Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 1 (Meter-in), Indicator Direction: 1 (180°), Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9mm, Tubing: 03 (ø5/32")
Function: 1 (2 Position Single), Body Option: 1, Piping: 0 (Side), Port Size: 03 (3/8), Voltage: 5 (24VDC), Electrical Entry: U (Grommet), Option: None, Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 1, Piping: 0 (Side), Port Size: 03 (3/8), Voltage: 5 (24VDC), Electrical Entry: C (Conduit), Option: None, Thread: N (NPT)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: Standard, Attachment: Standard, Semi-Standard 1: 16 (1 + 6), Semi-Standard 2: RWZ (R + W + Z)
Body Size: 30, Thread: Rc, Port Size: 03 (3/8), Option: Standard, Attachment: SV (S + V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port Size: 03 (3/8), Option: Standard, Attachment: SV (S + V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V)
Set Flow: 10 (1~10l/min), Thread: N (NPT), Port Size: 03 (3/8), Terminal Box: 1 [Terminal Box (Contact 1ab)], Neon Lamp: 0 (w/o Neon Lamp)
Set Flow: 10 (1~10l/min), Thread: Rc(PT), Port Size: 03 (3/8), Terminal Box: 1 [Terminal Box (Contact 1ab)], Neon Lamp: 0 (w/o Neon Lamp)
Piping: 1 (Bottom Direction), Body Color: BU (Dark Blue), Piping Type: Rc, Connection Size: 02 [Screw-in (Port Size 1/4)], Nozzle: 03 (Male Thread, KN-R02-200)
Piping: 1 (Bottom Direction), Body Color: W (Urban White), Piping Type: Rc, Connection Size: 02 [Screw-in (Port Size 1/4)], Nozzle: 03 (Male Thread, KN-R02-200)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: DE (D + E), Attachment: Standard, Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: RZ (R + Z)
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Standard
Body Size: 30A, Thread: N (NPT), Port Size: 03 (3/8), Option: Standard, Attachment: Standard, Semi-Standard 1: 13 ( 1 + 3), Semi-Standard 2: NRZ (N + R + Z)
Size: 30 (3/8), Thread: M Thread, Rc(PT), Port Size: 03 (3/8), Accessory: None, Option 1: 1 (1000cm³ Tank), Option 2: R (Flow Direction: Right->Left)
Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 2 μm, Element Seal Material: T (Fluororesin), Accessory: B (Bracket), Made to Order: X77 (Differential Pressure Indicator)
Body Class: 2 (Orifice Diameter ø4), Valve Type: 0 (Normally Closed), Applicable Tube OD: 03 (Rcø3, NPT1/8), Port B OUT: Ports A & B Same Size, Pilot Port: Body Class 2 - M5 Thread; Body Class 3, 4, 5, 6 - Rc1/8, Material: Body PFA, Actuator Endplate PPS, Diaphragm PTFE, Option: None, Specification: V (Vacuum)
Series: 542 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Electrical Entry: H (Grommet, 600mm Lead Wire Length), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Model: 33, Orifice: 3 (3mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)