input 45 F22 Analogue Output Setting 46 F30 Accumulated Value Hold 47 F32 Flow direction setting 48 F33 Close proximity setting 50 F34 Zero-reset setting 51 F80 Setting of Power Saving Mode 52 F81 Setting of Security Code 53 F82 Input of Line Names 54 F90 Settings of All Functions 55 F98 Check of Output 56 F99 Reset to the Default Setting 57 Other Settings 58 Maintenance and Inspection 60

If the specific gravity of the slurry is less than 3, use particles that have a diameter of no more than 0.25 mm and have been passed through a #60 or finer mesh (e.g. aluminum powder).

If the specific gravity of the slurry is less than 3, use particles that have a diameter of no more than 0.25 mm and have been passed through a #60 or finer mesh (e.g. aluminum powder).

A: Reference life (time) Reference life (day) = Operating frequency of the solenoid valve (Hz) x operating time per day (hour) x 60 (min.) x 60 (sec.)

A: Reference life (time) Reference life (day) = Operating frequency of the solenoid valve (Hz) x operating time per day (hour) x 60 (min.) x 60 (sec.) Model How to operate Reference life (time) A The discharge for one cycle. PB1313A Air operated type 50 million times Approx. 3mlNote1) Note1) This is not a metering pump. The amount of discharge depends on the operating condition. 9 4.

Ratio of discharge amount to fresh water () 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPas) mPas Recommended typical condition B: Calculate discharge amount of fluid with viscosity 100mPas in case of discharge rate 4.5L/min and discharge pressure 0.1MPa. 1. Find ratio of discharge rate to fresh water for the fluid with viscosity 100mPas from the graph.

Specifications Valve construction Metal seal Fluid Air Max. operating pressure 1.0MPa External pilot air pressure 0.2 to 1.0MPa (External pilot type) Frequency adjustment range 1 to 5Hz (internal pilot type) 1 to 8Hz (external pilot type) Proof pressure 1.5MPa Ambient and fluid temperature -20 to +60 oC Lubrication No Enclosure rating IP65 equivalent Weight About 1,400g Use an External pilot

Keep the temperature of the switch below 60 oC. Selection All models 1. When controlling valve responsiveness, take note of the size and length of piping, as well as the flow rate characteristics of the actuating solenoid valve. 2. Keep the pilot pressure within the specified range. 3. Keep within the specified range of the pilot pressure. 0.4 MPa to 0.5 MPa is recommended.

The switch section should be kept at the temperature no greater than 60 oC. Selection Caution All models 1. When controlling valve responsiveness, take note of the size and length of piping, as well as the flow rate characteristics of the actuating solenoid valve. 2.

The switch section should be kept at the temperature no greater than 60 oC Selection All models 1. When controlling valve responsiveness, take note of the size and length of piping, as well as the flow rate characteristics of the actuating solenoid valve. 2. Actuating pressure should be kept within the specified range. 0.4 MPa to 0.5 MPa is recommended. 3.

The fluid and ambient temperatures should be -10 to 60 C. Operation under low temperature leads to cause damage or operation failure due to frozen moist in the fluid or air. Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water. Avoid sudden temperature change even within specified temperature.

ON 3. 60 ON 4. OFF ( OFF 1. 2. ON 24 4. (XC85,X446) 4-1. -XC85 GR-H-010(10g) <> splash zone <> splash zone 4-2.

D-M9V-900 1 D-M9WV-900 55 30 (n 4 65 30 (n 4 60 30 (n 4 70 30 (n 4 10 30 (n n=(4,8,12,16) n n=(4,8,12,16) n=(4,8,12,16) n=(4,8,12,16) n=(2,4,6,8) 15 Auto switch Connection and Example 16 3.

60 MXQ20(A,C) 30.2 19.2 19.2 19.2 19.2 19.2 19.2 19.2 19.2 34.9 35.9 35.9 35.9 41.9 50.9 75.9 75.9 75.9 MXQ25(A,C) 32.4 23.4 23.4 23.4 23.4 23.4 23.4 23.4 23.4 42.7 41.7 41.7 41.7 54.7 54.7 40.7 79.7 77.7 A 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXQ6B 16 5.4 5.4 5.4 5.4 5.4 15 25.6 25.6 31.6 48.6 25.6 MXQ8B 27 11.9 11.9 11.9 11.9 11.9 11.9 16 23.1 23.1 31.1 31.1 50.1

Operable temperature range is -10 to 60 deg.C (No freezing). Use the product within this range. If the cylinder is used outside of the operable temperature range, the seal can be worn out due to hardening of the seal and lubrication failure of the grease, causing air leakage.

This compact cylinder is applicable within the range from 10 to 60 C. Make sure to keep it during operation. In case of immoderate use over the range, extreme wearing due to hardening of packing may result in air leak and lubrication failure as lubrication grease cannot perform fully. 11.

a0~60 b25~85%RH c d e 5. f g. h i 6. j k L 2. 7. 8. 1. 9. 2. 10. 11. ()70% ()35% 1. 15% 1. 2. 3 3. () 1. 0.1~1.0MPa 0.3~0.5MPa 0~60 ()35% 2. ) 1. 1. 2. 2. 3. 1. 1. ( 2. 6 ) 3. 2. 50% 4. (6 ) 3. 5. 4. () 0.5 5. 1 2 3. F.G. 1. 4. 1 ISO VG32 1. 2. 1. 2. 3. 1. 2 1. 2. 2. 14.5mT CE2 1.5~2 15,000 18cm 3. 4. IP65 5.

Place where ambient temperature exceeds the range of 0 to 60. b. Place where ambient humidity exceeds the range of 25% to 85% RH. c. Place where condensation occurs due to sudden temperature change. 4. Deceleration circuits or shock absorbers are d. Place where atmosphere containing corrosive gas, flammable gas or organic solvent. needed in some cases.