SMC Corporation of America
Elite Part Number Search
Search Results "CXSM20-80-Y7PMAPCS"

(Example) Step data "force" is 100% Step data "Trigger LV" is 80% The energy saving setting of the electric actuator is 40% force (%) INP (ON) The actuator model determines the energy settings.

Pushing force INP output [ON] (%) 100 80 Tligger LV Energy saving mode 40 Time When the actuator is within the output range between Area1 and Area2 in the step data, this terminal will turned ON.

Please refer to the manual of the actuator for more details. 0 Pushing force INP (ON) (%) 100 Trigger LV 80 Energy saving mode 40 Time When the actuator is within the output range between Area1 and Area2 in the step data, this signal will turn ON.

(Example) Step data force is 100% B10 INP INP (ON) force 100 80 Step data Trigger LV is 80%, The energy saving setting of the electric actuator is 40% 40 The electric actuator model determines the energy settings.Please refer to the specifications of the electric actuator for more details.

Pushing force 1 0 to 30 10% RWwn+6 Trigger LV 1 0 to 30 10% Pushing speed 1 0 to 255 mm/s RWwn+7 Positioning thrust 1 0 to 30 10% H RWwn+8 L In pos 2 0 to 65500 0.01mm ID2 RW+9 to 17 Same as ID1 ID3 RWrn+18 to 26 Same as ID1 ID4 RWrn+27 to 35 Same as ID1 ID5 RWrn+36 to 44 Same as ID1 ID6 RWrn+45 to 53 Same as ID1 ID7 RWrn+54 to 62 Same as ID1 ID8 RWrn+63 to 71 Same as ID1 ID9 RWrn+72 to 80

+/-2147483647 0.01mm 4 1 5 0 6 H Current speed 2 0 to 65500 mm/s 7 L 8 H Current Force 2 0 to 300 % 9 L Numerical data 10 3 input ID1 Target 11 2 position 4 +/-2147483647 0.01mm 12 1 13 0 14 Alarm 0 to 255 15 Alarm 0 to 255 4 16 Alarm 0 to 255 17 Alarm 0 to 255 18 19 Controller IF status flag (ID=1) All modes ID2 20 to 39 Same as ID1 ID3 40 to 59 Same as ID1 ID4 60 to 79 Same as ID1 ID5 80

ID 14 Alarm 0 to 255 15 Alarm 0 to 255 Numerical data 4 input 16 Alarm 0 to 255 ID1 17 Alarm 0 to 255 18 19 Controller IF status flag(ID=1) All modes ID2 20 to 39 Same as ID1 ID3 40 to 59 Same as ID1 ID4 60 to 79 Same as ID1 ID5 80 to 99 Same as ID1 ID6 100 to 119 Same as ID1 ID7 120 to 139 Same as ID1 ID8 140 to 159 Same as ID1 ID9 160 to 179 Same as ID1 ID10 180 to 199 Same as ID1 ID11

67 125 304 33 73 31 36 154 21 330 231 15 IDFA4E to 11E B A D E Q SWITCH WITH LAMP AIR INLET THERMOMETER EVAPORATION AIR OUTLET G F C DRAFT AIR OUTLET VENTILATION VENTILATION (O.D.10 LENGTH:0.8m) DRAIN TUBE TERMINAL BLOCK (820) J K L H 4-13 P M N POWER SUPPLY ENTRY(17) GROMMET Measuremm Model Thread Size A B C D E F G H J K L M N P Q IDFA4E Rc1/2 453 13 498 283 275 IDFA6E 455 Rc3/4 270 80

Using this product at high temperatures (40 to 80 oC) may cause burns. Do not touch the surface until it is cooled down to less than 40oC. Connect IN and OUT correctly. (Make sure that reverse flow will not be generated) Make sure that back flow will not be generated. The element might break due to exposure to back flow.

VXF21A VXF22A VXF23A VXF24A VXF27B VXF28B VXF25(A,B) VXF26(A,B, C,D) Product number Orifice size mm 22 28 44 53 70 80 90 100 Air Fluid Minimum operating pressure Maximum operating pressure MPa 0.03 0.1 MPa 0.7 Fluid temperature -10 (Non-freezing) to 60 Ambient temperature -10 to 60 Coil insulation type Class B Enclosure IP65 Alloable voltage fiuctuation 10% of rated voltage AC VA 10 7

Reference data Units: mm IDH6 Jumper cord 7 6 5 4 3 1 PE Remote start/stop Fault-signal (N.O: Close at "Fault") Fault-signal (N.C: Open at "Fault") 1042 31 N 2 L Operation-signal (N.O) Ground Terminal screw: M3 Suitable wire: 1.25mm or more 2 244 Power supply Connector width: 6.5mm or less Detail of wiring 35 184 172 392 (Note) 15 80 223 321 3001 485 The type without built-in filter does

IDG100LA IDG60SA IDG75SA IDG100SA Compressed Air Fluid Range of operating conditions Inlet air pressure MPa 0.31.0 -550 -550 Inlet air temperature oC Ambient temperature oC Standard performance Outlet air atmospheric pressure dew point oC Inlet air flow rate L/min(ANR) 224 308 400 75 140 230 Outlet air flow rate L/min(ANR) 170 240 300 50 100 150 Purge air flow rate L/min(ANR) 54 68 100 25 40 80

As a general rule, use 80 to 100 mesh. Although the product has a scraper to prevent foreign matter from entering into the product, fluid containing fine foreign matter such as abrasive powder may cause sealing failure by the foreign matter adhering to the rod sliding part.

Cross Reference Table of the Inner Sleeve (Metric size) Tubing Temperature FEP tubing/Series TH 80 or more Super PFA tubing/Series TL 120 or more Tubing O.D. Tubing material Applicable inner sleeve TUS (Soft polyurethane) TH/TIH (FEP) TL/TIL (Super PFA) Part no.

Cross Reference Table of the Inner Sleeve (Metric size) Tubing Temperature FEP tubing/Series TH 80 or more Super PFA tubing/Series TL 120 or more Tubing O.D. Tubing material Applicable inner sleeve TUS (Soft polyurethane) TH/TIH (FEP) TL/TIL (Super PFA) Part no.

Note 3) AC adapter Model IZG10-CG 100 to 240VAC, 50/60Hz Input voltage Note 1) Output voltage Output current Ambient temperature Ambient humidity 24VDC +/-5% 0.8A max 0 to 40oC 20 to 80%Rh Applicable standard/directive CE cUL Note 1) AC cord for IZG10-CG1 is only for use in Japan (Rated voltage: 125V, Plug: JIS C8303, Inlet: IEC60320-C13). 22 Doc. no.IZ*-OMX0012-B 8.

Install the product in a location where the ambient temperature range is Connect the host to this unit with a twisted pair shield cable when applying between 10 to 35C and the relative humidity range is between 35 to 80%. No dew condensation is allowed on the unit. communication function or external sensor and alarm output function.

motor (100/200VAC) Type of Motor S2,S3 Incremental 17bit encoder (Resolution:131072 p/rev) Type of Motor S6,S7 Absolute 18bit encoder (Resolution:262144 p/rev) specification Encoder Electric Type of Motor T6,T7 [With LECSB-T/LECSS-T]Absolute 22bit encoder (Resolution: 4194304 p/rev) [With LECSC-T]Absolute 18bit encoder (Resolution:262144 p/rev) Power consumption[W] Note6) Horizontal 65 80

37.3 1.5 28 42.5 75.7 42.5 1/43/81/2 1/8 AW40-06-B 75 149.1 93.2 37.3 80 37.3 1.2 28 42.5 75.7 42.5 3/4 1/8 44.3 AW60-B 95 234.1 175.5 47.5 30 47.5 3.2 28 42.5 80.8 42.5 1 1/8 Optional Bracket mount dimensions Panel mount dimensions Model Q S T U AW20-B 30 34 43.9 5.4 15.4 55 2.3 24.7 28.5 14 6 AW30-B 41 40 45.8 6.5 8 53 2.3 31.1 38.5 19 7 AW40-B 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21

Do not mount the product where it is exposed to materials such as Cooling capacity Option silicone, which may generate harmful gas. 002 200W Nil None Install the product in a location where the ambient temperature range is E With foot, 004 400W no rack bracket between 10 to 35C and the relative humidity range is between 35 to 80%.