Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: DA (EtherCAT - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 4 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10 (Side-Ported), Connector Type: FW (D-sub Connector, IP67, 25 Pins), Connector Entry Direction: 2 (Lateral), Valve Stations: 6 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10 (Side-Ported), Connector Type: FC (D-sub Connector, IP20, 25 Pins, Compact Type), Connector Entry Direction: 1 (Upward), Valve Stations: 2 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 10 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: KA (IO-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 10 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10 (Side-Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable), Connector Entry Direction: 1 (Upward), Valve Stations: 5 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: WE [EtherNet/IPâ„¢ (Compatible Wireless Base)], SI Unit Common, End Plate: 4 (Power Supply w/M12 Connector, PNP), I/O Unit Stations: None, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 40 (Side Ported), Valve Stations: 4 Stations, P,E Port Entry: B (Both Sides), A,B Port Size: C6 (ø6 One-touch Fitting; Fixed)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 6 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Reduced apparent power 10 VA m 7 VA (Size 1) Normally Closed (N.C.)
/N.O. 0.51 0.26 0.7 0.51 0.23 1/8 Single Double Closed center Exhaust center Pressure center 2position Note) [ ]: Indicates normal position 1.5 0.33 0.33 2.0 0.37 0.52 1.3 0.39 0.31 0.32 0.33 1.6 C6 6 Onetouch fitting 3position 1.8 [1.4] 0.35 [0.37] 0.44 [0.35] Series 53-SY9000 1.3 0.33 0.33 53-SY5 20-C6 Port size Flow-rate characteristics 1.7 [0.80] 0.44 0.31 [0.47] 0.33 0.42 [0.23] 1.7
L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.
How to Order Manifold Assemblies (Example) How to Order Valves Example (SZ3000, positive common with power supply terminals) SZ3 5 1 C6 LOZ 60 Double solenoid SZ3260-5LOZ-C6 (3 sets) Single solenoid SZ3160-5LOZ-C6 (2 sets) Type of actuation Supply/Exhaust block (U side mounting) 1 2 3 4 5 A B C 2 position single solenoid 2 position double solenoid 3 position closed center Switch specifications
The solenoids are counted as Single : 1 point Double, 3P: 2 points Dual 3 port: 2 points Manifold mounting Symbol Mounting DIN rail mount type Direct mount type D E How to Order Valves 1 1 1 Y 5 B C6 Series SQ 3 Manifold block Specifications Without manifold block With manifold block With manifold block Built-in back pressure check valve Symbol Nil Note 1) SQ1000 SQ2000 1 2 M Note 2) Type
orientation Ceiling m Wall m Vertical m Note) Static load m Horizontal m M M m x g x X m x g x X m x g x Z M Static moment z y Y m x g x Y m x g x Y m x g x Z M Z m x g x X m x g x Y m x g M Note) m is a mass movable by thrust.
0.5 m 1 m 3 m 5 m Socket side: Straight Plug side: Straight 010 050 1 m 5 m SSPS Socket side: Angle Plug side: Angle SAPA Connector specifications S A Straight Angle Cable core wire colors Terminal no.
Port size Body style Port size One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 10 One-touch fitting for 12 VQ20 VQ30 Symbol C6 C8 C10 C12 A: Single unit Manual override None M: For manifold B(1) Locking style (Slotted) Note 1) Only normally closed DIN connector in-line style is possible.
s2 / 90 m/s2 P7, P10 (Quick fastener) C4, C6, C8, C10 (One-touch fitting) Port size Orifice diameter 1, 3, 4.5, 6 Rated voltage 24 VDC, 12 VDC 10% of rated voltage Allowable voltage fluctuation Coil insulation type Class B 500 VDC, 10 M or more Insulation resistance Voltage limit 1800 VAC, 1 sec., 3 mA or less Simulation noise: 500 Vp-p (Based on 1 sec. pulse width, 50 10 Hz frequency noise