Search Results "CDNA2F100TN-400-D-M9PSDPC"

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 900, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Product Outlines 2. 1 How to Order L A T F D I/O cable specification Card Motor NIL Standard product X152 I/O cable (without Sensor resolution Note1) shield)Note4) NIL 30m M 5m Controller mounting method F 1.25m NIL Screw mounting type D Note3) DIN rail mounting type Stroke Note1) I/O cable length Note2) 10 10mm NIL Without cable 20 20mm 1 1m 30 30mm 3 3m 50 50mm 5 5m Actuator cable length

Switches P: Operating pressure (PSI) V: Speed (inch/s) Stroke (inch) Mode of operation (horizontal, inclined, vertical) Mode of operation Note 1) Inclined operation Vertical operation Horizontal operation Review of load weight and operating pressure W Lo Guide First tentative bore size determination F1 D 1.6 x P First tentative bore size determination F2 D 1.6 x P First tentative bore size

For the D-P3DW;, refer to the catalog CAT.ES20-201. The D-A9;/M9;;;/P3DW; auto switches are shipped together, (but not assembled).

D-DN This catalog is printed on recycled paper with concern for the global environment.

Inch size ARJ310F-N01 5/32" 1/4" 03 07 14-4-11 Series ARJ310 Flow Characteristics Inlet pressure: 0.7 MPa ARJ310-01 ARJ310F-01-04 ARJ310F-01-06 0.7 0.7 0.7 0.6 0.6 0.6 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate

600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 0 0 0 0 Installation distance [mm] 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance [mm] 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance [mm] Installation distance [mm] Installation distance [mm] Installation distance [mm] IZF10R

Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.

Enter together in order, counting from station 1 on the D side.

Auto switch Mounting B L F G C D T Basic Axial foot Front flange Rear flange Single clevis Double clevis Center trunnion Tube material Nil F Aluminum tube Steel tube Nil Without auto switch Select an applicable auto switch part number from the table below. D-Z7, Z80, Y59, Y69, and Y7 are not mounted and are supplied loose.

Reduced outgassing o u Resin materials eliminated Laser marking is employed for the model designation. d t g e a c 2 s u s d i e Reduction of outgassing due to surface treatment n o u d t R g g e a c 1 s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.