SMC Corporation of America
Elite Part Number Search
Search Results "E400-06-A"

33 B A 33 B D-A3 D-G39/K39 D-A3C D-G39C/K39C G 1/2 (Applicable cable O.D. 6.8 to 9.6) Auto switch G 1/2 HW A 49 B (Applicable cable O.D. 6.8 to 9.6) Hs 49 Hs 34 56 S M C A U T O S W I T C H S M C A U T O S W I T C H A 36 B 36 Auto switch D-F5/J5 D-F5NTL D-F5W/J59W D-F5BA/F59F D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL Hs Auto switch Hs Auto switch Hs Ht 24.5 SMC SMC Ht A 30 (33) B 14 A 33 B

switch model D-A44 D-A44C D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5/A6 D-F5W D-J59W D-F5BAL D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W D-A3/A3C D-A44/A44C D-G39/ G39C D-K39/K39C D-B5/B6 Bore size (mm) Bore size (mm) A B A B A B A B A B A B A B Hs Hs Hs Ht Hs Hs Ht Hs Hw Hs Hw 31 40 40 40 81 9.5 2 10.5 0 72.5 31 4 8.5 2 69 0 0.5 11.5 1.5 38 73 69 38.5 0 0 80.5 3.5 35 43.5

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

BA-08 BA-10 D-B7/B80 D-B73C/B80C D-G79/K79 D-K79C BM1-01 BM1-02 BM1-32 BM1-04 BM1-05 BM1-06 Note) Two kinds of auto switch mounting brackets are used as a set.

Therefore, the repair service shall be available on a chargeable basis if a failure is detected after the warranty period. Revision Rev.

Position (Standard type) Auto switch model D-Y59l D-Y69l D-Y7P D-Y7PV D-Y7H D-Y7lW D-Y7lWV D-Z7l D-Z8l D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-F5l D-J59 D-F59F D-F5NT D-A5l D-A6l D-A59W D-G39 D-K39 D-A3l D-A44 D-A9l D-A9lV D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5 4.5 11.5 9.5 0 0 4 2 0 0 3.5 1.5 5.5 3.5 3 1 40 9 9 5 5 5.5 5.5 10.5 10.5 0 0 3 3

Rotate the pin 30 to the right with a wooden implement such as the grip of a wooden hammer or a resin stick without scratching.

SGH(A)32-7020 SGH(A)42-7025 SGH(A)13-3010 SGH(A)23-3015 SGH(A)33-3020 SGH(A)43-3025 SGH(A)13-7010 SGH(A)23-7015 SGH(A)33-7020 SGH(A)43-7025 3/8 7.5 42 (1.8) 1.4 1.5 1/2 9.4 65 (2.7) 2.4 2.6 7 MPa 2-port 3/4 12.4 112 (4.7) 4.7 5.3 1 15.4 155 (6.5) 6.6 7.2 3/8 9.4 50 (2.1) 56 (2.3) 1.6 1.7 11 1/2 10.5 55 (2.3) 73 (3.0) 1.6 1.7 3 MPa 15 3/4 12 90 (3.8) 92 (3.8) 2.6 2.8 17 1 15.2 135

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

(mm) Flow characteristics Av x 106m2 Cv factor Port size Model converted Air operated type External pilot solenoid type SGC(A)22ll-05l10 SGC(A)22ll-05l15 SGC(A)32ll-05l20 SGC(A)42ll-05l25 SGC(A)22ll-10l10 SGC(A)22ll-10l15 SGC(A)32ll-10l20 SGC(A)42ll-10l25 SGC(A)22ll-16l10 SGC(A)22ll-16l15 SGC(A)32ll-16l20 SGC(A)42ll-16l25 0.73 (0.78) 0.73 (0.78) 1.08 (1.15) 1.74 (1.81) 0.73 (0.78) 0.73 (0.78

Diaphragm B moves to the right, and at the same time diaphragm A also moves to the right pushing pilot valve A. 3. When pilot valve A is pushed, air acts upon the switching valve, drive chamber A switches to a supply state, and the air which was in drive chamber B is exhausted to the outside. 4. When air enters drive chamber A, diaphragm B moves to the left pushing pilot valve B. 5.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

Cover Rod cover Unit holding tie-rod A (2 depth 1 mm hole is on the side of tie-rod for attaching unit A.)

Cover Rod cover Unit holding tie-rod A (2 depth 1 mm hole is on the side of tie-rod for attaching unit A.)

D-H7NF D-H7BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-C7/C8 D-C73C D-C80C D-C73C D-C80C D-B5/B6 D-G59F D-B59W A B B B B B B A A A A A Hs Hs Hs Hs 20 25 32 40 50 63 80 100 35 Series MGG Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height/End Lock Type: With Rod End Lock A B 8.5 Hs 11.5 16 Auto switch D-C7/C8 D-H7 A B 12 Hs 14.5 Courtesy of Steven Engineering

AS 0 0.1 0.15 0.2 0.25 0.3 Return stroke pressure (MPa) ASP ASN v v w w a a o o l l v v l l F F e e AQ ASV u u r r e e s s v v s s a a e e l l v v r r P P e e AK ASS ASR ASF Working stroke Working stroke Return stroke Return stroke Pressure valve Flow valve 15-16-1 Cuts air consumption by operating the return stroke at a reduced pressure.

A Parts list Section A enlarged view Description Material Note No.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

M8 x 1.25 M10 x 1.5 Model Applicable cylinder MY3A16, MY3B16 MY3A25, MY3B25 MY3A40, MY3B40 MY3A63, MY3B63 A B A B A B A B MY-S16 MY-S25 MY-S32 MY-S40 63.6 Data 091 130 182 Guide for Using Side Support For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight.