this point is approximately 0.4 MPa. 0.7 0.7 0.7 SUP = 0.7 MPa 0.6 0.6 0.6 Discharge pressure (MPa) Discharge pressure (MPa) Discharge pressure (MPa) SUP = 0.7 MPa SUP = 0.7 MPa SUP = 0.5 MPa 0.5 0.5 0.5 SUP = 0.35 MPa SUP = 0.5 MPa SUP = 0.5 MPa SUP = 0.2 MPa 0.4 0.4 0.4 SUP = 0.35 MPa SUP = 0.35 MPa 0.3 0.3 0.3 SUP = 0.2 MPa SUP = 0.2 MPa 0.2 0.2 0.2 0.1 0.1 0.1 0 0 0 50 100 150 200 250 500
Rod Couplers Part # Rod Thread DMA-312 5 16-24 DMA-375 38-24 DMA-437 7 16-20 DMA-500 12-20 The Table on the right shows the Rod Couplers that offers. The thread shown is a male / female thread as the coupler has both a male and female end.
500 1000 1500 Flow rate L/min Flow rate L/min (ANR) Flow rate L/min (ANR) SRH4100-03 SRH4110-03 SRH4100-03 0.5 0.20 0.20 0.4 Outlet pressure MPa Outlet pressure MPa Outlet pressure MPa 0.15 0.15 0.3 0.10 0.10 0.2 0.05 0.05 0.1 1000 500 10 5 0 15 20 25 500 1000 1500 0 0 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min 858 Clean Regulator SRH Series Pressure Characteristics (Representative
Rod Couplers Part # Rod Thread DMA-312 5 16-24 DMA-375 38-24 DMA-437 7 16-20 DMA-500 12-20 The Table on the right shows the Rod Couplers that offers. The thread shown is a male / female thread as the coupler has both a male and female end.
TUB-20 Series PEAPP Series PEAPP Polyurethane Tubing How to Order PEAPP 07 BU 153 Linear low density polyethykene tubing, Industrial grade Length per roll Length 100 (33m) 250 (100m) 500 (153m) 1000 (305m) Symbol 33 100 153 305 Tube O.D.
Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB, CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Average speed Series (mm/s) VQC 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SQ VQ0149-C4 VQ0 VQ4 800 700 600 500 400 300 200
DIN rail mount type and box mount types are available. 587 PC Wiring System e-con Type Series PCW-EC Common Specifications Rated voltage 24 VDC Power supply line 2 A Rated current Communication line 0.3 A Insulation resistance 5 M or more at 100 VDC Withstand voltage 500 VAC Impact resistance 500 m/s2 Screw tightening torque (Phillips head screwdriver/flat head screwdriver) 0.4 to 0.6 Nm/
280 560 10 4 8 7 6 5 MXY12 3 2.0 Shock absorber Rubber stopper screw 2 4 Load mass W kg 1.5 Metal stopper screw 3 1.0 1 100 50 200 300 400 560 2 100 50 200 300 400 500 Average speed Va mm/s Collision speed V mm/s 0.5 Average speed Va mm/s 0.0 Collision speed V mm/s 0 100 200 300 400 500 280 560 Note) Use the average speed when calculating static moment.
Refer to page 25 for Table of Mountable Units. 10 Series EX600 SI Unit Specifications All Units Common Specifications Operating temperature range 10 to 50C Storage temperature range 20 to 60C Operating humidity range 35 to 85% RH (No dew condensation) Withstand voltage Note) 500 VAC for 1 minute between external terminals and FE Insulation resistance Note) 500 VDC, 10 MW or more between external
Select after confirming interface with such as work pieces. t Stroke [mm] w Motor mounting position 30 Top mounting type Right side parallel type Left side parallel type In-line type 30 Nil R L D 500 to to 500 Refer to the applicable stroke table. u Rod end thread e Motor type Rod end female thread Nil Symbol Type Size Compatible controller Rod end male thread (1 rod end nut is included.
Standard Strokes Bore size [mm] Standard stroke [mm] Note 1) Long stroke [mm] Note 2) 40 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500 800 Refer to pages 18 to 23 for cylinders with auto switches. 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500, 600 1200 Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at
50, 100, 150, 200, 250, 300 10 15 20 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 1000 1500 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke specification (XB11) applies to the strokes exceeding 2000 mm.
75, 100, 125, 150, (Band and screw are included.) 32 350, 400, 450, 500, 600 Ball bushing bearing MLGCL 200, 250, 300 Bore size (mm) Auto switch model D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700, 800 20 25 32 40 BMA2 -020 BA -01 BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon
, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80: 1400 100: 1500 Refer to pages 19 to 23 for cylinders with auto switches. 80, 100 Intermediate strokes not listed above are produced upon receipt of order.
50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63 63 Note 1) Stroke exceeding
Bore size (mm) Standard stroke (mm) Note 1) Long stroke (mm) Note 2) Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at stroke end) and mounting height Operating range Auto switch mounting bracket/Part no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
VAC for 1 min. between external terminals and FG 10 M or more (500 VDC) between external terminals and FG Branch cable length Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance Vibration resistance Impact resistance Note 1) Please note that the version is subject to change.
500 M Rod end male thread (1 rod end nut is included.)
Please contact SMC in this case. 392 Guide Cylinder/Compact Type Series MGC JIS Symbol Specifications Standard Stroke Model (Bearing type) Bore size (mm) Standard stroke (mm) Long stroke (mm) 20 75, 100, 125, 150, 200 250, 300, 350, 400 25 350, 400, 450, 500 MGCM (Slide bearing) 32 350, 400, 450, 500, 600 75, 100, 125, 150, 200, 250, 300 350, 400, 450, 500, 600, 700, 800 MGCL (Ball bushing