SMC Corporation of America
Elite Part Number Search
Search Results "ISE20A-T-01"

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø4 One-touch Fitting, Straight Type, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø1/4" One-touch Fitting, Straight Type, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø4 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø1/4" One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Straight Type, Lead Wire: -, Bracket: -, Operation Manual: -

Also, do not use the filter when these chemicals are present in the atmosphere. 2 Series ZB How to Order Manifold S 01 ZZB 08 M5 Stations Pressure Sensor/Vacuum Pressure Switch Mountable Note) Sensor/switch non-mountable base Sensor/switch mountable base Nil S 01 02 1 station 2 stations Note) Select S when the model with either the pressure sensor or the vacuum pressure switch is selected

VCHC AS1201F-M3, AS1211F-M3 AS1301F-M3, AS1311F-M3 AS1201F-M5-02, AS1211F-M5-02 AS1201F-M5, AS1211F-M5 AS1301F-M5, AS1311F-M5 AS2201F-01, AS2211F-01 AS2301F-01, AS2311F-01 ASS Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa ASR ASQ Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Number of needle rotations Number of needle rotations Number of

AS1201FM, AS1211FM AS1301FM, AS1311FM AS2201FM-01, AS2211FM-01 AS2301FM-01, AS2311FM-01 AS2201FM-02, AS2211FM-02 AS2301FM-02, AS2311FM-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 20 10 50 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 40 30 10 5 20 10 0 5 20 10 10 0 5 0 10 Number of needle rotations Number of needle rotations Number

PFM7-C4/C6/C8/N7--X693 PFM7S-C4/C6/C8/N7--X693 PFM7-01/02--X693 PFM7S-01/02--X693 -73No.PF-OMJ0006-J PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 PFM7-01/02--X694 PFM7S-01/02--X694 -74No.PF-OMJ0006-J For a mixture of Argon (Ar) and carbon dioxide (CO2) The mixture ratio can be selected from Ar : CO2 = 92 : 8, 90 : 10, 80 : 20, 70 : 30 or 60 : 40.

ASS AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 ASR ASQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG AS431FG

AK AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 VCHC Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa ASR ASQ 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG

Example: In case of 6 stations of air suction filter ZFA100-01 ZZFA1-06 1 pc. (Brackets for 6 stations) ZFA100-01 6 pcs. (Air suction filter) 276

2 N NPN1 P PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L 2m -8No.PS-OMS0006CN-G / A ZS-46-A1 3X8L (2 ) B ZS-46-A2 3X8L (2 ) ZS-46-B + ZS-46-D ZS-46-3L 3 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch ZS-46-N7H 4mm ZS-46-C4L 6mm ZS-46-C6L 1/4 inch ZS-46-N7L -9No.PS-OMS0006CN-G LCD LCD 4 ON/OFF ON