Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.600, Format: With internal shock absorber, Size: 100, Switch: M9B
Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating Pressure Range(MPa): 0.1~0.7, Size: 3, Connection port location: End face port, Switch: M9B
Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006, Operating Pressure Range(MPa): 0.1~0.7, Size: 7, Connection port location: End face port, Switch: M9B
Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 8, Valves: Not Provided, Allowable Kinetic Energy(J): 0.0015, Operating Pressure Range(MPa): 0.1~0.7, Size: 2, Connection port location: End face port, Switch: M9B
Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating Pressure Range(MPa): 0.1~0.7, Size: 3, Connection port location: End face port, Switch: M9B
Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating Pressure Range(MPa): 0.1~0.7, Size: 3, Connection port location: Front ported, Switch: M9B
Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006, Operating Pressure Range(MPa): 0.1~0.7, Size: 7, Connection port location: End face port, Switch: M9B
Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006, Operating Pressure Range(MPa): 0.1~0.7, Size: 7, Connection port location: Front ported, Switch: M9B
Sensor Type: Non-Contact, Output Format: NPN Format, Wiring Method: 3-Wire, Type: Main Body, Wiring type: 2-wire, Output Type: None, Electrical entry direction: In-line, Lead wire length(m): 0.5, Connector Type: None
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: