Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: ABK (w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option: ABK (w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: W (SI Unit Only)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: F [G, (w/Rc-G Conversion Fitting)], Option: AK (w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: B1 (w/Earth Leakage Breaker w/Handle)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: AB1K (w/Caster Adjuster Foot and w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: AB (w/Caster Adjuster-foot and Earth Leakage Breaker)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: AB1 (w/Caster Adjuster Foot and w/Earth Leakage Breaker w/Handle)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: AB1KW (w/Caster Adjuster Foot and w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port and SI Unit Only)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: B1K (w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: B1KW (w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port and SI Unit Only)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: AK (w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: F [G, (w/Rc-G Conversion Fitting)], Option: AK (w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill)
This information is needed when contacting an SMC sales distributor. THERMO CHILLER HRS050-A-20 POWER SUPPLY SERIAL No.
MM KK A B D E F GA GB K L 075 (3/4") 0.250 1/4-28 0.50 0.624 0.86 0.38 0.250 0.75 0.34 106 (1 1/16") 0.312 5/16-24 0.50 0.624 0.25 1.12 0.38 0.250 0.75 0.12 0.34 150 (1 1/2") 0.437 7/16-20 0.75 0.749 0.38 1.56 0.62 0.375 1.00 0.25 0.50 200 (2") 0.625 1/2-20 0.88 1.374 0.50 2.06 0.75 0.38 0.56 Note) The clevis pin for NCMC200 is not included.
D-864 Bone Sizes Rod Boot o75 -%', 088 -',6' 106 -1%6" 125 -114" 't50 -1%' J -Nylon K -Neoprene Astuation -Double Acting S -Spring Return T -Spring Extend srror,.rrn"r, Sirokg/Hundrlh ol an lnch Cushion' C -Rubber Bumper Note: Min. Strokes for Auto Switch Cylinders page 5. *Rubber Bumpers are no additional cost on 7s" & 174" bore size cylinderg. Thy are options on the other bore sizes.
HA J K L MM ML NN OA OB OL P PA PB PW Q R S T U VA VB Nil TN TF 32 9 102 M6 22.5 22.5 31 M8 x 1.25 20 M8 x 1.25 6.7 11 9 Rc1/8 NPT1/8 G1/8 6.5 14.5 34 26 86 39.5 100 74 88 63 40 12 112 M6 24.5 24.5 35 M8 x 1.25 20 M8 x 1.25 6.7 11 9 Rc1/8 NPT1/8 G1/8 16 16.5 41 28 92 42 106 82 98 72 50 12 140 M8 29.5 29.5 43 M10 x 1.5 22 M10 x 1.5 8.6 14 9 Rc1/4 NPT1/4 G1/4 13 19 49 35 115 52.5 133 104 122