SMC Corporation of America
Elite Part Number Search
Search Results "MS-5HLH-6"

Applicable bore size (mm) Flat type +0.048 0 +0.048 0 CJ-T010SUS 10 3.3 A D L MM N R W 4.5 29 18 3.1 2 9 40 22 32 12 Round type CJ-T016SUS 16 5 5.5 35 20 6.4 2.5 14 48 28 38 16 CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 CJ-CF016 CJ-CR016 16 10 12 15 M5 x 0.8 7 12 10 6

Mount the manifold using the 6 base mounting positions with screws. Required screws are as follows: 2 x M5 (End plate: torque = 1.5 Nm) 2 x M5 (SI unit: torque = 1.5 Nm) 4 x M(Valve manifold: refer to valve manifold catalogue) OFF US1 is not present or is below the dropout level (< approx. 17 VDC).

IS ZSM PF2 Pressure Sensor Controller IF Series PSE300 18 9.6 Data Response Time ms 20.8 Set Pressure Resolution Can be mounted in close proximity with each other either horizontally or vertically.

15 AMR 6 37.5 52.7 67.8 75.3 77.8 100 AWM AWD ITV Replacement parts VBA Part No.

800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VP4 VZ1120--M5 (Piping: 6 x 1 m) VZS VFS VS4 AS2001F-06/AN120-M5 AS2301F-M5-06/AN120-M5 Speed controller/Silencer It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.

6 TUZ0805 8 TUZ1065 10 TUZ1208 Tubing O.D.

/O.D. mm 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 167

Note 5) Self-holding type maintains vacuum by instantaneous energization (20 ms or more). Stopping the vacuum turns on the release valve. (signal to stop vacuum not needed) Note 6) When the digital pressure switch for vacuum with energy saving function is selected, select K for t Pressure Sensor/Digital Pressure Switch for Vacuum Specifications.

Polyurethane Coil Tubing Series TCU For flexible tubing Compact piping possible Specifications Model TCU 0425B-1 TCU 0425B-2 2 TCU 0805B-1 1 4 6 8 2.5 4 5 TCU 0425B-3 3 TCU 0604B-1 1 TCU 0604B-2 2 TCU 0604B-3 3 1 Max. operating pressure (2) Fluid Tube I.D. (mm) Tube O.D.

How to Order VS31 3 02 1 5 Thread type Caution Nil Rc N NPT Standard 3 Body size For Safety Instructions and Solenoid Valve Precautions, refer to pages 4-18-2 to 4-18-6.

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN, VALVE

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

Model Model name IC AMR3000 AMR4000 AMR5000 AMR6000 Bracket 13576 13556 13587 13568 VBA G36-10-01 G46-10-02 Pressure gauge 1.0 MPa (5)(6) Accessory (Option)/Part No.

Switch response 5 to 640 ms AMR Power indication: 3 1/2-digit LED indicator (red) Display Output power supply voltage and current signal indication: 1-digit LED indicator (red) ITV LED lights for RUN, CH, SW (red and green) Note 1) Display accuracy 0.5%F .S. 1dig (at 25C) IC Display sampling rate Approx. 4 times/s Temperature characteristics 0.12%F.S.

Note 3) Refer to p.2.10-6 for power consumption of AC type. Note 4) When specifying more than one option, indicate them alphabetically. Note) Standard lead wire length: 300mm With light and surge voltage suppressor.

(mm) 4 4 6 6 8 10 12 16 3.18 4.76 6.35 9.53 12.7 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 T0425 T0604 Tubing I.D.