QL 11-/22-MXP12-25 Without magnet and switch rail 2-M2 x 0.4 depth 3 8 5.7 3.5 L 6-M4 x 0.7 depth 4.5 20 20 2-M3 x 0.5 depth 3.5 (mm) G H J K L M Q QL S V W Z Model 10 40 68 22 24 29 40 18 15 59 55 76 11-/22-MXP12-15 30 60 98 40 42 49 60 23 25 89 75 106 11-/22-MXP12-25 103 Precision air slide table MXP/MXPJ6 11221122Dimensions: MXP16 3 Z V K Metal stopper C 6.5 C Max. 4 25 5 Without stroke
-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K VN K Conduit terminal: T LVC LVA F (Q) 34 LVH LVD LVQ 25 U LQ R C LVN G1/2 TI/ TIL E B A H D 2-P Port size (S) PA 2-M Thread depth N PAX L PB K (mm) Electrical entry P Port size B C A D E F H K L M N Grommet:G Conduit:C Conduit terminal:T Model Q R Q R Q R S U 13.5 28 64 1/8 31 6.5
and replacement of emitters 5 q Removal of nozzle w Removal of emitter q Turn counterclockwise. w Pull forward to remove. q Turn counterclockwise. w Pull forward to remove. 6 Bypass nozzle (Option) OSHA1910.242b compliant Even if the nozzle is obstructed, the main orifice pressure cannot exceed 30 psi (210 kPa). * Supply pressure: 0.5 MPa or less 180 Gun Type Ionizer IZG10 Series Application
QL 11-/22-MXP12-25 Without magnet and switch rail 2 x M2 x 0.4 depth 3 8 5.7 3.5 L 20 20 6 x M4 x 0.7 depth 4.5 2 x M3 x 0.5 depth 3.5 (mm) G H J K L M Q QL S V W Z Model 11-/22-MXP12-15 10 40 68 22 24 29 40 18 15 59 55 76 11-/22-MXP12-25 30 60 98 40 42 49 60 23 25 89 75 106 836 Air Slide Table MXP/MXPJ6 1122Dimensions: MXP16 11223 Z V K Metal stopper C 6.5 C Max. 4 25 5 Without stroke adjuster
5 u q y e t !2 w i A CJ1 CJP CJ2 A Cylinder tube sectional view A-A !0 o CM2 CG1 Component Parts MB No. q w e r t y u i o !0 !1 No.
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
60 M10 x 1.25 16 19 24 34 34 M10 x 1.25 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12 M14 x 1.5 M14 x 1.5 12.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 CS1 23.5 23.5 C76 Bracket Combinations C85 Bracket Combinations Available Refer to table together with combination drawings.
Description Note q Material No.
NON-MOLDED MOLDED 60 HZ. 50 HZ. VOLTAGES COIL NO.
NON-MOLDED MOLDED 60 HZ. 50 HZ. VOLTAGES COIL NO.
54 9 23 55 53 28 M8 x 1.25 10 86 6.9 9.5 16 PA Bore size (mm) M MM (N) (NA) NN PB PW Q QW RB RW S T U W X Y Z 12 M4 x 0.7 M8 x 1.0 6 8 27 30 60 80 85 26 RB0806 17.5 96 13 1 77 22 7.5 5 16 M5 x 0.8 M8 x 1.0 8 8 27 45 70 95 90 40 RB0806 15 103 13 2 92 22 7.5 5 20 M6 x 1 M10 x 1.0 10 10 29 60 100 120 105 46 RB1007 26 122 17 2 117 29.5 9 5.5 25 M6 x 1 M14 x 1.5 10 12 50 60 100 130 105 50 RB1411
23 55 53 28 M8 x 1.25 10 86 6.9 9.5 16 PA Bore size (mm) M MM (N) (NA) NN PB PW Q QW RB RW S T U W X Y Z 12 M4 x 0.7 M8 x 1.0 6 8 27 30 60 80 85 26 RB0806 17.5 96 13 1 77 22 7.5 5 16 M5 x 0.8 M8 x 1.0 8 8 27 45 70 95 90 40 RB0806 15 103 13 2 92 22 7.5 5 20 M6 x 1 M10 x 1.0 10 10 29 60 100 120 105 46 RB1007 26 122 17 2 117 29.5 9 5.5 25 M6 x 1 M14 x 1.5 10 12 50 60 100 130 105 50 RB1411
q . r. lksi : Screw LXFH5BC 30 Ball t : : t l : . : : : : : t : i : : t : i ' . serie!: LXF: LXFH5BD 30 Screw LXFH5SA 30 Slide LXFH5SB 20 I LXP82BC 60 50 220 Linear ball bearing LXP82BD 60 50 90 Ball Screw 60 50 160 6 0 ' .
SI unit for VQC/S0700 series valves ( EX500-Q 01 ) 1. SI unit for SV series valves ( EX500-S 01 ) ( EX500-Q 02 ) PWR PWR COM COM 64.4 80.3 64.4 28 66 84.8 79.4 68.5 80.3 series 54.5 60 60 43.2 43 43.2 22.2 22 22.2 13 10.5 28.6 44 0 1 36 10.5 1 0 22 23 The mounting and removing methods of SI unit are as shown below.
(Use an auto switch rated 24V DC, with a minimum amperage capacity of 10mA.) q q q w w w e e e r (Unit: N) Bore size (mm) 40 50 63 80 100 Operation r Min. sensing weight 26 40 62 100 160 Warning Back-up of the balance pressure data The balance pressure data is backed up by the controller for approximately 5 minutes during a power outage or when the power supply has been turned OFF.
MGP 52 30 120 27 M8 125 65 9 9 100 84 136 120 13 15 89 32 46 95 70 75, 100 125, 150 200, 250 300 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 32 50 105 80 MGQ 70 40 160 37 M8 165 85 12 9 125 110 176 160 16 18 107 38 60 125 95 45 194 42 M10 200 95 12 11 135 115 210 190 82.5 19 23 142 50 75 150 115 MGG Bore (mm) Z Y X W WH W V U T S R Q O P MGC 20 25 32 40 50 140 80 30 30 23 36 40 86
0 q !6 r RJ10, 14, 2015, 2725 w i !2 r !3 !1 q e t y u o !0 !6 Component Parts No. Material Treatment Description No.
Without auto switch L 16 60 5 L CVJ5 L 5 L J79W 16 60 CDVJ5 With auto switch Number of auto switches Rod extended/retracted when energized Built-in magnet 2 pcs. 1 pc. n pcs.
10 to 24 SSA40 G50 Bracket mounting base port size 03 to 08 M16 x 2 x 60 D D M16 x 2 x 50 J J' 16 SSA50 G60 FH FH X X' X X' M16 x 2 x 60 M20 x 2.5 x 65 M22 x 2.5 x 65 2 x K depth L 20 24 HOW SSA65 SSA80 G75 G85 Note 1) The companion flange mounting base conforms to JIS B 2291 (21 MPa pipe flanges for hydraulic use) SSA.
0 i q o u y !7 r !9 w !4 NCY3B6 NCY3B10, 15 !4 !8 !7 !6 !5 !0 i o q u y t r !2 w !1 The above drawing is 15. (3 magnets are used in 10.) NCY3B20 to 40 !3 !4 !1 !8 !6 !5 !7 !0 i q o u t y r e w !2 NCY3B50, 63 !4 !8 !6 !5 !0 !7 i o q u y t !3 r !2 w !1 Component Parts No.