs.
(N) Backlash Manual release 12 16 20 40 Head end only 8 5, 10, 15, 20, 25, 30 125 211 53 82 329 29 12, 16 25, 50, 75, 100 1 mm Non-lock type only 25, 50, 75, 100, 125, 150, 175, 200 20, 25, 32, 40 Strokes other than the above are produced upon receipt of order. Theoretical Output (N) Stud Bolt Part No.
Symbol Nil 10 mm AM Coating color White 1 Weight lbs (kg) 40 (18) 55 (25) 57 (26) 64 (29) 73 (33) 110 (50) AMD Compliant standards UL, CSA Note 1) ANR is under the conditions of 68F (20C) at atmospheric pressure and relative humidity of 65%. Note 2) Air flow capacity for each outlet air pressure dew point is indicated.
Withstand voltage 500 VAC for 1 min. between FE and all accessible terminals to IEC 61131-2 Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) Atmospheric pressure Operation: 80 kPa to 108 kPa (under 2000 m) Storage: 66 kPa to 108 kPa (under 3500 m) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration
Table 4-1 EX245 24 V DC +20% -15% 1ms IP65 () (IEC60529) 10M -FE 500VAC IEC61131-2 500VAC1 -FE IEC61131-2 -10 to 50 -20 to 60 35%85% RH 80 kPa 108 kPa ( 2000 m ) 66 kPa 108 kPa ( 3500 m ) 10 Hz to 57 Hz 0.75 mm 57 Hz to 150 Hz 49 m/s 2 XYZ 2 XYZ 3 EN 60068-2-27/29 EMC , 2014/30/EU, IEC61326-3-1 , 2006/42/EC, EN 62061, EN ISO 13849 TUV , EN 61508, EN 62061, EN ISO 13849
s o.50 o.8e4 o93 0.75 0.18 %-18 0.50 0.95 2.94 106 (1 0.312 %-24 0.50 o.624 0.25 1.12 o.12 0.88 0.88 0.24 %-8 0.62 1.17 3.25 0.la7 Wzo 0.75 0.7i19 o 1.t2 0.25 1.06 'L06 o.25 %-16 ora 1.62 400 150 t1%l o.87 1h-20 o_75 o.749 0.38 1.56 0.25 1.25 1.25 o.25 3l-16 0.88 '1.50 3.69 Double End : NC.
40 13 13 16 16 19 19 22 22 32 100 63 113 76 119 76 145 90 151 90 166 106 173 106 200 122 253 160 8 12 6 40 66 84 28 5 2.0 27 37 1/4,3/8 172 AMH250 178 1/2 8 12 6 40 66 84 28 5 2.0 27 37 3/8, 1/2 204 AMH350 3/4 210 8 14 7 50 80 100 34 5 2.3 32 37 8 14 7 50 80 100 34 5 2.3 32 37 10 14 9 55 88 110 50 9 3.2 37 37 10 14 9 55 88 110 50 9 3.2 37 37 10 16 9 65 102 130 60 10 4.5 39 37 15 20 11 85
/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Note 1) Value at manifold base mounted, single operating Note 2) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.
125 14-150 18-150 1 Series JS Construction 10, 16 20 to 63 Parts list Parts list No.
(mm) Nominal ID (mm) Bend Radius (mm) 3:1 Burst Pressure (psi)* Tube O.D. 2.5 4 6 8 9 4 6 8 10 12 0.75 1 1 1 1.5 180 150 150 125 100 540 450 450 375 300 25.4 31.8 38 51 63.5 Inch Sizes Shore A 98A, Shore D 55D -50~ +140F (-45~ 60C) 07 11 13 15 1/4 3/8 1/2 5/8 Black Blue Green Natural Red Yellow Color B BU G N R Y Applicable SMC Fitting Series: KQ2, KQG2, KQB2, KG, KB, KS, KX, DMK, KDM Note