6 ( 12 4 5 7 2 1 3 17 14 1 2 A 3 B 4 + 5 6 + 7 + 8 9 10 A 11 B 12 13 NBR 14 15 16 17 18 ( DC24V) 4 - 4.
. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure
46 mm, Width: .79 in / 20 mm, Height: .81 in / 20.5 mm, Net Weight: .07 lbs. / .03 Kg Series Configured Datasheet.
mm, Width: .79 in / 20 mm, Height: .81 in / 20.5 mm, Net Weight: .07 lbs. / .03 Kg Series Configured Datasheet.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base EX250 type manifold for SV1000 valves, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 07 Station Manifold, Tie-Rod Base. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 07 Station Manifold, Tie-Rod Base. 0.61 lb. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 07 Station Manifold, Tie-Rod Base. 0.67 lb. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 07 Station Manifold, Tie-Rod Base. 590 lb. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. "SS5V 07 Station Manifold.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 07 Station Manifold, Tie-Rod Base.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. "SS5V 07 Station Manifold.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. "SS5V 07 Station Manifold.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 07 Station Manifold, Tie-Rod Base.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX500 type manifold for SV2000 valve, Decentralized serial wiring, IP67 protection, Number of outputs: 16, Maximum 16 stations available as standard, Optional DIN rail mount, 6 port sizes available "SS5V 07 Station Manifold. 4/5 PORT SOLENOID VALVE. N lb. SV.
SS5V 07 Station Manifold, Tie-Rod Base. 0.47000 lb.
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor],
Manifold Mounting: Direct Mount, Centralized Supply (IN) Piping Position: Top, Regulator Block Stations: 6 Stations, IN/OUT Fitting Type: 07 [IN/ø6 (Straight) - OUT/ø4 (Straight)], Accessories: w/Pressure Gauge/L Side, Options: 0.35 MPa Setting, Unit Representation: Display Unit for Product Name Plate and Pressure Gauge: PSI
Manifold Mounting: Direct Mount, Centralized Supply (IN) Piping Position: Bottom, Regulator Block Stations: 6 Stations, IN/OUT Fitting Type: 07 [IN/ø6 (Straight) - OUT/ø4 (Straight)], Accessories: w/Pressure Gauge/L Side, Options: None, Unit Representation: Display Unit for Product Name Plate and Pressure Gauge: PSI
Manifold Mounting: Direct Mount, Centralized Supply (IN) Piping Position: Top, Regulator Block Stations: 6 Stations, IN/OUT Fitting Type: 07 [IN/ø6 (Straight) - OUT/ø4 (Straight)], Accessories: w/Pressure Gauge/R Side, Options: -, Unit Representation: -
Manifold Mounting: DIN Rail Mount, Centralized Supply (IN) Piping Position: Bottom, Regulator Block Stations: 6 Stations, IN/OUT Fitting Type: 07 [IN/ø6 (Straight) - OUT/ø4 (Straight)], Accessories: w/Pressure Gauge/L Side, Options: None, Unit Representation: Display Unit for Product Name Plate and Pressure Gauge: PSI