As an example, for a travel of 100 (mm) Travel distance of the actuator per 1 pulse = 0.001 (mm) *1 100 (mm)/0.001 (mm) = 10 (pulse) If the stroke end signals (LSP, LSN) are not turned ON, an alarm may occur.
Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker
Type: Thermo-Chiller, Cooling Method: Water Cooling, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker
Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)
20 20 34 M5 female thread 1/4 female thread Note) In the case of Rc, G: 10 In the case of NPT: 3/8 Drain Drain Drain Drain guide Drain cock Auto-drain Series AFF Series AM, AMD, AMG, AMH Size Size 2B 4B A B C Note) Select in accordance with the type of thread on the main body.
If the power should not come back on, please contact SMC for an inspection.
Metric size 2 3.2 4 6 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
(Supply pressure 0.3 MPa) External air inlet Compressed air External air inlet Yes None Reduced by 50% Air consumption flow rate L/min (ANR) 10 10 Ionized air Discharge time sec 2.5 2.5 5 Compressed air Improved 6 times Ionized air flow velocity m/s 0.4 At 300 mm distance External air inlet External air Neutralizing static electricity from an electric substrate Neutralizing static electricity
Note2) A (set) side energization : A light (orange) illuminates, B-(reset) side energization : B light (green) illuminates.
50 3-5 depth 10 +0.02 0 16h9 0 0.043 (A, B, C common view) Misc.
Insert the holding block (A) (8) into the groove of the cover (A) (9), place the cover (B) (10) on top, and fasten the cross recessed round head screw (11). 4. Insert the auto switches (2) into the switch blocks (A) (12) and (B) (13) and mount them to the holding block (B) (14) using the cross recessed round head screws (16).
10 6 0.01 0.1 0.01 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L (mm) Overhang L (mm) Overhang L (mm) Graph b b Load Eccentricity 100 mm Graph , Load Eccentricity 100 mm Graph 1 Load Eccentricity 100 mm 1 10 10 Mass m (kg) Mass m (kg) Mass m (kg) 1 20 16 20 16 20 16 10 6 0.1 1 10 0.1 10 6 6 0.01 0 20 40 60 80 100 0.01 0.1 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L
The element retainer shall be assembled in such a way that the symbol A-A in (a) of Fig. 6 is overlapped with symbol B-B of element retainer shown in (b) of Fig. 6 in parallel. B A B A C View of c Actuators Modular F.R.L.
The element retainer shall be assembled in such a way that the symbol A-A in (a) of Fig. 6 is overlapped with symbol B-B of element retainer shown in (b) of Fig. 6 in parallel. B A B A C View of c Actuators Modular F.R.L.
Piping adapter Spacer with Bracket Mounting Position Dual residual pressure release valve (-X538) Dual residual pressure release valve with soft start-up function (-X555) (Max. 10) 201.8 82.9 (14) (14) 201.8 (Max. 10) 82.9 IN OUT IN OUT d c b a d a b c Model a b c d Note Model a b c d Note VP544-5DZ1-03-X538 33.9 57.2 95.7 220.7 AW30-03G-A Y300T-A E300-03-A VP544-5DZ1-03-X555 33.9 57.2 129.2
A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5
A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5