SMC Corporation of America
Elite Part Number Search
Search Results "GA46-2-01"

Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 01 (1/8), Option: Standard, Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: RZ (R + Z)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: Standard, Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 1 (Meter-in), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 01 (Ø1/8), Seal Method: None

Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 0 (Meter-out), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 01 (Ø1/8), Seal Method: None

Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 0 (Meter-out), Thread Type: R, Port Size: U10/32 (10-32 UNF), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 01 (Ø1/8), Seal Method: None

Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 1 (Meter-in), Thread Type: R, Port Size: U10/32 (10-32 UNF), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 01 (Ø1/8), Seal Method: None

Differential Pressure Gauge GD40-2-01 is ideal for maintenance and management of filters, etc.Features· The pressure differential between the inlet and outlet of compressed air equipment can be seen at a glance.· Can be installed easily by providing a bypass circuit.· Includes a protective cover to prevent danger.

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Mounting: B (Bracket), Semi-Standard, Body Size 10: 2 (Metal Bowl), Semi-Standard, Body Size 20: Z (Name Plate, Caution Plate for Bowl in Imperial Units: psi, °F), Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 01 (1/8), Mounting: None, Semi-Standard, Body Size 10: 2 (Metal Bowl), Semi-Standard, Body Size 20: R (Flow Direction: Right to Left), Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Mounting: None, Semi-Standard, Body Size 10: 2 (Metal Bowl), Semi-Standard, Body Size 20: Z (Name Plate, Caution Plate for Bowl in Imperial Units: psi, °F), Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: H (Set Nut for Panel Mount), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: Standard, Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X406 (0.4 MPa Setting)

Body Size: 20, Thread: F (G), Port Size: 01 (1/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 1CN (1 + C + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 1C (1 + C), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: CN (C + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Semi-Standard 1: N (Non-Relieving Exhaust Mechanism), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)