Light load Output type Stroke N NPN Stroke adjusting unit P PNP Nil Motor placement M Motor side E End side T On the top D On the bottom W Double-side Note) Refer to the catalog for Stroke, Auto switch and Number of auto switches.
MSQ Angle adjustment Range Figure 5 MSZ MSZ CRQ2X MSQX ad a ge ju Cl lt MRQ an st bo oc t r m nd en g k en tm wi in e us 10 10 se t r st on dj a ju an r on ti ot ad iti ta os ge at p ro er y nt io e b C e b n y is e ge n ad w d k an c ju lo t r C st in en g m bo st lt ju b ad M 0 ax 19 im e u ng m ra ro n ta tio Center position adjustment Table 2 R: Clockwise adjustment L: Counterclockwise
VQZ L plug connector (L): VQZ22(R)-L-C4/C6/M5 DIN terminal (Y): VQZ22(R)-Y-C4/C6/M5 VZ VS Indicator light 84 300 VFN (Lead wire length) 30.5 <35.5> 87 Max. 10 Applicable cable O.D. 3.5 to 7 Pg.7 Cover diameter 1.5 Cross section 0.23 mm2 Indicator light < >: AC 61.5 M plug connector (M): VQZ22(R)-M-C4/C6/M5 54 36 (Lead wire length) Cover diameter 1.5 Cross section 0.23 mm2 300 89 78 Indicator
M a i n c i r c u i t OUT2 24 VDC FUNC* 24 VDC Gray * Gray * FUNC* Blue * B l u e Blue + + Supply valve Supply valve Supply + valve White + Release valve Release valve White Releas e valve W h i t e Connector cord assembly Connector cord assembly Connector cord assembly (ZQ1-LW6-P-A) Connector cord assembly (ZQ1-LW6-N-A) *FUNC terminal is for energy saving operation of the supply valve
C0.5 file chamfer R sphere TP R sphere H W1 T H H Symbol: A12 Symbol: A13 Symbol: A14 Symbol: A15 Symbol: A16 Symbol: A17 Symbol: A18 Symbol: A19 MM 30 MM 30 MM 30 H A H A H A MM 30 30 L RD C B A H A L K H W MM DA 30 MM DA 30 MM MM AL H LB K A AL H AL L K H L A H Symbol: A28 Symbol: A29 Symbol: A30 30 DA 30 30 MM L W MM W A L H AL A H A T T MM H 65 Series CA2 Made to Order Specifications
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Connector Type: S (M12 connector type)
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Applicable model Minimum operating flow rate [L/min] (50/60 Hz) HRS-BP007 HRS100-28/42 HRS150-q To circulating fluid return port y To circulating fluid outlet r t w u r t r e r Parts List No.