Grade 2 Grade 2 Rubber stopper Grade 4 Grade 4 Metal stopper Auto switches / Proper mounting position for stroke end detection 11-/22MXP6 A A C D D B Reed switch D-A93 Solid state switch D-M9B, D-M9N Stroke (mm) Auto switch operating range 10 34.5 35.5 14.5 15.5 Stroke (mm) Auto switch operating range 10 30.5 31.5 18.5 19.5 Model Model 5 25.5 26.5 13.5 14.5 A B C D A B C D 11-/22-MXP 6
Table 3-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of 3 C between inside Differential temp. of 6 C between inside radiation Model (kW) and outside of and outside of installation area installation area HRR050-A-20/40Approx.10 140 70 3.2 Installation HRR Series 3-4 HRX-OM-X071 Chapter 3 Transport and Setting Up The water cooled
Note Conductor resistance /km, 20C 65 or less 1.5 m 3 m 5 m AXT100-DS25-015 10 Cable 25 cores x 24AWG AXT100-DS25-030 Voltage limit VAC, 1 min. 1000 AXT100-DS25-050 L For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. Note) The min. bending radius of D-sub cable is 20 mm.
Types 10, 20 Types 10, 20 VVDW 0 2 C 1 01 2 VVDW 2 0 4A Series Series 1 2 10 20 Thread type 1 2 10 20 Rc G NPT Nil F N Material Brass Stainless steel C S Type 30 OUT port size Stations VVCW20-4A Symbol M5 01 Port size M5 1/8 (6A) For 2 stations For 3 stations 1 2 Type 10 is M5 only.
4 C-9 MYM50-15AK0502 GMY50 MC-16 P44 C-4 C-11.2 MYM63-15AK0503 GMY63 MC-20 P53 C-4 C-14 GMY20 GMY16 GMY25 GMY32 MYB20-15-A7164 MYB16-15-A7163 RCS-8 RCS-10 P16 P12 TMY-25 TMY-32 5.1 x 3 x 1.05 4 x 1.8 x 1.1 7.15 x 3.75 x 1.7 8.3 x 4.5 x 1.9 7 x 4 x 1.5 7 x 4 x 1.5 C-6 C-7 MYMK-20-stroke Side seal assembly Polyurethane MYMK-16-stroke MYMK-40-stroke MYMK-25-stroke MYMK-32-stroke Note) Two
L A B C Lead 20 10 5 2.86 20 10 5 Parameter *1,*2 Para.
7-1 . 7-1 7-2 . 7-1 8 L 8-1 . 8-1 8-2 . 8-1 8-3 . 8-2 8-4 . 8-2 9 M 9-1 . 9-1 9-2 . 9-1 9-3 . 9-2 9-4 . 9-2 10 R 10-1 . 10-1 10-2 . 10-1 10-3 . 10-2 10-4 . 10-2 10-5 . 10-2 11 T 11-1 . 11-1 11-2 . 11-1 11-3 . 11-1 11-4 . 11-2 11-5 . 11-2 11-6 . 11-3 12 V 12-1 . 12-1 12-2 . 12-1 12-3 . 12-2 12-4 . 12-2 13 13-1 . 13-1 2 i IDX-OM-W029 i i-1 () OFF 3 ON
C76 Option Compatibility C85 NCM Standard C95 NCM-K NCM-J NCMW NCDM NCMK XB6 XB7 XB9 XC6 Description Note C S T CP95 NCM NCM NCDM NCMW NCMK NCM-J NCM-K S T C XB6 XB7 XB9 XC6 B C E R O O O O O O O O O O O O O O O O Standard Auto switch capable Double rod Non-rotating Nylon rod boot Neoprone rod boot Spring return Spring extend Rubber bumper Heat resistant Cold resistant Low speed Stainless
F (LC6D-2 only) +24V GND CW+ CW CCW+ CCW PD+ PD A B C D E 7 6 3 10 CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.
/11-CUJ Mini-free mount cylinder Dimensions 6 to 10 -C(D)UJB 10 11 Without magnet Note1) The angular position of the width across flats with respect to the tube is not fixed.
(mm) TLM0201 2 x 1 2 1 TLM0302 3 x 2 3 2 TLM0425 4 x 2.5 4 2.5 TLM0403 4 x 3 4 3 TLM0604 6 x 4 6 4 TLM0806 8 x 6 8 6 TLM1075 10 x 7.5 10 7.5 TLM1008 10 x 8 10 8 TLM1209 12 x 9 12 9 TLM1210 12 x 10 12 10 TLM1916 19 x 16 19 16 TLM2522 25 x 22 25 22 TLM1613 16 x 13 16 13 Length per roll Color Translucent Translucent Symbol N N R BU B N N N 10 m Red (Translucent) 20 m Blue (Translucent) Roll
ZS-28-C ZS-28-C-1 ZS-28-C-2 10 pcs./pack ZS-28-C-P ZS-28-C-1P ZS-28-C-2P Red 0.8 to 1.0 AWG26 to 24 0.14 to 0.2 mm 2 Yellow 1.0 to 1.2 w Press with pliers. 10 seconds for 4 cables. Note) Applicability varies dependant on conductive construction, conductive material, and/or insulating material even resulting in inapplicable. Consult with P/A and manufacture of connecting equipment.
R2 port) 17.5 14 28 L plug connector (L): SYJ3 40-L-M5 M plug connector (M): SYJ3 40-M-M5 M8 connector (WO): SYJ3 40(R)-WO-M5 3 4 5 3 4 5 3 4 5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 55.8 32.6 49.3 111.5 [115.9] R1 P R2 R1 P R2 R1 P R2 91.9 [96.3] 10 10 10 10 10 10 28 28 28 109.7 14 14 14 5 5 5 37.6 [39.8] 47.4 [49.6] 39.1
*10 *10 *10 *10 *10 *7 For pipe thread type: NPT.
1 C 6 2 1 3 G1/8 F 3 G1/8 7 NPN1 PNP1 N P L 4 7 5 M SI N 1 2 3 4 5 6 1 2 S 6 7 8 3 4 5 6 6 7 8 T 1F 2GH 3ISO1179-1 4 5kPa 61 7 88 (10 ) 9DIN 101 1 2 2 -8No.PS-OMR0001CN-J 2 B 2 F 0.010.03mm 0.020.15mm 0.050.30mm G H DC24V AC100V AC110V 10 1 10 2 Rc1/8 4 1 C 2 10 N 6 10 3 0 G1/8 F G1/8 3 0.4MPaMPa 1 11 0.4MPaMPa 2 0.2MPaMPa C Rc1/4 3 F 12 G1/4 0.2MPaMPa 4
Allowable voltage fluctuation is 10% of the rated voltage.
Please refer to Auto drain replacement on P14 for removal of the auto drain. -10- Doc. no. AMX-OMU0058-C 2.
Range Resolution LAT3-10 0 to 10 Refer to the 0.03 LAT3-20 0 to 20 Area Range table on the LAT3-30 0 to 30 right. LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds the 0.5 to 5.0 set value.
All types are equipped with surge voltage suppressor. 17-2-10 5 Series VCA Direct Operated 2 Port Solenoid Valve For Air Standard Specifications Valve construction Direct operated poppet Fluid Air, Inert gas, Low vacuum (133 Paabs) Withstand pressure (MPa) 2.0 Body material Al Seal material HNBR Valve specifications Ambient temperature (C) 20 to 60 Fluid temperature (C) 10 to 60 (No freezing
Q Approx. 300 F D Approx. 280 D Q F C G (PF) 1/2 C R R E E B A H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.