Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
: MPa, °C; Pressure Gauge: MPa, D: D
Stations: 03 (3 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa, D: D
Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
Size ASF Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Max.
10 One-touch Screw-in One-touch 02 03 03 Screw-in Screw-in Screw-in ZH15DA09 11 11 One-touch One-touch One-touch 09 N03 11 One-touch Screw-in One-touch N02 N03 N03 Screw-in Screw-in Screw-in ZH18DA10 12 12 One-touch One-touch One-touch 10 03 12 One-touch Screw-in One-touch 03 03 03 Screw-in Screw-in Screw-in ZH18DA11 13 13 One-touch One-touch One-touch 11 N03 13 One-touch
AS-FM AS-D AS-T ASP ASN AQ Dimensions ASV Universal type AK Applicable tubing O.D. d VCHC Applicable tubing O.D. d Weight (g) T H1 H2 D1 D2 D3 L1 L2 L3 L4 L5 (1) A (2) M1 Max. Min. Max. Min.
Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-78 5 Speed Controller Adjustable by Flat Head Screwdriver With One-touch Fitting, Elbow Type/Universal Type Dimensions Elbow type L5 D3 H (Hexagon width across flats) Applicable tubing O.D. d AS A L4 ASP D1 ASN L3 AQ ASV AK M1 ASS D2 T L1 ASR L2 ASF Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1
Length should be shorter than 5 m. Do NOT pipe upwards. AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
How to Order AD402 04 A D Semi-standard symbol: When plural options are required, indicate them in alphanumeric order.
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: D (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C
Function: 4 (3 Position Exhaust Center), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 300mm), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: D (Push-turn Locking Slotted Type), A, B Port Size: 03
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: L [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: LT [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: LT [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: LT [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display