ZA A B t 2 x D ZX C ZM ZL ZH ZH ZH ZH -X267 ZH13 to 20DA 2 x D B ZHP A F E C ZU VQD-V Long clamping screw set for 1 station required for assembly needs to be ordered separately.
P I S T O N R O D A I R H Y D R O TYPE P I S T O N R O D D E F L E C T I O N (REFERENCE FACTOR) P I S T O N R O D D E F L E C T I O N (REFERENCE FACTOR) For a concentrated load at the center of the housing. For a concentrated load at the center of the end plate.
cable O.D. 6 to 8 (D, DL) Pilot port B (Air operated) L (Terminal with indicator light: DL) M (Conduit terminal: T) K (DIN terminal: D) I (Grommet: G) J (Conduit: C) 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H I J K L M Model VNB5-32F VNB6-40F VNB7-50F 1 8 1 4 1 4 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 244 259.5
ZZ + Stroke Model B C D E(h8) I K L NA Q x R S TC x R W X ZZ REA50 REA63 0 86 32 53 30-0.033 32-0.039 58.2 25 110 55 M8 x 1.25 x 16 176 M12 x 1.25 x 7.5 60 60 180 100 38 66 72.2 26 122 69 0 M10 x 1.5 x 16 188 M14 x 1.5 x 11.5 70 70 192 Mounting nuts/2pcs. packaged with each cylinder d C H d B C Part No.
Auto switch model 2 (Same side) 2 (Different sides) 1 2 1 D-C7/C80 Band mounting style Rail mounting style 50 15 10 D-H7/H7W 60 15 10 D-H7NF D-C73C/C80C Note) Small round head screws 65 15 10 D-H7C Plate D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V D-J79C D-A79W/F7W D-J79W D-F7WV/F79F Solenoid valve 10 5 Pipe gasket 5 5 15 10 2.
A B C D E F Model no. A B C D E T Use 2 spanner flats when fixing the foot to the motor. Recom m ended setscrew: M6 4pcs. 4 Knock pin 2pcs. Use (1)(across flat) when fixing the foot at the rod. L[]ZB[]3 119.5+st 69.7+st 4 6.8 L[]ZB[]5 155.5+st 92.7+st 4 7 Model no.
Confirm the position where the pushing operation starts. a b c d e f g h i j k No.
Note) 200 V type only. 400 V type is provided with an earth leakage breaker as standard. 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) HRZ Specifications HRZD Model HRS090-Wl-20-l HRS090-Wl-40-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.15 Control method PID control Ambient temperature1 C 5 to
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com c B part e f d 2.
mounting style Rail mounting style 15 stroke 80 121 D-H7/H7W 15 60 10 30 stroke 88 140 Basic weight D-H7NF 45 stroke 98 164 D-C73C/C80C Note) 15 65 10 60 stroke 110 189 D-H7C Axial foot style 7 19 Mounting bracket weight D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V D-J79C D-A79W/F7W D-J79W D-F7WV/F79F 10 Rod side flange style 5 13 5 Mounting nut and rod end nut are included in the basic
(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)
(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
ULUL1310Class2 6.2 2) AWG20(0.5mm (24V0V) 60 2) EMG AWG20(0.5mm (EMG+,EMG-) 60 8mm 21 - D (100) D 6.3 (CN2SW)ON (EMG+,EMG-) (LEC)EMG (CN2SW) RY CN4 CN2 EMG+ EMG24V 0V (CN2SW)ON EMG+,EMG-(LEC)OFF (LEC)(EMG+,EMG-) 22 - (LEC) ()LEC6 DC24V 0V Ry EMG+ Ry EMG(1 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (2 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3 ) BK RLS EMG Ry C 24V 24V M
50/60 Hz 9 Other Option How to Order Pilot Valve Assembly External pilot 00 VT3113 G 1 Coil rated voltage Electrical entry 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz G Grommet Conduit terminal DIN terminal TL D T Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot. 4 Conduit terminal with indicator light TS Conduit
Stainless Steel (mm) A B C D E F G H J L Bracket part no.
wire length 0.6 m Nil Grommet type Lead wire length 3 m L NPN open collector, double output Analog, no output, 200 degree setting 17 Lead wire length 0.6 m C Connector type Lead wire length 3 m CL NPN open collector, single output Analog, with output, 3 turn setting 18 Without connector CN NPN open collector, single output Analog, with output, 200 degree setting 19 With connector/How to
(per unit) Applicable model A B C D HRSE012-AHRSE018-AHRSE024-A240 (335) 505 (540) HRW HRS-TK003 HECR HRSE012-A--T HRSE018-A--T HRSE024-A--T 240 (335) 555 (590) HEC HEB HED HEA IDH Anchor bolt (M8) D C (Prepared by user) Anti-quake bracket Material: Zinc steel plate Mounting view A B w Bypass Piping Set Note) To be mounted by user.
Auto Switch Specifications Grommet PLC: Abbreviation for Programmable Logic Controller D-F9W/D-F9WV (with indicator light) D-F9PW D-F9PWV D-F9BW D-F9BWV D-F9NW D-F9NWV Auto switch part no.