SMC Corporation of America
Elite Part Number Search
Search Results "AQ3000-03-H"

BM Bellows type with groove UM Flat type with groove KJH C2 06 Pad diameter Applicable tubing O.D. 63 63 80 80 04 4 06 6 03 5/32" 07 1/4" When changing the pad diameter, replace also the plate together. !

H (Conduit terminal: T) VXA I (DIN terminal: D) VN Main port Rc A H I J K L M R B F G N S C P T D Q U E Model LVC VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 52 2.3 42 26 25 28 4.5 34 14 72.5 80.5 74.5 79.5 82.5 124 125.5 142.5 24.3 55 LVA 60.5 73 1 80 90 84 100 92 108 62 72 2.3 2.3 50 60 31 36 30 35 35 40 5.5 6.5 43 49 17.5 20 83.5 89.5 88.5 94.5 91.5 97.5 135.5 151.5 137 153 154

H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 144.5 55 125.5 52 42 26 29 4.5 14 24.3 72.5 2.3 80.5 25 75 34 80 84.5 124 135.5 151.5 137 153 156 172 60.5 73 1 80 90 62 72 50 60 31 36 35 40 5.5 6.5 17.5 20 28.3 33.3 84 100 2.3 2.3 92 108 30 35 84 90 43 49 89 95 93.5 99.5 Port

Applicable bore A 0.51 D C 1/4-28 UNF B 0.16 JM-025 0.44 3/4", 7/8" JM-03 0.50 0.19 5/16-24 UNF 0.50 1 1/16" JM-045 0.69 0.79 0.26 7/16-20 UNF 1 1/4", 1 1/2" JM-04 0.56 3/8-24 UNF 0.65 0.23 1 1/4", 1 1/2" (Non-rotating) JM-05 0.75 1/2-20 UNF 0.32 0.87 2" 6-14-20 21 Series NCM Mounting Bracket Accessory Material: Rolled steel P dia.

Material H Color For mounting Cross recessed head countersunk tapping screw (Black zinc chromated) D Model No. of tubings Size (Nominal x Length) MS Model Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com No. of connecting tubes (Max.) 8 6 12 Applicable tubing O.D.

X17 P.69 Port size X26 P.70 Symbol Size 2C Applicable body size Accessory Option 3 4C 8C 11C 22C Symbol Nil Description Symbol Nil Description 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 B Bracket 2 Rubber material: Fluororubber For medium air pressure (1.6 MPa) Drain guide 1/4 female threaded 4 F H J R S U T V 2 Bracket is included, (but not assembled).

Description AMJ3000 AMJ4000 AMJ5000 AMJ-EL3000 AMJ-EL4000 AMJ-EL5000 Element assembly w AMJ-CA3000AMJ-CA4000AMJ-CA5000Bowl assembly Note) e 111512 111636 111636 NBR O-ring r 111710 NBR O-ring t Note) Refer to the above for How to Order Bowl Assembly. 13-13-4 5 Drain Separator for Vacuum Series AMJ Dimensions AMJ3000/4000 L F A Bracket (Option) G K M D J C E H H OUT IN ZX ZR 2port size

Steel) IP300 . 1P3100 DIMENS'ONS MODEL 1P300 (Lever Type) tu O O r o r n N ^ " n o r7a <6,69) (LEVER TYPE) MODEL 1P3100 (Rotary Type) O N / (2) t/4 t,tPt J o o iJ5 [8 so]]NVOLUTE SPL]NE 5HA:T 4 9 2 1 [ 1 2 s 0 0 ] r r81 lJ oool oo zzo fr ool r 1 3 T H P U H O I E S \ \ o o L O O N 0 945 I 24 001 2 7ss [7r oo] N O World Wide Ag{C Support...

Steel) IP300 . 1P3100 DIMENS'ONS MODEL 1P300 (Lever Type) tu O O r o r n N ^ " n o r7a <6,69) (LEVER TYPE) MODEL 1P3100 (Rotary Type) O N / (2) t/4 t,tPt J o o iJ5 [8 so]]NVOLUTE SPL]NE 5HA:T 4 9 2 1 [ 1 2 s 0 0 ] r r81 lJ oool oo zzo fr ool r 1 3 T H P U H O I E S \ \ o o L O O N 0 945 I 24 001 2 7ss [7r oo] N O World Wide Ag{C Support...

Cabl6 conneclion threads Solenoid valve EXH ---"-': 4 x l v s x 0 . 8 l h r e a d lrounling hole L-bracket series ITV 1 000/2000/3000 Made to Order Specifications Contact SMC regarding detailed dimensions, specifications and delivery times. Fluoro rubber is used for the rubber parts o{ seals.

M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS

Under certain circumstances, the use of an electronic type pressure gauge is recommended. 22 0 0 43.5 58 72.5 87 101.5 Supply pressure (psig) 142 Return to Menu Specialty Regulators NARM Series Regulator for Manifold NARM1000, 2000 Dimensions Dimensions Symbol A B C D E F G H J K M P Q R Model NARM1000 .18 .98 1.34 .83 .71 2.20 .63 .35 .71 .75 2.05 .35 .45 .19 (4.5) (25) (34) (21) (18) (

Flat Ribbon Cable Type 21P Applicable solenoid valve How to Order 1 3 5 6 4(A), 2(B) port Stations VV4Z1 05 21P VZ1120MOZ-M5 Applicable blanking plate assembly DXT170-25-3A Applicable connector assembly DXT170-127-A 1: 100 VAC, 3: 110 VAC, 4: DC P, R port thread type 03 3 stations 3(R) port Nil Rc G NPT 12 00F 12 stations 00N Refer to page 3-3-7 regarding how to order applicable connector

B and H cannot be selected at the same time. The current bracket cannot be used for this product. Note 2) Assembly of a bracket and set nuts. Note 3) See pressure unit table below.

H Clean One-touch fittings D MS Applicable tubing O.D.

M M5 M5 x 0.8 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection H/DL L/LL KC Applicable tubing O.D. Same dia. tubing 4 6 8 10 12 04 06 08 10 12 4 6 8 10 12 KK Tubing (rod) connection Different dia. tubing (plug-in reducer) KK130 DM Construction KDM KB KR KA KQG2 KG KFG2 MS KKA M5 type Male connector KP KP Description Material Component Parts LQ No.

Description AMJ3000 AMJ4000 AMJ5000 AMJ-EL3000 AMJ-EL4000 AMJ-EL5000 Element assembly w AMJ-CA3000AMJ-CA4000AMJ-CA5000Bowl assembly Note) e 111512 111636 111636 O-ring NBR r 111710 O-ring NBR t Note) Refer to the above for How to Order Bowl Assembly. 13-13-4 Drain Separator for Vacuum Series AMJ Dimensions AMJ3000/4000 L F A Bracket (Option) G K M D J C E H H OUT IN ZX ZR 2port size Drain

AW*-OMF0053-A PRODUCT NAME MICRO MIST SEPARATOR REGULATOR MODEL/ Series AWD20-(F,N)01(F,N)02(B,C,E,G,H)(-1,2,6,C,J,N,R,Z) AWD30-(F,N)02(F,N)03(B,C,D,E,G,H)(-1,2,6,8,J,N,R,W,Z) AWD40-(F,N)02(F,N)04(B,C,D,E,G,H)(1,2,6,8,J,N,R,W,Z) Contents PAGE 1. SAFETY INSTRUCTIONS 15 2. APPLICATION 6 3. SPECIFICATIONS 6 4. HOW TO ORDER 6 5. MAXIMUM APPLICABLE FLOW RATE 7 6.

B and H cannot be selected at the same time. The current bracket cannot be used for this product. Note 2) Assembly of a bracket and set nuts. Note 3) See pressure unit table below.

AC200V 200V SY100-61-2-02 AC110V 110V SY100-61-2-03 Dimensions are the same as type D DIN connector. AC220V 220V SY100-61-2-04 When replacing only the pilot valve assembly, V115D is Type Y interchangeable with V115Y. Do not replace V111 (G, H, L, Without light SY100-82-1 M, W) to V115Y (DIN terminal), or vice versa.