SMC Corporation of America
Elite Part Number Search
Search Results "G46-10-01-C"

Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 2 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: T (NPTF), Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: Q (CE Marked)

Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: T (NPTF), Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: Q (CE Marked)

Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 6 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 01 (1/8), Thread: Rc, Control Unit: A (Air Filter w/Auto Drain, Regulator, Air Release Valve), Voltage of Air Release Valve: 5 (24VDC)

.· Y24-□01-A, 02-A applicable model: AC20□-A.· Y34-□01-A, 02-A applicable models: AC25□-A, AC30□-A.· Y44-□02-A, 03-A applicable model: AC40□-A.· Y54-□03-A, 04-A applicable model: AC40□-06-A.

Metric size Inch size 3.2 01 03 05 07 09 11 23 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Control type 4 6 8 10 0 1 Meter-out Meter-in Use 1/8" tube.

Note1) Metric size Inch size Note 3) 23 3.2 Note 2) 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Stainless steel type (Stainless steel 303) 04 4 06 6 08 8 10 10 12 12 16 16 Note 1) The material can be visually identified by color of the release button. Stainless steel type: White Note 2) White is also used for inch size.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, .83984 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71092%8%0.2 to 7.0 l/min0.2 to 7.4 l/min0 to 7.4 l/min3.80 V15.2 mA

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FR/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, CA, AC MASS PRO 1/8 MODULAR (PT), 0.88184 lb

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide.

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide.

Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., Low Profile Dig Pres Switch, PRESSURE SWITCH, 829, 23 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, .72150 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM72592%8%0.5 to 25.0 l/min0.5 to 26.3 l/min0 to 26.3 l/min5.00 V20.0 mA

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/R/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, CA, AC MASS PRO 1/8 MODULAR (PT), 2.20462 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/MS/R COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, CA, AC MASS PRO 1/8 MODULAR (PT), 2.20462 lb, ModelComponentPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 2)Proof pressureMaximum operating pressureMinimum operating pressureSet pressure rangeRelief pressureNominal

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FR/MS COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, CA, AC MASS PRO 1/8 MODULAR (PT), 2.30482 lb, ModelComponentPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 2)Proof pressureMaximum operating pressureMinimum operating pressureSet pressure rangeRelief pressureNominal

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/R COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, CA, AC MASS PRO 1/8 MODULAR (PT), 1.98416 lb, ModelComponentPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 2)Proof pressureMaximum operating pressureSet pressure rangeRelief pressureNominal filtration ratingBowl materialBowl

This series is available in four body sizes with piping from M5 to 3/4 in Rc, NPT or G thread types.Modular type filter regulator , Rated filtration ( m): 2, 10, 20, 40 , 70 or 100 , Optional embedded pressure gauge , Available with built-in backflow mechanism , Rc, G(PF) or NPT threads, FILTER/REGULATOR, FILTER/REGULATOR, MODULAR F.R.L., M98, 0.20000 lb