Bore size 40 mm (1-1/2) 50 mm (2) 63 mm (2-1/2) Stroke Hundredths of an inch* 20 25 32 40 50 63 20 mm (3/4) 25 mm (1) 32 mm (1-1/4) Stroke length must be indicated as 4 digits.
0 10 20 30 40 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] 1,000 1,000 1,000 Mey L2 [mm] m 500 500 500 L2 0 0 0 0 5 10 15 20 0 10 20 30 40 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] 800 800 800 600 600 600 L3 L3 [mm] 400 400 400 Mer m 200 200 200 0 0 0 0 5 10 15 20 0 10 20 30 40 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] 82
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
Power supply cable (LEC-CK1-1) is an accessory.
Standard stroke (mm) Bore size 12, 16 20, 25 Standard stroke 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Double acting Action D Built-in Magnet Cylinder Model If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.
10-20-59 With built-in OFF-delay timer (200 ms) CE1 D-G5NTL D-F7NTL D-F5NTL D-M5NTL/M5PTL 10-20-60 Grommet Band Solid state switch With timer 10-20-61 Grommet Rail CE2 10-20-62 Grommet Tie-rod 10-20-63 Grommet Direct ML2B Possible to use in an environment where disturbance magnetic fields are generated.
mA, 4 to 20 mA 12 bit resolution Input signal range 10 to 10 V, 5 to 5 V 20 to 20 mA 16 bit resolution EX600-AXA 15 V 22 mA Note 2) Max. rated input signal 50 100 k Input impedance 0.05% F .S.
Dimensions ZP2-Z002 ZP2-Z003 40 20 0.1 0.2 A A 20 0.1 0.2 40 A A 20 40 A-A A-A w q q w 11 20 9 18 90 4 x 4 90 4 x 4 4 e e 5 5 () 12 () 4 x 2.4 1.8 1.5 4 x 2.4 1.5 0.9 20 9.4 Component Parts Component Parts Part no. Description No. ZP2-Z2A ZP2-Z2B ZP2-Z2C Material PTFE FKM Aluminum alloy Note Clear anodized Part no. Description No.
25 REAH15, 20, 25 REAH15, 20, 25 REAH15, 20 REAH15, 20 REAH25 REAH15, 20 REAH25 High Precision Guide Type REAH 0.08 Deflection (mm) Deflection (mm) Deflection (mm) Deflection (mm) 0.03 REAH25 0.02 0.06 0.02 0.04 0.01 0.01 0.02 Max.
HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250-W-20/40. 8-17 8.5 Pump Capacity . 8-18 8.5.1 HRSH100-A-20/40-, HRSH100-W-20/40. 8-18 8.5.2 HRSH150/200-A-20/40-HRSH150/200/250-W-20/40. 8-18 8.5.3 HRSH250/300
Bore size 6 10 16 20 25 32 6 mm 10 mm 16 mm 20 mm 25 mm 32 mm Built-in Magnet Cylinder Model Action If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.
For details, refer to pages 3-7-19 and 3-7-20.
With buffer 04 06 4 6 Vacuum inlet direction Direction Lateral Symbol Buffer stroke ( ) R Pad size Symbol Stroke Pad type Buffer specification 10 20 30 40 50 10 mm 20 mm 30 mm 40 mm 50 mm Symbol Size 3.5 x 7 4 x 10 5 x 10 6 x 10 4 x 20 5 x 20 Symbol Size 6 x 20 8 x 20 4 x 30 5 x 30 6 x 30 8 x 30 Symbol Specification 3507 4010 5010 6010 4020 5020 6020 8020 4030 5030 6030 8030 Symbol W Type
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
(Conforming to DIN) Clip Without indicator light AXT100-20-1 Rated voltage With indicator light 16.8 Voltage symbol Part no. AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 13.8 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V 1. It is able to change the cylinder port between side ported and top ported.
, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 12 16 20 25 CQM MU 12 16 5, 10, 15, 20 25, 30 20 25 5, 10, 15, 20, 25 30, 35, 40, 45, 50 Double rod CQSW 560 12 16 20 25 5, 10 Double acting Single acting Return/Extend CQS 567 12, 16 20, 25 Non-rotating Rod Single rod CQSK 575 12 16 5, 10, 15, 20 25, 30 20 25 5, 10, 15, 20, 25 30, 35, 40, 45, 50 Double rod CQSKW 582 Anti-lateral Load
(REH/Linear guide type) Series REAL Size: 10, 15, 20, 25, 32, 40 To ensure a permanent path When smoother operation is required, even with an offset load Stable operation is possible, even with an offset load, by using ball bushings. Series REAH Size: 10, 15, 20, 25, 32 The use of a linear guide facilitates a large load, large moment.
m (kg) Load weight m (kg) 20 20 20 20 20 20 16 16 16 16 16 16 1 1 12 12 12 12 12 12 0.5 10 20 30 31 50 100 101 300 200 0.5 10 20 30 31 50 100 101 300 200 Stroke (mm) Stroke (mm) MGPL32 to 63 MGPL32 to 63 50 50 Load weight m (kg) Load weight m (kg) 63 63 50, 63 50 50 50, 63 50, 63 10 10 40 40 40 50, 63 40 40 40 32 32 32 32 32 32 5 10 20 30 50 40 51 100 101 300 200 5 10 20 30 50 40 51 100
Select an air-hydro cylinder in combination with an air-hydro unit. Since good operation of an air-hydro cylinder depends on combination with an air-hydro unit, be sure to select an appropriate air-hydro unit. 2. Set the air-hydro cylinder's load at 50% or less of its theoretical output.
EMO circuit An EMO (EMergency Off) circuit is an electrical circuit provided to shut off all power and ensure safe conditions when an emergency stop button (EMO button) is pressed in an emergency. Hardware interlock This is an equipment control circuit for shutting off power in case of trouble.