Double acting, single rod, end lock cylinder; 16mm bore; Mounting types: basic, axial foot, front flange, double clevis; Standard strokes (mm): 15, 30, 45, 60, 75, 100, 125, 150, 175, 200; Auto switch capable

Double acting, single rod; Bore size: (mm) 10, 16; Standard stroke: (mm) 15, 30, 45, 60, 75, 100, 125, 150, 175, 200; Minimum operating pressure: 0.03MPa

Solid state switches are also available in 2-color indication with diagnostic output, water resistant 2-color indication, built-in OFF-delay timer (200 ms), magnetic field resistant, heat resistant and wide range detection configurations.  Various lead wire lengths are available. Heat resistant: Max. 302°F (150°C) ; Choice of output types: PNP, NPN

Minimum operating pressure: 0.01  to 0.02 (MPa) ; Double acting, single rod ; Bore sizes: 20, 25, 32, 40, 50, 63, 80, 100 (mm) ; Standard stroke: 25, 50, 75, 100, 125, 150, 200, 250, 300 (mm)

Solid state switches are also available in 2-color indication with diagnostic output, water resistant 2-color indication, built-in OFF-delay timer (200 ms), magnetic field resistant, heat resistant and wide range detection configurations.  Various lead wire lengths are available. Heat resistant: Max. 302°F (150°C) ; Choice of output types: PNP, NPN

Double acting, single rod, end lock cylinder; 16mm bore; Mounting types: basic, axial foot, front flange, double clevis; Standard strokes (mm): 15, 30, 45, 60, 75, 100, 125, 150, 175, 200; Auto switch capable

Solid state switches are also available in 2-color indication with diagnostic output, water resistant 2-color indication, built-in OFF-delay timer (200 ms), magnetic field resistant, heat resistant and wide range detection configurations.  Various lead wire lengths are available. Heat resistant: Max. 302°F (150°C) ; Choice of output types: PNP, NPN

Controllable by a single solenoid valve; Bore sizes (mm): 40, 50; Standard stroke range (mm): 50, 100, 150, 200; 73% maximum air consumption reduction; Auto switch capable; Rod flange is mountable  

Delivery Pressure: 15 [5 to 150 psig (0.034 to 1.0 MPa)], Material: S (Body; 316 SS; Poppet; 316 SS; Diaphragm: Hastelloy® C-22 ), Ports: 3P [3 Ports (1-In; 2-Out; 5-Gauge Port Out)], Connections, Inlet: 6 (NPT 3/8 Inch), Connections, Outlet: 6 (NPT 3/8 Inch), Gauge Port, Extra Bottom Outlet: 2 [0 to 200 psig (0 to 1.4 MPa)], Gauge Port, Inlet: No Gauge Port, Gauge Port, Outlet: No Gauge

Delivery Pressure: 15 [5 to 150 psig (0.034 to 1.0 MPa)], Material: S (Body; 316 SS; Poppet; 316 SS; Diaphragm: Hastelloy® C-22 ), Ports: 3P [3 Ports (1-In; 2-Out; 5-Gauge Port Out)], Connections, Inlet: 4 (NPT 1/4 Inch), Connections, Outlet: 4 (NPT 1/4 Inch), Gauge Port, Extra Bottom Outlet: 2 [0 to 200 psig (0 to 1.4 MPa)], Gauge Port, Inlet: No Gauge Port, Gauge Port, Outlet: No Gauge

auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Head Cover Port Position: Basic Integrated Clevis, Rod End Bracket: None, Type of Mount Support: None, Rod Boot: None, Custom-made Specifications: Heat-resistant cylinder (150°C)

type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Type of Mount Support: Rod-end flange type, Custom-made Specifications: Heat-resistant cylinder (150°C), Material of Gasket: FKM

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Specification: Built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Specification: Built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Specification: Without built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~0.7, Specification: Without built-in magnet, Support bracket: Through-hole

magnet, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Type of Mount Support: Basic type, Rod Boot: Without rod boot, Custom-made Specifications: Heat-resistant cylinder (150°C)

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket