SMC Corporation of America
Elite Part Number Search
Search Results "AS3001FG-08-J"

Stations: 08 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: R (Pressure Switch for Vacuum w/Energy Saving Function, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: W (Energy Saving), Unit Options: J (Vacuum Break Flow

Type: Speed Controller, Body Material: [Resin] Resin, Control Method: Meter-Out, Format: [Elbows] Plug-In Type, Environment, Applications: Standard, Knob Type: Resin, Lock Nut Option: Round Shape Lock Nut, Joint Type: Others, Applicable Tube O.D. mm(mm): 8, Body Size: 03 Standard

Suitable for applications where copper free specifications are required, the in.ûFGin. series can also be used in areas where wash down could degrade standard flow controls, such as food and packaging. This series is designed to offer the maximum control by increasing the number of turns of the needle to 10. The body and adjustment are made of high impact white resin for a clean look. This

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, SI Unit Only, Valves/Switch for Vacuum Conn. Specs.: Common Wiring, Plug-in for Manifold, Vacuum, V Port

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: Common Wiring

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: Common

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Pressure Sensor, 0 to -101, Analog Output 1 to 5 V, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size, ø8 One-touch Fitting

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, NPN 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: Common Wiring, Plug-in for Manifold,

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch