Size: 4 [15scfm, 25m³/hr (ANR)], Voltage: 11 (Single-phase, 115VAC, 60Hz), Connection Port Thread: 10mm (Size 3 to 15, Rc; Size 22 to 75, R; 10mm Drain Tube), Option: T (Terminal Block for Run & Alarm Signal)

Size: 6 [25scfm, 43m³/hr (ANR)], Voltage: 11 (Single-phase, 115VAC, 60Hz), Connection Port Thread: 10mm (Size 3 to 15, Rc; Size 22 to 75, R; 10mm Drain Tube), Option: T (Terminal Block for Run & Alarm Signal)

Size: 8 [41scfm, 70m³/hr (ANR)], Voltage: 11 (Single-phase, 115VAC, 60Hz), Connection Port Thread: 10mm (Size 3 to 15, Rc; Size 22 to 75, R; 10mm Drain Tube), Option: T (Terminal Block for Run & Alarm Signal)

Size: 75 [300scfm, 510m³/hr (ANR)], Voltage: 46 (Three-phase, 460VAC, 60Hz), Connection Port Thread: 10mm (Size 3 to 15, Rc; Size 22 to 75, R; 10mm Drain Tube), Option: T (Terminal Block for Run & Alarm Signal)

Size: 15 [3.1m³/min (ANR), 109.5scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 11 [1.82m³/min (ANR), 64.27scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 6 [0.82m³/min (ANR), 28.96scfm], Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 8 [91m³/hr (ANR), 53.6scfm], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 6 [0.82m³/min (ANR), 28.96scfm], Version: NIL (All Sizes Except 15), Voltage: 20 [200VAC (50Hz), 200/220VAC (60Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 11 [1.7m³/min (ANR), 60.03scfm], Version: NIL (All Sizes Except 15), Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase)], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 3 [0.37m³/min (ANR), 13.07scfm], Version: NIL (All Sizes Except 15), Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase)], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 4 [0.57m³/min (ANR), 20.13scfm], Version: NIL (All Sizes Except 15), Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase)], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 6 [0.82m³/min (ANR), 28.96scfm], Version: NIL (All Sizes Except 15), Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase)], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 8 [1.2m³/min (ANR), 42.38scfm], Version: NIL (All Sizes Except 15), Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase)], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 22 [4.3m³/min (ANR), 151.9scfm], Version: NIL (All Sizes Except 15), Voltage: 23 [230VAC (50Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 22 [4.3m³/min (ANR), 151.9scfm], Version: NIL (All Sizes Except 15), Voltage: 30 (200VAC, 50Hz; 200/220VAC, 60Hz, 3 phase), Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)