SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-V-M-01-W"

Other parameter settings Front protective cover (Model: ZS-26-01) Normal operation mode Item Default setting Item Default setting [F80] Power saving mode OFF [F 3] Digital filter setting [F 4] Auto-preset function [F 5] Auto shift setting [F 6] Fine adjustment of display value 0.00 sec.

R 2 1 1 0 01 01 Rc 1/8 N01 NPT 1/8 F01 F01 2 G 1/8 9 5 VR 1 ON Delay 0.560 () () 1 ON OFF 6 (1) 2 0.5MPa 2 10 (2) VR2110 3 )0.25MPa A 60sec (), (S) 0.8MPa 40sec B (3) (MPa) 3 OFF 1)4 1) OUT 0.7 0.6 VM1 VM1 () 0.5 0.4 0.3 0.2 ,0.6MPa VM2 VM2 0.1 ,0.3MPa 2 0 1 2 3 4 5 6 7 8 9 10 (m) 4 11 7. 4 (EXH) 1/8 (PIL) R 3 (R) 21/8 2 (A) 1 (P) 2M61 8 () 2x6.5 M6x1x12 4xM6 4X7

Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)

Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)

Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: (None), Exhaust Solenoid Valve: V (V124-5LU-M5)

Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: (None), Exhaust Solenoid Valve: V (V124-5LU-M5)

Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: (None), Exhaust Solenoid Valve: V (V124-5LU-M5)

Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: C4 (ø4), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 1C (1 + C), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: Rc, Port Size: 01 (1/8), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: CG (C + G), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: CG (C + G), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

24V 0V 0V (2) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (LEC)OFF 22 - 7.CN3 1 2 3 4 5 TM() 1 VDeviceNet 2 CAN_L CAN(L) 3 SHIELD 4 CAN_H CAN(H) TM() 5 V+ DeviceNet DeviceNet TMCAN_HCAN_L 1201% 1/4W 23 - 8.CN1IF(CONT) 8.1 (LEC)8 LEC-CG1-1LEC-CG2-1 LEC-CG2b) M12 4pin b) M12 4pin LEC-CGD LEC-CGD LEC-CGR c) M12 4pin LEC-CG1b) M12 4pin b) M12 4pin