AS-FM Series Speed Controller for Low Speed Operation with One-touch Fitting Elbow Type/Universal Type (Resin Body) How to Order AS 2 2 0 1 F M 01 06 Lock nut option Nil J Hexagon lock nut Round lock nut AS-F Body size TMH 1 2 M5 standard 1/8, 1/4 standard Made to Order Refer to the below for details.
ASN AQ ASV AK How to Order VCHC F S 1 0 03 06 3 2 AS ASR ASQ Hexagon lock nut Round lock nut J Nil Lock nut option Speed controller Option None Electroless nickel plated Nil N Body size 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size Note) With seal 4 6 8 10 12 04 06 08 10 12 Made to Order Refertopage612for details.
Body size Metric size 06 08 10 12 Inch size 07 09 11 13 3 4 5 6 1/8 1/4 3/8 1/2 6mm 8mm 10mm 12mm 1/4 5/16 3/8 1/2 Thread size Universal type 1/8 1/4 3/8 1/2 01 02 03 04 With One-touch fitting Uni-fit thread form Dimensions Models TUBE O.D. d L3 Applicable tubing O.D.
Body O.D.:98 06 Rc3/4 10 Rc1 Model Port size Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1 XTO-2571 XTO-1239 XTO-1719
(mm) Note) Type 04 06 08 10 12 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Made to Order (For details, refer to page 659.) Control type Note) For applicable tubing O.D. selection, refer to the Model.
1/2 standard Applicable tubing O.D. 06 08 10 12 6 mm Type 8 mm 3 Universal 10 mm 12 mm With One-touch fitting Port size 02 03 04 R1/4 R3/8 R1/2 Flow valve: Series ASQ Model Model Applicable tubing O.D.
(UL standard V-0) Applicable model: ASV310F, ASV410F, ASV510F Inch size Note) Elbow: M3, M5 only Port size AS 04 06 08 10 12 03 07 09 11 13 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" M3 M5 U10/32 01 02 03 04 M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 With One-touch fitting Thread type ASP Brass parts are all electroless nickel plated.
AS1F-D Series Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting Elbow Type/Universal Type How to Order AS 2 2 1 1 F 01 06 S D Body size Type adjustable by flat head screwdriver AS-F 1 2 3 4 M5 standard With seal 1/8, 1/4 standard 3/8 standard 1/2 standard Note) In the case that port size is either M5 or 10-32 UNF thread, it is not available with seal.
Free flow Controlled flow Weight (kg) Model Port size Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Critical pressure ratio Critical pressure ratio Sonic conductance dm3/(sbar) Sonic conductance dm3/(sbar) 1/4 3/8 1/2 3/4 1 1 1 10 3,600 4,800 6,700 8,100 16,900 38,500 47,500 60,800 AS420-02 AS420-03 AS420-04 AS500-06 AS600-10 AS800-12 AS900-14 AS900-20 2,500 5,000 6,600 6.9 13.9 18.3 28.1
Note) Metric size 23 04 06 08 10 12 Inch size 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 Made to Order (For details, refer to page 622.)
Symbol How to Order 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D. (mm) 04 06 08 10 12 Type 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Control type Meter-out Meter-in 0 1 With residual pressure release valve With One-touch fitting 15-9-36
side Valve side applicable tubing O.D.*1 06 6 08 8 10 10 With One-touch fittings *1 For selecting applicable tubing O.D., refer to the cover page. 1
Liquid contact body material Automatically operated type Port size 1 2 ADC12 (Aluminium) SCS14 (Stainless steel) 03 04 06 3/8 (10A): PA3 1/2 (15A): PA5 3/4 (20A): PA5 Diaphragm material Thread type 1 2 PTFE NBR T F N Rc NPTF G NPT Automatically operated type Air operated type (external switching type) 1 1 PA 3 03 3 55 Symbol FLUID OUT P1 P2 Body size Port size ATEX Category 2 03 04 06 3
Vertical Suction Filter FHIA Series How to Order FH I A N 04 M M R 074 Vertical suction filter Relief valve Hydraulic fluid R D N W V With relief valve None (Blanking plate) Petroleum Water-glycol, Emulsion Phosphoric ester Differential pressure indication Differential pressure indicator Differential pressure indication switch Note) Port size M E D 04 06 08 10 12 16 20 24 28 32 1/2B None
Ionizer IZN10 Series RoHS How to Order 01 P IZN10 06 High frequency AC nozzle type Without maintenance detector X194 Made to Order Nozzle type Type Energy saving static neutralization nozzle Symbol Refer to page 449. 01 High flow rate nozzle 02 Bracket Female threads for piping Note) Rc1/8 11 Without bracket Nil Note) Nozzle shape: When using the female thread for the piping, connect the
Nozzle Type Ionizer IZN10E Series How to Order Energy saving static neutralization nozzle 01 P IZN10E 06 Z B1 High flow rate nozzle Female threads for piping High frequency AC nozzle type Bracket Nozzle type Symbol Type Part no.
Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 Applicable tubing O.D. mm 3.2 4 6 8 10 12 16 Applicable hose I.D.
Open type, Dripproof/Rainproof, Splashproof /Low jetproof type 1 0 NBR FPM Metal material for wetted parts Enclosure 0 Open type 1 0 Brass, Phosphor bronze Dripproof/Rainproof type (Equivalent to IP42) 1 Stainless steel 304 Splashproof/Low jetproof type (Equivalent to IP44) 2 Port size 10 06 3/4 1 Thread type ON-flow range Note 1) IF30 is available for 06.
Valve for Water and Chemical Base Fluids VCC Series How to Order Manifold 02 VV CC1 G M 06 C4 04 With gate valve Passage number Gate valve and cleaning valve mountable number 2 port valve, Cleaning valve 2/3 port valves mixed mounting 2 M 02 04 06 Cleaning valve (2 port valve): 1 pc. + Gate valve: 1 pc. Cleaning valve (2 port valve): 3 pcs. + Gate valve: 1 pc.
How to Order VCHN 06 3 Option Port size Nil None Symbol VCHN4 VCHN3 Port size F With freeze reduction 06 10 12 14 R3/4 Symbol R1 Body size R11/4 3 4 R11/2 608