SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-P-P-N01"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: T (w/o Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: None, Option 3: T (w/o Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type)

Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type)

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type), Bracket: A5 (Bracket E for M12 Connector Type)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type), Bracket: A5 (Bracket E for M12 Connector Type)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Socket/Plug: P (Plug), Thread Port Size: N01 (NPT 1/8), Barb Fitting Port Size: Not Applicable, Nut Fitting Port Size: Not Applicable, One-touch Fitting Port Size: Not Applicable, Connection Type: F (Female Thread)

Socket/Plug: P (Plug), Thread Port Size: N01 (NPT 1/8), Barb Fitting Port Size: Not Applicable, Nut Fitting Port Size: Not Applicable, One-touch Fitting Port Size: Not Applicable, Connection Type: MS (Male Thread w/Sealant)

.: ZS-46-D) psi P ZSE20A(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.

Safety Instructions Bracket A ISE20B Bracket B Display color Output ON: Green/Output OFF: Red (Linked to OUT1) P psi ZSE20B(F) : Arbitrary display OUT1 hysteresis OUT1 set value Mode display These safety instructions are intended to prevent hazardous situations and/or equipment damage.