Value Setting range 0 Based on the automatic setting (device minimum cycle time). 1 to 3 0.4 ms 4 to 63 0.4 ms to 6.3 ms (by 0.1 ms) 64 to 127 6.4 ms to 31.6 ms (by 0.4 ms) 128 to 191 32.0 ms to 132.8 ms (by 1.6 ms) 192 to 255 132.8 ms Values are calculated based on the following calculation.
When you use this system together with another product compatible with the gateway distributed system (64 points), please refer to the SMC website (URL http://www.smcworld.com) to obtain more detailed information about product. Switch protective cover Set up the IP address using the internal switches. 9 Grounding terminal (FE) Used for functional grounding.
Table for the change of parameter setting (wireless slave (1)) Setting items Set value Hold/Clear (unit) Clear Occupied points for the module input 64 point/8 byte Occupied points for the module output 48 points/6 bytes Occupied points for the valve manifold output 32 point/4 byte Wireless communication Active Analogue input update time 1 s I/O unit assignment direction Mode 1 (4) (3) Default
input unit (EX600-DX#D): 2 bytes occupied Output data: [Unit 0] Digital output unit (EX600-DY#B): 1 byte occupied [Unit 2] Wireless master unit (EX600-WEN#): 2 bytes occupied Unit 0 Unit 1 Unit 2 Unit 3 DY#B AXA DX#D EX600-WSV# Wireless slave unit setting parameter (Wireless channel 001) Valve End Digital output Analogue Digital Wireless slave manifold plate input input unit Input size: 64
Table for the change of parameter setting (wireless slave (1)) Setting items Set value Hold/Clear (unit) Clear Occupied points for the module input 64 point/8 byte Occupied points for the module output 48 points/6 bytes Occupied points for the valve manifold output 32 point/4 byte Wireless communication Active Analogue input update time 1 s I/O unit assignment direction Mode 1 (4) (3) Default
to 79 CH1: Measurement value With symbol 16 bit Bit offset 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 Item CH1: Measurement value Bit offset 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 Item CH2: Measurement value Bit offset 47 46 45 44 43 43 41 40 39 38 37 36 35 34 33 32 Item CH3: Measurement value Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4: Measurement
settings 34 F0 Selection of reference condition, unit selection function, switch output specifications 36 F1 Setting of OUT1 39 F2 Setting of OUT2 46 F3 Digital filter setting 52 F10 Sub screen setting 53 F14 Zero-cut setting 59 F20 Setting of external input 60 F22 Analogue output setting 61 F30 Accumulated flow value hold setting 62 F80 Display OFF mode setting 63 F81 Setting of security code 64
35 [F 2] Setting of OUT2 42 [F 3] Digital filter setting 48 [F10] Sub screen setting 49 [F14] Zero-cut setting 55 [F20] Setting of external input 56 [F22] Analogue output setting 57 [F30] Accumulated flow value hold setting 58 [F80] Display OFF mode setting 59 [F81] Setting of security code 60 [F90] Setting of all function 62 [F96] Check of input signal 63 [F98] Setting of output check 64
Product failure Replace the product 64 No.PF-OMU0002-D Error indication Problem Possible causes Investigation method Countermeasure (1) Check if the output current is 80 mA or greater. (1)(2) Connect the appropriate (2) Check if the connected load load. complies with the specification.
to 79 Accumulated flow rate lower limit Without sign: 32 bit 80 to 95 Accumulated flow rate upper limit Without sign: 32 bit Bit offset 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 Item Accumulated flow rate upper limit (PD) Bit offset 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 Item Accumulated flow rate lower limit (PD) Bit offset 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48
to 79 CH1: Flow measurement value With symbol 16 bit Bit offset 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 Item CH1: Flow measurement value (PD) Bit offset 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 Item CH2: Flow measurement value (PD) Bit offset 47 46 45 44 43 43 41 40 39 38 37 36 35 34 33 32 Item CH3: Flow measurement value (PD) Bit offset 31 30 29 28 27 26 25 24 23 22 21 20
Display units, units selection for accumulated flow, switch output specifications and diagnostic information selection function 34 F1 Setting of OUT1 37 F2 Setting of OUT2 45 F3 Digital filter setting 52 F10 Sub screen setting 53 F30 Accumulated flow value storage setting 59 F80 Display OFF mode setting 60 F81 Setting of security code 61 F90 Setting of all functions 63 F98 Output check 64
No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.
PV SV 5.19 Communication function HRS Series 5-64 HRX-OM-W038 Chapter 5 Display and setting of various functions 46. Select contact input signal 1 function from the table below with [] key or [] key, and confirm by pressing SEL.
HRL Series 5.4 Description of Screen 5-63 HRX-OM-W060 Chapter 5 Display and Setting of Various Functions 5.4 Description of Screen HRL Series 5-64 HRX-OM-W060 Chapter 6 Alarm Notification and Troubleshooting Chapter 6 Alarm Notification and Troubleshooting 6.1 Alarm Notification The product makes notification in the order shown below when any alarm is generated.
fluid discharge pressure sensor MT10 CH2 Flow Sensor Maintenance for CH2 circulating fluid flow sensor MT11 2 CH1 DI Filter CH1 DI filter maintenance (Option D1 only) 1 Refer to 5.4.5 Check operation time screen and maintenance reminder for Maintenance reminder. 2 In the case of option D1 "CH1 with electrical conductivity control", to display. 5.4 Description of the Screen HRL Series 5-64
. 1-15 1.7.1 Disposal of refrigerant and compressor oil. 1-15 1.7.2 Circulating fluid disposal. 1-16 1.7.3 System disposal . 1-16 1.7.4 Label . 1-16 1.8 Material Safety Data Sheet (SDS) . 1-16 1.8.1 Galden HT135 . 1-17 1.8.2 FluorinertTM FC-3283 . 1-29 1.8.3 Galden HT200 . 1-38 1.8.4 FluorinertTM FC-40 . 1-50 1.8.5 Ethylene glycol aqueous solution 60% . 1-58 1.8.6 Refrigerant R410A . 1-64
No.IP8S-OM09 64 < (C70) Span adjustment*31> Adjust zero point / span. Unlike automatic calibration of (C30), PID constant automatic setting is not performed. PID set once remains valid. This function is used when only zero-span adjustment is necessary.
Cylinder tube Piston rod Rod cover 64 (5) Remove the pipe from the pipe block (head side). (For 160 to 320. For 125, remove the piping from the head cover. Pipe block (Head side) Cylinder tube Pipe (6) Hold the piston rod and remove the piston assembly from the cylinder tube. Piston rod Cylinder tube Piston assembly (7) Remove the cylinder tube from the head cover.
Power supply connector Specification . 64 . I/O connector specification . 65 .. Details of parallel input/output signals . 65 .. Parallel input/output specification . 67 .. Parallel input/output type circuit (NPN and PNP specifications) 67 Setting . 68 . Operation data . 68 . Parameter . 70 Optional parts (sold separately . 72 . Power supply cable . 72 . I/O cable . 72 .