Manifold Type: 41 (Base Mounted), Valve Stations: 5 Stations, A, B Port: C4 (ø4 One-touch Fitting)
Manifold Type: Base Mounted, Valve Stations: 5 Stations, A, B Port: ø4 One-touch Fitting, CE Marked: -
Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Passage: Common SUP, Common EXH, Side Ported, Stations: 5 Stations, Port Size: ø4 One-touch Fitting, Thread: -
Connection Port CRBU2W10 CRBU2W15 CRBU2W20 CRBU2W30 90 CRBU2W40 90 Vane type Model (size) 180 270 90 180 270 90 180 270 90 180 270 180 270 Rotating angle Single vane Double vane Volume (cm3) 1.2 1.5 2.9 3.7 6.1 7.9 15 20.2 25 31.5 41 1(0.6) 1.5(1.0) 4.8(3.5) 11.3(8.5) Side ported M5 x 0.8 Port size Axial ported M5 x 0.8 M3 x 0.5 90 100 90 100 90 100 90 100 90 100 Rotating angle Volume (cm
Specification SV1000 SV2000 Applicable series Stacking type cassette base manifold Manifold type Common SUP, EXH 1 (P: SUP)/3, 5 (E: EXH) type Valve stations (maximum) 18 stations 20 stations Max. number of solenoids 18 points 26 points 1(P)/3, 5 (E) port C8, N9 C10, N11 Port size C3, C4, C6 N1, N3, N7 C4, C6, C8 N3, N7, N9 4(A)/2(B) port Flow Characteristics Flow characteristics Port size
Valve Direction: Single Solenoid on Opposite Side of A and B Ports, Stations: 05, A, B Port Size: C4 (One-touch Fitting for ø4)
Stations: 05, A, B Port Size: C4 (One-touch Fitting for ø4)
Valve Direction: Single Solenoid on Opposite Side of A and B Ports, Stations: 05, A, B Port Size: One-touch Fitting for ø4
Stations: 05, A, B Port Size: One-touch Fitting for ø4
Hysteresis mode is selected: Refer to page 39 Window comparator mode is selected: Refer to page 40 Accumulated output mode is selected: Refer to page 41 Accumulated pulse output mode is selected: Refer to page 43 Move on to select display colour. -37No.PF-OMX0002-B Select display colour Press the or button to select the display colour. Press the S button to set.
32 to 47 CH3: Flow measurement value With symbol 16 bit 48 to 63 CH2: Flow measurement value With symbol 16 bit 64 to 79 CH1: Flow measurement value With symbol 16 bit Bit offset 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 Item CH1: Flow measurement value (PD) Bit offset 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 Item CH2: Flow measurement value (PD) Bit offset 47 46 45 44 43 43 41
Unit Standard Stroke Bore Size(mm) Standard Stroke 25 32 40 12000mm (It is possible to produce it at intervals of 1mm. ) Option Stroke Adjustment Unit Stroke Adjustment Unit 25 MY-A25L 25 MY-S25A MY-S25B 32 MY-A32L 32 MY-S25A MY-S25B 40 MY-A40L 40 MY-S32A MY-S32B 6-2 Controller Output Method None NPN Open Collector P PNP Open Collector 24 6-3 Extension Cable Length of Cable Postscript 05
. : Refer to page 41 for the seal cap. -12No.EX-OMP0013-E Power supply connector layout PWR: M12 4-pin plug, A-coded (SPEEDCON) No. Designation Description 1 SI24 V +24 V for SI unit operation 2 SV24 V +24 V for solenoid valve 3 SI0 V 0 V for SI unit operation 4 SV0 V 0 V for solenoid valve : Recommended mating M12 5-pin socket, part no. EX500-AP00and PCA-1401804.
Valve No. (1st to 4th stations) Blank plate part No. (5th station) VV3Q12-05 VQ110-5L VVQ100-10A-2 Applicable Solenoid Valve (Plug lead style) VQ1l0l-lL VQ1l0l-lM VQ1l0l-lG 1 VQ100 Series Place in front of the part No. of solenoid valve which is to be mounted. Manifold base 2 Plug lead unit Write sequentially from the 1st station on the D side.
2.91 MECHANICAL VALVES SERIES (N)VM400 3/2 MECHANICAL VALVE 18 (N)VM400 SERIES 32 Normally Open or Normally Closed Valve Many Different Actuators Cv 0.38 Flow T E C H N I C A L SPECIFICATIONS Fluid Air Operating Pressure 0 ~ 1MPa / 0 ~ 145PSI Ambient & Fluid Temperature 5 ~ 60C / 41 ~ 140F Effective Orifice (Cv Factor) 7mm2(0.38) Recommended Lubricant SMC Lubricant (ISO VG32) Port Size 1/
NARM 2500 05 A 02 G1 Optimal for central pressure control. Accessory Regulator for manifold Pressure easily set using the new handle. One-touch lock system.
characteristics chart 4 to 140F (20 to 60C) (With no condensation) Nylon 11, Nylon 12 Shore D 70 Burst Pressure Characteristics Chart 1305 Burst Pressure psi 1015 725 T0425, T0604 Other than T0425, T0604 435 Max. operating pressure (T0425, T0604) 145 0 4 32 70 105 140 Operating temperature F Max. operating pressure (Except T0425, T0604) TUB-4 Polyurethane Tubing (Inch) How to Order TIUB 05
VEX3221: M5 VEX3222: None (PA/Pilot air port) 58.6 Air operated: VEX3220 61.8 M5 (Port P2/Pilot air) Max. 10 101.7 Pg7 Applicable cable O.D. 3.5 to 7 87.9 M5 (Port P1/Pilot air) 80.4 69.1 3R 1P M5 (PE/Pilot exhaust port) P1 2A 1 59.1 58.1 102.6 64.1 1732 3 Port 3 Position Valve VEX3 Series Dimensions: Base Mounted/VEX342 External pilot solenoid: VEX3421 Internal pilot solenoid: VEX3422 41
Enclosed parts Round head screw (M4 x 6) 2 pcs. 41 Fieldbus System Series EX600 5. Marker (1 sheet, 88 pcs.) 4. Seal cap (10 pcs.) The seal cap needs to be placed the unused I/O connector. The specified protection cannot be maintained. The signal name of I/O device and each unit address can be entered and mounted on each unit.
reduction 41 to 140F (5 to 60C) Note 3) Ambient and fluid temperature Note 1) It indicates the inlet pressure for solenoid valve.