Search Results "HEC002-A5B-FN"

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch.  Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility.  Designed to work with fluids up to 90ºC

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: J (Instantaneous Flow: L/min, Accumulated Flow: L, Temperature: Â

s Peltier device is that both noise and vibrations are kept to an absolute minimum.Can control the temperature of a heat source or process fluid , Air-cooled, Compliant with safety standard for medical equipment IEC 60601-1 (HEC002-A series) , Power supply: Applicable to 100V to 240V , Circulating fluid suitable to clear water, THERMO-CON, AIR COOLED, OTHERS, HEC THERMO CONTROLLER, 1X

s Peltier device is that both noise and vibrations are kept to an absolute minimum.Can control the temperature of a heat source or process fluid , Air-cooled, Compliant with safety standard for medical equipment IEC 60601-1 (HEC002-A series) , Power supply: Applicable to 100V to 240V , Circulating fluid suitable to clear water, THERMO-CON, AIR COOLED, OTHERS, HEC THERMO CONTROLLER, 1X

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HEC OTHER SIZE(MISC./OTHER), OTHERS, HEC THERMO CONTROLLER, 1X, HEC OTHER SIZE(MISC./OTHER), 1.1 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HEC OTHER SIZE(MISC./OTHER), OTHERS, HEC THERMO CONTROLLER, 1X, HEC OTHER SIZE(MISC./OTHER), 1.1 lb

Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications

Stations: 05 (5 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications

Stations: 05 (5 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications

Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: F (G), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: F (

Stations: 3 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 0.5 to 4 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow

Stations: 5 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow

Stations: 5 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate

Stations: 3 Stations, Piping: U Side: Open; D Side: Open, Thread Type: G, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 5 to 40 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 3/4, Return Unit Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate: Analog

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Stations: 08 (8 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead

HEC OTHER SIZE(MISC./OTHER), OTHERS, HEC THERMO CONTROLLER, 1X, HEC OTHER SIZE(MISC./OTHER), 66.91029 lb, ModelCooling methodRadiating methodControl methodAmbient temperature/humidityCirculating fluid systemElectrical systemWeightAccessoriesSafety standardsCirculating fluidOperating temperature rangeCooling capacityHeating capacityTemperature stability Note 3)Pump capacityTank capacityPort