SY5, Actuation: 2 (2 Position Double), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,B Port Size: N7

(2 Position Double), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: B [Quick Response Type (0.7MPa)], Coil Specification: Standard, Voltage: 6 (12VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,B Port Size: N7

Actuation: 3 (3 Position Closed Center), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,B Port Size: N7

/N.C.), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,B Port Size: N7 (ø1/4" One-touch Fitting),

/N.O.), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,B Port Size: N7 (ø1/4" One-touch Fitting),

Actuation: 4 (3 Position Exhaust Center), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: Without light/surge voltage suppressor, Non-polar, Manual Override: Non-locking Push Type, A,B Port Size: N7

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: B (Out 1: PNP; Out 2: PNP)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: B (Out 1: PNP; Out 2: PNP)