Transporting and Installation . 3-1 3.1 Transporting . 3-1 3.1.1 Transporting with forklift . 3-2 3.1.2 Transporting with caster . 3-3 3.2 Installation . 3-3 3.2.1 Installation conditions . 3-4 3.2.2 Installation location and maintenance work area . 3-5 3.3 Procedure for Installation . 3-6 3.3.1 Installation . 3-6 3.3.2 Procedure for system securing (1) . 3-6 3.3.3 Procedure for system securing

Symbol AMD 4.6-7 Micro Mist Separator Series AMD AMD150 to AMD850 How to Order AMD 250 03 J B Body size Options J Drain guide 1/4B female thread R IN R OUT reversal 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850 11 2 Accessories(Options) Symbol Description None Bracket T Element service indicator B N.C. auto drain C N.O. auto drain D Please refer to p.4.7-7 regarding How to Order of case

service indicator Nil B 3 4 650 1 850 11 2 N.C. auto-drain C N.O. auto-drain D Refer to the table below for accessory/option combinations.

Air inlet 22 C Draft air inlet F L 16 M Model IDFS6E IDFS8E Port size J A B C D E F G H K L M 315 380 260 470 540 85 130 350 325 440 297 330 Rc 3/4 560 530 470 540 325 260 85 130 Rc 3/4 297 315 330 440 IDFS11E 605 575 325 355 540 285 110 130 315 Rc 3/4 325 485 515 Note: The diagram above is drawn base on IDFS6E dimension with scale 1:6 6 Series IDUS/IDFS Option Specification Refer to pages

Transporting and Installation . 3-1 3.1 Transporting . 3-1 3.1.1 Transporting with forklift . 3-2 3.1.2 Transporting with caster . 3-3 HRZ Series TOC-1 HRX-OM-X010 Table of Contents 3.2 Installation . 3-3 3.2.1 Installation conditions . 3-4 3.2.2 Installation location and maintenance work area . 3-5 3.3 Procedure for Installation . 3-6 3.3.1 Installation . 3-6 3.3.2 Procedure for system securing

) 03 (3, 1/8"), 04 (4), 06 (6), 07 (1/4") only Table 1 Tubing Size Symbol Metric size Inch size Tubing O.D. 3 03 4 04 6 06 8 08 10 10 12 12 19 19 25 25 1/8" 03 1/4" 07 3/8" 11 1/2" 13 3/4" 19 1" 25 Symbol Note 1) GPS GB GB GPS Fitting type Note 1) Sizes with the same symbol number and 06 and 07 are common sizes. 6 c Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN

Sensor -2kPa 0 2kPa 5kPa 10kPa Pressure range For low differential pressure PSE550 0 2kPa -0.2kPa 2kPa Rated differential pressure range of sensor Set differential pressure range of controller 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2003 SMC CORPORATION All Rights Reserved 1st printing July, 2003 D-YGA P-120 (YGA)

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com 2010 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing LY printing OZ 7150SZ Printed in Japan. D-DN

JM-025 NSNJ-015 JM-08 NSN-03 NSN-04 0.26 0.30 0.30 0.39 0.39 0.51 0.51 1.00 1.13 1.50 2.00 2.00 2.13 2.50 2.50 3.00 0.47 0.59 0.71 0.91 1.08 1.36 2.44 2.50 3.25 4.17 4.38 4.88 5.88 7.00 7.50 1.18 1.26 5/16-24UNF 3/8-24UNF 3.07 3.24 3.99 5.19 5.38 6.14 7.14 7.16 7.66 C H B d 1/4-28UNF 3/8-24UNF 5/8-18UNF 1-12UNF 1-1/4-12UNF H 0.16 0.12 0.38 0.31 0.43 B 0.44 0.55 0.94 1.22 1.61 C 0.51 0.64

DC24V 24V SY100-61-3-05 Since a type D DIN connector has a 9.4-mm pitch between DIN terminals, it is not interchangeable. DC12V 12V SY100-61-3-06 AC100V 100V SY100-61-2-01 Type D DIN connectors have the N indication at the end of rated voltage symbol. (For DIN connectors without lights, N is not indicated. Please refer to the name plate to distinguish.)

(3-position): 0.18kg Series EVS1-01/1-02 How to Order FG S EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 NPTF Passage symbol Port size (A) 4 (B) 2 Size 02 Size 01 Piping specifications Symbol Nil A01 A02 FG Without sub-plate 1 (P) 5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B)

Programming Screen . 3-2 3.4 The Run Mode Top Menu . 3-3 3.5 The Edit Menu . 3-3 3.6 The Function Block Edit Menu . 3-3 3.7 Option Screen Setup . 3-4 3.7.1 How to change the Language . 3-4 3.7.2 Real Time Clock SET . 3-4 3.7.3 SummerTime . 3-4 3.7.4 Password . 3-4 3.8 LCD Displays . 3-5 3.8.1 Image Table . 3-5 3.8.2 LCD Function . 3-5 3.9 Block Items . 3-5 3.9.1 Input Blocks . 3-5 3.9.2 Function

Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Noise resistance 200 g 240 g Weight Note 3) Port size (Rc, NPT, G) 1/8, 1/4 3/8 1/2 Note 1) The system accuracy when combined with PF2A2/3. Note 2) Output system can be selected during initial setting. Note 3) Without lead wire.

View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.

N01 6.4 2 x 3.3 1.2 13 25 3.5 8 NPT1/8 9.8 12.5 51.8 4.2 5 Series ZSE10(F)/ISE10 Dimensions ZSE10(F)/ISE10 M5 D Panel mount adapter + Front protective cover 73.4 64.6 17.8 17.5 (67) M5 x 0.8 26.1 6.5 3 10.5 Panel thickness 0.5 to 5 10.2 51.8 4.2 17.4 ZSE10(F)/ISE10 M5R D Panel mount adapter + Front protective cover 73.4 64.6 17.8 17.5 (67) 6.5 26.1 3 Panel thickness 0.5 to 5 51.8 4.2 17.4

Rc(PT) Thread F G(PF) N NPT Accessories Options Table: Accessory/Option combinations Available Not available Depending on model L D J T AM150 R AM250 AM350 AM450 Applicable models Accessories /Options C C D -J -R AM550 AM650 AM850 Port size N.C. auto drain N.O. auto drain Accessories 06 3/4B 01 02 03 1/8B Drain guide 1/4B 10 14 20 1/4B 1B 11/2 B Options INOUT reversal 3/8B Element service

Doc. no.IZ*-OMX0012-B PRODUCT NAME Ionizer Gun MODEL / Series / Product Number IZG10 1 Doc. no.IZ*-OMX0012-B Contents Safety Instructions . 3 1. How to Order . 9 1-1. Ionizer . 9 1-2. Accessories . 9 1-3. Repair parts . 10 2. How to Use . 11 2-1. Procedures to operation . 11 3. Wiring . 12 3-1. AC adapter type/ IZG10-01, 02 . 12 3-2. Power supply cable type/ IZG10-03 . 12 4.

Thread Rc(PT) Table: Accessory/Option combinations Depends on model l Not available Available F G(PF) N NPT Accessories Options C C D -J -R D J T AMH150 R AMH250 AMH350 AMH450 Applicable models Port size Accessories Options AMH550 AMH650 AMH850 B 01 B 06 10 14 1 8 3 4 1B N.C. auto drain N.O. auto drain Drain guide 1/4B IN/OUT reversal -T Element service indicator Accessories 02 03 1 4 3

Model AMG150 AMG250 AMG350 AMG450 AMG550 AMG650 AMG850 Model Note) Rated flow (l /min (ANR)) 300 750 1500 2200 3500 6000 12000 Port size (Nominal size B) , , , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 , , 1 4 3 8 40 40 50 50 55 55 65 85 , AMH250 1 2 3 8 1 2 , AMH350 3 4 1 2 3 4 , AMH450 1 1 1 1 AMH550 AMH650 3 4 1 2 , , 14-20-34 6 Micro Mist Separator with Prefilter Series AMH AMH850 Dimensions Accessory D: With auto-drain (N.O.) for AMD850 female thread Option T: With element service indicator Courtesy of Steven Engineering