, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, TIE ROD, VALVE, NEW SY5000 MFLD, 21, NEW SY5000 MFLD,NO SIZE RATING
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to 10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, VALVE, SOFT START, VALVE, AV SOFT START UP BODY PORT, GA, AV BODY PORT 3/8 NPT, 1.23458 lb
The seven sizes are 10, 20, 30, 50, 70, 100, and 200 with rotational adjustments from 0-190 degrees, and auto switch capability. Additional features include a hollow shaft and direct load mounting possibility.
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient fluid temperature: -10 to 50C, BLANK PLATE ASSY, VQZ2000, VALVE,
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BASE MOUNT (DC
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, SGL SOL, BASE MT (DC), VALVE, SY7000 SOL/VALVE, RUBBER SEAL, 2D, SY7000 NO SIZE RATING, 0.2474 lb
The seven sizes are 10, 20, 30, 50, 70, 100, and 200 with rotational adjustments from 0-190 degrees, and auto switch capability. Additional features include a hollow shaft and direct load mounting possibility.
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, DBL SOL, BASE MT, DIN, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, 2G, SY7000 NO SIZE RATING, 0.4114 lb
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, DBL SOL, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, EF, SY7000 BODY PT 1/4 NPT, 0.68992 lb
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, DBL SOL, BASE MT, DIN, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, 2E, SY7000 NO SIZE RATING, .40717 lb
The seven sizes are 10, 20, 30, 50, 70, 100, and 200 with rotational adjustments from 0-190 degrees, and auto switch capability. Additional features include a hollow shaft and direct load mounting possibility.
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, SUBPLATE, VALVE, VQZ200 VALVE
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL PLUG-IN BASE MNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2F, VFS4000, 1.75355 lb
Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, SGL SOL, BODY PT, DIN, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, FD, SY7000 BODY PT 1/4, .32110 lb
The seven sizes are 10, 20, 30, 50, 70, 100, and 200 with rotational adjustments from 0-190 degrees, and auto switch capability. Additional features include a hollow shaft and direct load mounting possibility.