Specifications .11 3. 1 Specifications.11 3. 2 Details of parts.13 3.3 Outside dimension diagram.14 (1) Screw mount type (LECGE1).14 (2) DIN rail mount type (LECGE1D).14 3.4 How to install.15 (1) How to install.15 (2) Installation location .15 4.
ISA-2-1 ISA-2-2 ISA-2-3 ISA-2-4 ISA-2-5 ISA-2-6 ISA-2-7 ISAl-1 ISAl-2/ISAl-1 ISAl-3/ISAl-2 ISAl-4/ISAl-3 ISAl-5/ISAl-4 ISAl-6/ISAl-5 ISAl-6 No.
C4SF-J C4SF-W C4SF-6 AD47-6 AD48-6 C4SF-6J C4SF-6W C4SF-2 AD47-2 AD48-2 C4SF-2J C4LF-8 AD47-8 AD48-8 C4LF-8J C1SF-6 AD17-6 C1SF-2 AD17-2 C2SF-C AD27-C C2SF-J C2SF-CJ C2SF-6 C2SF-6C AD27-6 AD27-6C C2SF-6J C2SF-6CJ C2SF-2 AD27-2 C2SF-2J C3SF-J C3SF-W C3SF-6 AD37-6 AD38-6 C3SF-6J C3SF-6W C3SF-2 AD37-2 AD38-2 C3SF-2J C3LF-8 AD37-8 AD38-8 C3LF-8J Polycarbonate Nylon Metal Metal bowl
CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD SG 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector. 12 SG Note 1) Do not orient diodes incorrectly
A B C D A B C D Bore size (mm) Port aperture A 12 (1) (1) (1) CUJ 16 (2) (2) (2) CU B D 20 (2) (2) (2) View from piston rod end 25 CQS (2) (2) (2) 32 C (2) CQM 40 (2) CQ2 50 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (2) RQ Operating Range Auto Switch Mounting
IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B J A C D E F G H I , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3 x M5 x 0.8 x depth 6 3 x M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 950
IDG20 IDG60, 75, 100 With cap bolts (2 pcs.) and spring washers (2 pcs.) 2 Series IDGC) Note 1) Range of operating conditions Standard performance
Note 2) The dimensions are the same as the standard type. MHY MHW Heat Resistant Specifications 2 Grooves for Auto Switch on Both Sides 4 -X41 -X4 MRHQ MHK D 1 L 2 Bore size X4 F MHK 2 L D 1 F Bore size X41 Misc.
2 !3 !4 Component Parts Material Material Note Note No. q w e No. i o !0 !1 !2 !3 !4 !
THREAD W M R C G J Q P K N 2 A Bowl Detail U (AF20) H L E IN OUT D Bracket (Optional) Note: Sight glass not applicable to AF20.
Width across flats of attachment 3/8 24 mm 1/2 27 mm 3/4 32 mm 1 41 mm 11/4 54 mm 11/2 54 mm Tighten to the specified torque for piping. The tightening torque for connection threads is shown in the table below.
DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR SIGNAL OUTPUT . 12-1 12.3 REMOTE OPERATION . 12-2 12.4 CONNECT THE POWER CABLE AND SIGNAL CABLE . 12
Through-hole/Both ends tapped common (Basic) 10 0.1 0.2 Q 12 (Rod size) G M5 x 0.8 (2 locations) (Port size) Auto switch Minimum bending radius of lead wire 10 R 4 3 E Yh9 S T 3 F M8 x 1.25 Effective thread depth 11 6.8 (The dimension on the opposite side is the same.) 5.5 (2 locations) 13.6 7 10 7 10 M6 x 1 (2 locations) Flat washer With 2 pcs. 9 (2 locations) (The dimension on the opposite
T) View Z Dimensions (N.O valve, double acting valve) (mm) A B C D M N T U V Model LVQ2 -S-2 LVQ3 -S-2 LVQ4 -S-2 LVQ5 -S-2 LVQ6 -S-2 2 1 25.5 46 31.5 58 7 15 35.3 10.6 7 2 1 23.5 47 29.5 59 7 15 36.9 16.5 10 2 1 23.5 47 29.5 59 7 20 37.9 22 2 1 17 35 70 41 82 7 20 64 25 2 1 35 70 41 82 7 20 66 32 17-5-72 11 Space Saving/Space Saving Connection Series LVQ How to Order VC LVQ 2 0 S 07 S VDW
thread 30 D C H B (mm) C d D H B Part no.
r^rE_aEIl_I ItrtrElEll+trMElr cG1 C D G l T T series i I .2: 3. .4, i.5. .6-l '?
: SYJA5240-01 2 x 4.3 (For mounting) 44 2 x M5 x 0.8 (Pilot port) VGA 37.5 4 1 2 x M5 x 0.8 (Pilot port) 11 B A 5 VPA 1 A B 1 10 M5 x 0.8 (A, B port) 2 x 2.6 (For manifold mounting) 24 A B VPA3 19 1 P R Manual override 54 2 42 47 54 Manual override 23 20 15 3 11 2 x 2.6 (For mounting) 11.5 45 2 x 1.3 (Breathing port) 33.5 M5 x 0.8 (P , R1, R2 port) 21.5 6 6 P R1 17 17 15 8.5 R2 45.5 1/8 (
B Q L2 L3 L4 L5 L6 L1 H 1(P) 2(A) C D E F G J K 1(P) R 2(A) 2(A) R 3(R)* VHK-01S-M5 VHK-M5-M5 11 1.2 26 23 11 3.5 41 18 54 51 11 M5 M5 M5 VHK-B1A 44.5 14.5 1 27 22 16.5 26 2.0 2.0 29.1 16.5 29 29.1 61.6 58.2 1 8 11 3.5 41 8.6 1.2 13 18 13 VHK-B1A 44.5 14.5 1 27 22 16.5 26 32.6 16.5 VHK-01S-01S 1 8 1 8 30 57 32.6 65.2 VHK-02S-01S 18 41 71.6 39 32.6 39 78 16.5 3.5 11 9.0 9.7 1.2 39 13 47 62
25 25 6 x M3 x 0.5 thread depth 6 (A, B, C common view) +0.02 0 (A, B, C common view) 3 x 3 depth 6 34 12h9 0 0.043 1.5 5 19.5 12 41.5 (45) 8 17 2 2 8 0 0.05 3.5 0 0.03 3.5 0 0.03 Open: 22 Closed: 14 2 x M3 x 0.5 thread depth 6 (Thread for mounting attachment) 15 15 6 5 5 6 498 Series MHR2/MDHR2 Rotary Actuated Air Gripper 2-Finger Type With auto switch (Built-in magnet) : MDHR2-15R
and Both ends tapped common): MQQTB 10, 16, 20 H thread effective depth C 2-M5 x 0.8 2 x 4-OA effective depth RA 2 x 4-OB Counterbore depth RB F Q Y I 4-N through 0.2 D E M L B + Stroke K 0.2 A + Stroke M E 25, 28 H thread effective depth C 2-Rc 1/8 F Q Y 2 x 4-OB Counterbore depth RB 2 x 4-OA effective depth RA J I 4-N through 0.2 D W E M K L B + Stroke 0.2 A + Stroke M E Bore size (mm)