SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2F40-50-D-M9PSDPC"

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 750, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 900, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: M9P, Lead Wire Length

Double acting, single rod cylinder w/lock, Mounting: basic, axial foot, rod flange, head flange, single clevis, double clevis, center trunnion, Bore sizes (mm): 40, 50, 63, 80, 100, Strokes up to 1500mm (depending on bore size and mounting), Auto switch capable, 40MM CNA DBL ACTING, AUTO-SW, ACTUATOR, CNA/CNA2 POWER LOCK CYLINDER, ME, 40MM CNA DBL ACTING, AUTO-SW, 5.58504 lb

Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: None, Lead Wire or Prewired Connector: 0.5m (Or None - See Series Catalog), Option: w/o Indicator Light for Dark Room

Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: None, Lead Wire or Prewired Connector: 0.5m (Or None - See Series Catalog), Option: 50 (w/o Indicator Light for Dark Room)

Double acting, single rod cylinder w/lock, Mounting: basic, axial foot, rod flange, head flange, single clevis, double clevis, center trunnion, Bore sizes (mm): 40, 50, 63, 80, 100, Strokes up to 1500mm (depending on bore size and mounting), Auto switch capable, CYL, TIE ROD, POWER LOCK, A/S, ACTUATOR, CNA/CNA2 POWER LOCK CYLINDER, ME, 40MM CNA DBL ACTING, AUTO-SW, 5.29109 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM CNA DBL ACTING, AUTO-SW, ACTUATOR, CNA/CNA2 POWER LOCK CYLINDER, ME, 40MM CNA DBL ACTING, AUTO-SW, 6.17294 lb