SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20CF-T-P-N02L-W"

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 90 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen Display High-Precision Digital, VACUUM SWITCH, ZSE30, ZSE30A, N63, 93.00000 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 93.00000 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 90.00000 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 86.00000 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, VACUUM SWITCH, ZSE30, ZSE30A, N63, 90 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. VACUUM SWITCH, ZSE30, ZSE30A. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 93.00000 lb. N63.

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. VACUUM SWITCH, ZSE30, ZSE30A. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 87.00000 lb. N63.

With air cushion 15 LH B 4 x LD Z Y X W LZ LX 2 x LC (Knock pin position) ZZ + S Stroke LS + Stroke Y X W M (mm) B 54.5 78 LS 54 LX 71 LZ 4 M 10 W 4 LC 7 LD 30 LH 3 LT 16.5 X 8.5 Y Z 63.5 205 ZZ Bore size 40 50 63 5 5 10 12 40 45 91 91 4.5 4.5 17.5 17.5 70.5 75.5 66 82 86 106 5 5 22 22 11 13 242 242 82.5 75.5 Other dimensions are the same as basic type.

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)0.6 to 5 V ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)1 to 5 V ?2.5% F.S.?

This is a legacy product, and replaced byISE20C-Y-P-N02-W-X500 ISE40/50/60 PRESSURE SWITCH. SWITCH ASSEMBLY. INSTRUMENTATION. ISE40/50/60 1/4 NPT VERSION. .34295 lb. DB.

Height: 30 mm (LOW type), 100 mm (HIGH type) W H L2 T L1 [mm] Model C(L)KQG32 Compact cylinder type (Guide pin diameter: 12) C(L)KU32 Plate cylinder type (Guide pin diameter: 12) C(L)KQG50 (Guide pin diameter: 13) Clamping height LOW type HIGH type LOW type HIGH type LOW type HIGH type Clamping height H 30 100 30 100 24 54 Body thickness T 50 29 66 Body width W 50 70 66 Body length L1 127

condition r C = 0.90 based on condition r 2 2 Based on condition t, A and C Corrected air flow = 350 (0.75 x 1.00) = 467 l/min (ANR) 3 3 Based on condition t, B and C Corrected air flow = 1200 (0.95 x 0.90) = 1400 l/min (ANR) Based on condition y; IDUS4E is selected as the model to process an air flow larger than 467 l/min (ANR) with a 50Hz power supply, according to data D-1.

Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -

Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specifications: Unit Selection Function, Initial value psi, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

R/W undetected: NFC reader/writer driver is installed. NFC reader/ writer is not identified or USB is not connected. R/W detection/ R/W no-detection button 5 R/W detected: NFC communication with the wireless unit is available. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U is used. No driver: NFC reader/writer is not identified or USB is not connected.

R/W undetected: NFC reader/writer driver is installed. NFC reader/ writer is not identified or USB is not connected. R/W detection/ R/W no-detection button 5 R/W detected: NFC communication with the wireless unit is available. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U is used. No driver: NFC reader/writer is not identified or USB is not connected.

R/W undetected: NFC reader/writer driver is installed. NFC reader/ writer is not identified or USB is not connected. 5 R/W connection status R/W detected: NFC communication with the wireless unit is available. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U is used. No driver: NFC reader/writer is not identified or USB is not connected.

3 w e q !1 r y o e t !2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 Built-in magnet Without magnet Single acting u i r y o e w i e u !