.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Valve size Valve type Port size Rated voltage A: Non-locking extended type Orifice size (mm) Symbol Symbol Symbol 3 2 1 110 VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Port size Rc Valve size 1 to 4 1 2 3 Note) N.C. N.O. C.O.
315 16.5 360.5 350 331 14.5 373 362.5 347 13 40
Mixed Mounting of VK300 and Manifold Base of Series VK3000 Type VV5K3-20 Type VV5K3-40 1. In the case of VV5K3-20/40 When installing the 3 port valve on the manifold base, plug the R port at the corresponding mark side with the rubber plug (VK3000-8-1) as shown in the figures on the right. Plug Plug 2.
Mixed Mounting of VK300 and Manifold Base of VK3000 Series Type VV5K3-20 Type VV5K3-40 1. In the case of VV5K3-20/40 When installing the 3 port valve on the manifold base, plug the R port at the corresponding mark side with the rubber plug (VK3000-8-1) as shown in the figures on the right. Plug Plug 2. Other manifold 3 port valve can be mounted without any work.
type) Displacement m Displacement m 200 200 150 150 130 120 50 50 MSZA30A (High precision type) MSZA50A(High precision type) D70 60 50 40 30 20 10 0 120 100 80 60 40 20 0 Load N Load N 291 Rotary Table Air Consumption Air consumption is the volume of air which is expended by the rotary tables reciprocal operation inside the actuator and in the piping between the actuator and the switching
30 or less 30 or less 30 or less 30 or less 50 or less 65 or less 30 or less 30 or less 30 or less 30 or less 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less 40 or less ON OFF ON OFF AC Response time (ms) (at the pressure of 0.5 MPa) DC 55 or less 40 or less 45 or less 30 or less 30 or less Note) Based on dynamic performance test, JIS B 8375-1981.
Checks and Inspection Table 2 Facility water system Circulating type Transient type Item Circulating fluid Filling of circulating fluid Transient fluid pH [25C] 6.5 to 8.2 6.0 to 8.0 6.8 to8.0 Electrical conductivity (mS/m) [25C] 80 or less 30 or less 40 or less Standard items Chloride ions (mg/L) 200 or less 50 or less 50 or less Sulfuric acid ions (mg/L) 200 or less 50 or less 50 or less
Seal kit includes a grease pack (125 to 160: 40 g, 180 and 200: 50 g, 250 and 300: 60 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) Kit no.
40 mA) 100 A or less at 24 V DC Leakage current 0.8 mA or less Indicator light Red LED illuminates when turned ON.
[%F.S.] 2.0 1.5 1.0 0.5 0.0 0 1 2 3 4 5 [s] [S] [MPa] [MPa] [MPa] [MPa] [ [ [ [ ] ] ] ] 2 69 No.LFE*-OMY0008 / / / / A B C 1 V 1.1 V 5 V 4 mA 4.4 mA 20 mA [L/min] LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 70 No.LFE*-OMY0008 2x )M12 () 1.6mm A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67
Smooth Cylinder Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure 0.04 Minimum operating pressure MPa 12 16 0.03 20 25 32 40 0.02 50 63 80 100 0.01 0 0 10 20 30 40 60 50 70 80 90 100 Bore size mm (Measurement based on JIS B8377) Series CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 Stable operation possible even at a
Low Friction Cylinders Metal Seal Type 30, 40 newly added Compact Low Friction Cylinder Series MQQ Bore size (mm) 10 16 20 25 30 40 Operating pressure range (MPa) Actuation speed (mm/s) Series MQQT Standard type 0.005 to 0.5 0.3 to 300 0.5 to 500 MQQL Lateral load resisting type (Built-in ball bushing) 0.005 to 0.7 Lateral Load Resisting Low Friction Cylinder Series MQM Series Bore size
(mg/L) 200 50 50 (mg/L) 200 50 50 [pH4.8](mgCaCO3/L) 100 50 50 (mgCaCO3/L) 200 70 70 (mgCaCO3/L) 150 50 50 (mgSiO2/L) 50 30 30 (mg/L) 1.0 0.3 1.0 (mg/L) 0.3 0.1 1.0 (mg/L) (mg/L) 1.0 0.1 1.0 (mg/L) 0.3 0.3 0.3 (mg/L) 4.0 4.0 4.0 6.07.0 1 2 JIS K 0101 2 a b c 4.2 IDF100150F-W 4 2 IDX-OM-Z004 4 (3) 1 Y Y , Y Y (4) 3 2 (5) 1( 2 3 4 a) 1. 1.5
300 100 200 300 400 Flow rate L/min Flow rate L/min (ANR) Flow rate L/min (ANR) SRH3100-02 SRH3110-02 SRH3100-02 0.5 0.20 0.20 0.4 Outlet pressure MPa 0.15 0.15 0.3 0.10 0.10 0.2 0.05 0.05 0.1 0 100 200 300 400 0 2 4 6 400 100 200 300 0 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min SRH4000-03 SRH4010-03 SRH4000-03 0.5 0.20 0.20 0.4 Outlet pressure MPa Outlet pressure MPa Outlet
Bore size Series CJ2 Pressure 0.5 MPa Load ratio 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm Series MB, CA Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load ratio 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 125 140 160 180 200 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQC1000
Regarding vessels (1) with an internal volume of 40 liters or more, or (2) with an internal diameter of trunk is 200 mm or more and its length is 1000 mm or more, procedures will be required based on the statute of Japanese labor ministry. Dimensions VBAT05, VBAT05S With booster regulator VBA1100/VBA1 connected.
(-Q) (S) 42 (-Q) VV5K3-40 (-Q) (S) 41 (-Q) (S) 42 (-Q) VV3K3-20 (-Q) 21 (-Q) VV5K3-20 (-Q) 21 (-Q) Manifold base Manifold base Caution Mounting Screw Tightening Torques M3: 0.6 Nm Body ported VK300-41-1A Base mounted VK300-41-2A Manifold gasket and screw assembly Note1) Mounting direction is fixed, do not mount on opposite side.
Bracket thickness is approx. 1.6mm Model Piping port size A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 LFE38 1 120 90 55 32 73 100 106 41 6 1.6 115 106 Model M N O P Q R S T U Bracket weight LFE13 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 Approx. 45g LFE14 48 39 4.6
ASS ASR ASF Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.