Broken wire o r coming off 60 sec. 60 sec. AL19 Communication error is generated.
Refer to 4.3.2 Setting and checking,5.3.2 Setting and checking. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
Refer to 4.3.2 Setting and checking,5.3.2 Setting and checking. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
Refer to 4.3.2 Setting and checking,5.3.2 Setting and checking. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
VX2 24 VDC GDM2A-G-S5 100 VAC VXK 110 VAC 200 VAC VXD None 220 VAC GDM2A-R 230 VAC VXZ 240 VAC 24 VAC VXS VXS 48 VAC 24 VDC GDM2A-G-Z5 100 VAC GDM2A-R-L1 110 VAC GDM2A-R-L1 200 VAC GDM2A-R-L2 220 VAC GDM2A-R-L2 230 VAC GDM2A-R-L2 240 VAC GDM2A-R-L2 24 VAC GDM2A-R-L5 48 VAC GDM2A-R-L5 VXB VXE With light VXP VXR VXH VXF Gasket Part No. for DIN Connector VCW20-1-29-1-F VX3 VXA Bracket Assembly
Command Status Check sum code Reset input Command Block # 0 0 R S [CR] Unit No. Command Check sum code Response Block # 0 0 R S [CR] Unit No. Command Status Check sum code HOLD output release Command Block # 0 0 H R [CR] Unit No. Command Check sum code Response Block # 0 0 H R [CR] Unit No. Command Status Check sum code Test transmission Command Block # 0 0 T S [CR] Unit No.
Label (Display item), Set value (Threshold value) Sub screen Set value (Threshold value) Hysteresis value Visualization of settings Peak value Bottom value Delay time Piping Applicable fluid Series Output type Enclosure Copy function 1/4 (R, NPT, G) (URJ1/TSJ2) M5 female thread 1/8 (R, NPT) ZSE20(F)/ ISE20 1 output IP40 p. 9 ZSE20A(F)/ ISE20A 2 outputs Analog output (Voltage/Current) IP40
(No dustproof net is included.) w Replacement type dustproof filter HRS-FL002 5 filters per set Size: 300 x 370 w r Particle Filter Set Removes foreign objects in the circulating fluid.
R () () P.1-5 P.1-5 7122 20 335 752 670 IDFA100F150F 6 3 6.3 IDX-OM-U022 6.
Piping Applicable fluid Series Output type Enclosure Copy function 1/4 (R, NPT, G) (URJ*1/TSJ*2) M5 female thread 1/8 (R, NPT) ZSE20(F)/ ISE20 1 output IP40 U U p. 7 ZSE20A(F)/ ISE20A 2 outputs New New Analog output (Voltage/Current) IP40 U U Air p. 9 ZSE20B(F)/ ISE20B 2 outputs New New Analog output (Voltage/Current) IP65 U U U p. 11 ZSE20C(F)/ ISE20C(H) 2 outputs General fluids New
Applicable model Minimum operating flow rate (50/60 Hz) [L/min] HRS-BP005 HRS090-ll-20/40 29/45 To circulating fluid return port r t r e q To circulating fluid outlet r t w r Parts List No.
Applicable model Minimum operating flow rate [L/min] HRS-BP005 HRSH090-ll-l 20 r t r e q To circulating fluid outlet r t w r Parts List No.
20 25 32 40 Bore size (mm) MK(2) 32 Piston speed (mm/s) 0.5 to 300 40 0.27 0.4 0.65 1.2 Allowable kinetic energy (J) RS Q G Note) Other intermediate strokes can be manufactured upon receipt of order.
Compact / Lightweight 2 Port Solenoid Valve VDW30/40-XF Series For Air/Water Compact / Lightweight resin body (PPS) IP65 RoHS Weight: 120 g (VDW30-XF) n t r e y l d a i 30 mm c r e i r c e s l t e e c c t b t i Power consumption e e o n d l a n .
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-17 Connection of RS-232C HRSH Series 3.3Installation 3-25 HRX-OM-R026 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
25-MLA [ISE35-R-25-M (Switch body only)] NPN output / Wiring top entry Note 4) Digital type ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output / Wiring bottom entry ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] PNP output / Wiring top entry Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut
25-MLA [ISE35-R-25-M (Switch body only)] NPN output / Wiring top entry Note 4) Digital type ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output / Wiring bottom entry ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] PNP output / Wiring top entry Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut
r r r q w e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR30l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR30l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 800 Precision Regulator IR1000-A/2000-A/3000-A Series Dimensions Basic type (Knob): IR10l0-01l-A 10.5 42 ARJ 1.6 Bracket AR425 to 935 Mounting hole