HUMIDITY SENSOR. CONDENSATION CHECKER. 158.80000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 142.00000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 167.50000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 168.50000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 168.50000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 168.50000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 153.60000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 154.60000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 167.50000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 143.00000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 128.50000 lb. Q62.
Ported SYA5220-01 2 position double SYA5220(-F2) C4, N3 C6, N7 C8, N9 1/8 (A, B port) M5 x 0.8 (Pilot port) 2 x 3.2 (For manifold mounting) One-touch fitting (A, B port) Applicable tubing O.D.: 4, 5/32" 6, 1/4" 8, 5/16" Manual override (Non-locking) 1/8 (P , EA, EB port) 1.8 (Ventilation hole) 2 x 2.2 die-cast hole (For manifold gasket positioning) SYA5 20-01 3 4 5 3 position closed center
5 Port Air Operated Valve SYA3000/5000/7000 Series How to Order A, B port size Thread type Thread piping One-touch fitting (Inch size) Nil Rc Symbol Port size Applicable series M5 01 02 Symbol Port size Applicable series N3 N7 N3 N7 N9 N9 N11 G F 5 32" SYA3000 SYA5000 SYA7000 One-touch fitting for M5 x 0.8 N NPT SYA3000 1 4" 1 8 1 4 Except for M5 One-touch fitting for NPTF T 5 32" One-touch
Lead wire length symbols: 0.5 mNil (Example) 93A 3 m L (Example) 93AL 5 m Z (Example) 93AZ Since there are other applicable auto switches than listed, refer to page 6-2-9 for details. 6-2-7 2 Pin Cylinder Double Acting, Single Rod Series CJP 6, 10, 15 Specifications Action Double acting, Single rod 10.7 MPa Max. operating pressure 0.7 MPa 6 0.12 MPa Min. operating pressure 10, 15 0.06 MPa
Note 1) 2 1/8, 1/4 3 3/8 4 1/2 Type Metric size Inch size 2 Elbow 3 Universal Tubing O.D. 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Tubing O.D. 23 3.2 Note 2) 04 4 06 6 08 8 10 10 12 12 16 16 Control type 0 Meter-out 1 Meter-in * Meter-out and meter-in types can be visually identified by color of the knob.
Note) When "JUMP instruction" is set for the control system, the "Da.9 Dwell time" and "Da.10 M code" setting details will differ. In cases when you selected "LOOP" as the control system, the "Da.10 M code" should be set differently from other cases. If "degree" is set for Pr.1 Unit setting", circular interpolation control cannot be carried out.
Locking type manual release While pushing the M/O knob turn it 90 counter clockwise. The lock is released (and remains in a released state) by aligning the mark on the cap with the OFF mark on the M/O knob. To operate the lock, turn the M/O knob 90 clockwise while pushing it all the way down, and align the mark on the cap with the ON mark on the M/O knob.
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8
-A14 20 22 12.5 15.5 36 48.5 1 15 ZPT25F10-01-A14 50 25 28 ZPT32F10-01-A14 32 35 13 16 36.5 49 1 15.5 Additional Dimensions by Stroke (mm) H I J Stroke 20 +10 +5.5 0 30 +20 +15.5 50 +40 +60.5 +25 715 ZPT Series 10 13 16 40 50 J K J K ZPT F 10-0-A10 (With buffer/One-touch fitting) ZPT F 10-01-A14 (With buffer/Female thread) Applicable tubing O.D.