SMC Corporation of America
Elite Part Number Search
Search Results "HRSH100-AN-20-AS"

Not installable Food zone An environment where food which will be sold as merchandize, directly touches the fitting components. Installable Splash zone An environment where food which will not be sold as merchandize, directly touches the fitting components. An environment where there is no contact with food.

If using in an environment that is exposed to water splashes, please take measures such as using a cover. Do not use in an environment where moisture or water vapor are present. Otherwise failure and malfunction can result. Do not use in a place where the product could be splashed by oil or chemicals.

Since the dimensions of mounting style is the same as pages 6-4-13 to 6-4-20, refer to those pages.

Otherwise an unexpected malfunction of the system can occur due to a malfunction of the monitor. Perform a proper functional check after maintenance. Stop operation when an abnormality is observed such that the device does not work properly. Otherwise an unexpected malfunction of the system component can occur. Do not use solvents such as benzene or thinner to clean the monitor body.

Note 3) To lubricate the outlet side of VY, use VY as an external pilot. Avoid lubrication to the pilot air. IC VBA VE VY1 Option Part no.

If using in an environment that is exposed to water splashes, please take measures such as using a cover. Do not use in a place where the product could be splashed by oil or chemicals. If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction etc.).

(Figure-20-3) Fix the cylinder with screws included as accessories after confirming that there is no interference between the lever and the proximity switch. Figure-20-1 Figure-20-2 Figure-20-3 20 - 9. Troubleshooting Detail of trouble Cause Countermeasure Operation is not smooth 1. Lubrication failure Clean components and apply specified grease to them. 2.

Fitting Connection Series AN10 to 30-C RoHS How to Order 10 C AN 20 Applicable one-touch fitting size Body size Symbol Port size Applicable model AN10 AN10 AN15 AN20 AN20 AN30 Symbol 10 15 20 30 06 07 08 10 11 12 6 1/4 8 10 3/8 Connection type 12 Symbol Connection type C One-touch fitting connection Specifications Fluid Compressed air Max. operating pressure Note 1) 145psi (1.0 MPa) Noise

If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires). Do not use in an area where electrical surges are generated.

If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires). Do not use in an area where electrical surges are generated.

Bore size/Stroke (mm) 6 10, 20, 30, 40, 50 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Adjuster option Nil Without adjuster Functional option AS Extension end adjuster AT Retraction end adjuster Nil Standard A Both ends adjuster P Note) Axial piping CS Extension

Full scale Same meaning as F .S. Full span Same meaning as F .S. D Detection range Distance at which an instrument such as the Air Catch Sensor is operational. G Gas contact part Wetted parts. Parts that are in contact with the process gas.

Main applications Cotton Stainless steel 304 20 to 100 0.5, 1, 5, 10, 20, 50, 75, 100 0.2 MPa 0.1 MPa Polypropylene Polypropylene 0 to 60 0.5, 1, 5, 10, 20, 50, 75, 100 Glass fiber Stainless steel 316 1, 5, 10, 20 0 to 400 Note) Size for all is 65 x L250. Different lengths are available as a special order up to 750 mm, only for cotton and polypropylene. Elements Part No.

to 350 L/min Display flow range (Flow under 0.35 L/min is displayed as 0.00) (Flow under 1.7 L/min is displayed as 0.0) (Flow under 3.5 L/min is displayed as 0.0) (Flow under 7 L/min is displayed as 0) (Flow under 20 L/min is displayed as 0) Set flow range Minimum setting unit 0.35 to 5.50 L/min 1.7 to 22.0 L/min 3.5 to 55.0 L/min 7 to 140 L/min 20 to 350 L/min 0.1 L/min 0.01 L/min 1 L/min

by the following formula: = 10 x mg = 20 x mg mg F = x a 2 x 10 x Workpiece weight 20 x Workpiece weight Even in cases where the coefficient of friction is greater than = 0.2, for reasons of safety, select a gripping force which is at least 10 to 20 times greater than the workpiece weight, as recommended by SMC.

Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).

To prevent a malfunction, implement counter measures such as using a single EXH spacer assembly or an individual exhaust manifold.