Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to +60°C, VALVE DBL PLUG-IN BASE MOUNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2I, VFS4000, 1.7196 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SGL PLUG-IN BASE MOUNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, QD, VFS4000 BASE MT 3/8, .00000 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SGL NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2D, VFS4000, 1.38891 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2Q, VFS4000, 3.60087 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SOL 24VDC, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2I, VFS4000, 3.92671 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL PLUG-IN BASE MNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, RG, VFS4000 BASE MT 1/2, 2.866 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, PLUG-IN SUBPLATE, VALVE, VFS4000 SOL VALVE 4/5 PORT, R1, VFS4000 BASE MT 1/2, 2.00437 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SOL/PILOT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2E, VFS4000, 1.73808 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SOL/PILOT 24VDC, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2E, VFS4000, 1.78861 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL PLUG-IN BASE MNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, RF, VFS4000 BASE MT 1/2, 2.866 lb
(n 2)/2 20 + 55 (n 2)/2 60 + 55 (n 4)/2 60 + 55 (n 4)/2 80 + 55 (n 4)/2 105 + 55 (n 4)/2 110 + 55 (n 4)/2 115 + 55 (n 4)/2 n A6 n = 2, 4, 6, 8 n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 15 20 60 70 85 110 115 120 2 20 + 55 (n 2)/2 25 + 55 (n 2)/2 65 + 55 (n 4)/2 70 + 55 (n 4)/2 85 + 55 (n 4)/2 110 + 55
[What is the ATEX Directive?]Compliance with the ATEX Directive is required for equipment used in potentially explosive atmospheres within the EU from July 1, 2003.· CE Mark and ATEXThe ATEX Directive is part of the CE Mark scheme and incorporates existing European explosion-proof standards.· Goals of the ATEX DirectiveThe principal goals of ATEX are as follows.· Prevention of static charge
[What is the ATEX Directive?]Compliance with the ATEX Directive is required for equipment used in potentially explosive atmospheres within the EU from July 1, 2003.· CE Mark and ATEXThe ATEX Directive is part of the CE Mark scheme and incorporates existing European explosion-proof standards.· Goals of the ATEX DirectiveThe principal goals of ATEX are as follows.· Prevention of static charge
CYL, PIN CLAMP, KOREA SPL, ACTUATOR, CKQ/CLKQ PIN CLAMP CYLINDER, PE, 63MM CKQ, CLKQ DBL ACT, SW CAP
CYL, PIN CLAMP, KOREA SPL, ACTUATOR, CKQ/CLKQ PIN CLAMP CYLINDER, PE, 63MM CKQ, CLKQ DBL ACT, SW CAP
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, ISO, AUTO-SW, ACTUATOR, C95/C96 TIE-ROD CYLINDER, V7, 160MM C95/CP95, 2.37153 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, ISO, AUTO-SW, ACTUATOR, C95/C96 TIE-ROD CYLINDER, V7, 160MM C95/CP95, 8.50895 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, NON LUBE,AUTO-SW, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, PE, 63MM CA1 DBL-ACT AUTO-SW, 10.29866 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR, DBL ACT, AUTO-SW, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, LE, 32MM CG DBL-ACT AUTO-SW, 1.23458 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RND BODY, DIR MT, DBL/ACT, ACTUATOR, CJ2 ROUND BODY CYLINDER, GE, 16MM CJ2 DBL-ACT AUTO-SW, 7.05479 lb