How to Order Standard B 20 30 D C CQSY B 20 30 D C F9BW S CDQSY With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.

(per unit) Applicable model A B C D HRSE012-AHRSE018-AHRSE024-A240 (335) 505 (540) HRW HRS-TK003 HECR HRSE012-A--T HRSE018-A--T HRSE024-A--T 240 (335) 555 (590) HEC HEB HED HEA IDH Anchor bolt (M8) D C (Prepared by user) Anti-quake bracket Material: Zinc steel plate Mounting view A B w Bypass Piping Set Note) To be mounted by user.

OFF ON OFF Point input B OFF Point input C Time chart OFF Point input D ON Emergency stop input + OFF Actuator speed OFF Alarm reset input Bank input 1 OFF Bank input 2 OFF Point output A OFF Bank input 3 ON OFF OFF Point output B OFF Point input A ON OFF Point output C OFF Point input B OFF Point output D OFF Point input C ON Alarm output OFF Point input D ON READY output ON Emergency stop

Controller (VYU5-D) External appearance of exclusive controller RUN1 STOP START SEL. SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.

Controller 1 JXC 7 D T LEFS16B-100 Communication protocol Actuator part number Precautions for blank controllers (JXC1-BC) Without cable specifications and actuator options Example: Enter LEFS16B-100 for the LEFS16B100B-S1mm.

N.O. 1 (P) 3 (R) 1 (P) 3 (R) a c e d a c e d (A) (A) 2 2 g g 3 (R) 1 (P) 3 (R) 1 (P) b b f f Component parts Replacement parts Note Zinc die-casted No.

D-F9WV D-F8 Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E 18.5 31 6.5 20.5 41 8.5 20.5 33 4.5 17 20.5 31 4.5 15 20.5 41 4.5 15 20.5 51 4.5 35 22.5 43 6.5 27 22.5 33 6.5 17 22.5 43 6.5 27 22.5 53 6.5 37 MIW12-12D MIW20-20D 6 4 4 2 18.5 29 6.5 20.5 31 8.5 MIS12-10D MIS20-10D 4 2 6 4 2.5 4 18.5 39 6.5 20.5 41 8.5 MIS12-20D MIS20-20D 6 4

D-F9WV D-F8 Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E 18.5 31 6.5 20.5 41 8.5 20.5 33 4.5 17 20.5 31 4.5 15 20.5 41 4.5 15 20.5 51 4.5 35 22.5 43 6.5 27 22.5 33 6.5 17 22.5 43 6.5 27 22.5 53 6.5 37 MIW12-12D MIW20-20D 6 4 4 2 18.5 29 6.5 20.5 31 8.5 MIS12-10D MIS20-10D 4 2 6 4 2.5 4 18.5 39 6.5 20.5 41 8.5 MIS12-20D MIS20-20D 6 4

OFF ON OFF Point input B OFF Point input C Time chart OFF Point input D ON Emergency stop input + OFF Actuator speed OFF Alarm reset input Bank input 1 OFF Bank input 2 OFF Point output A OFF Bank input 3 ON OFF OFF Point output B OFF Point input A ON OFF Point output C OFF Point input B OFF Point output D OFF Point input C ON Alarm output OFF Point input D ON READY output ON Emergency stop

Can be changed 5 At the time of shipment Analog output [V] 1 0 1050 100 10% of rated flow range 10 1000 100% of rated flow range Maximum display range Flow [L/min] 1000 L/min type Error display function When an error or abnormality arises, the location and contents are displayed.

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-15 Connection of RS-232C HRSH Series 3.3 Installation 3-27 HRX-OM-Q026 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.

PWR COM D D D D D D 3 2 1 Station D side How to Order Solenoid Valves SV 1 1 0 0 F 5 Note) Note) Available with manifold block for station addition. Refer to pages 77 and 81 of SV catalog (ES11-81A).

How to Order Applicable Valves VQ 1 0 5 0 Y 1 B Series VQ1000 A B C D Type of actuation Function Manual override C D A Nil Non-locking push type (tool required) Slotted locking type (tool required) Knob locking type (manual type) B C Specifications 1 2 3 4 5 Symbol 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center DC Nil Standard

Number of auto switches Without auto switch C 16 ZCUK D 20 S 1 pc. C S D 16 D 20 ZC UK M9B With auto switch Auto switch Built-in magnet Nil Without auto switch Style (Tubing method in vacuum side)/ (Rod end shape) Refer to the table below for applicable auto switches.

IDX-OM-W011-B / Series IDF1E/2E/3E-10(-A,C,S) IDF3E-20(-A,C) IDF4E-10(-A,C,L,M,R,S,T) IDF4E-20(-A,C,L,M,R,T) IDF6E-10(-A,C,K,L,M,R,S,T) IDF6E-20(-A,C,K,L,M,R,T) IDF8E-10(-A,C,K,L,M,R,S,T) IDF8E-20(-A,C,K,L,M,R,T) IDF11E-10(-A,C,K,L,M,R,S,T) IDF11E-20(-A,C,K,L,M,R,T) IDF15E1-10(-A,C,K,L,M,R,S,T) IDF15E1-20(-A,C,K,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded

bolt B at ot ot (For clockwise rotation end adjustment) 5 5 r r 9 se 9 e e is e wi g w g n n k k ra oc c a o t r cl cl en nt er er e tm e m nt nt is us u t u w C 0 us o 90 k o c lo o C l dj C C 19 dj se c Cl 1 A k A A wi e w oc ge dj k A is oc k ng dj u wi e Cl an st us se ro ra m r ta t ot m r d at ti n e n io on e n e on nt e nt tio nd r r a a ti n n g ta e 5 9 g ta e 9 ro 5 ro m m

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.

VQ1 1 0 5 L Vacuum pressure switch ZQ1S D AS 31 C Solenoid valve VQ1 ZQ1 2 0 5 L Electrical entry Switch specifications Actuation Connector type 31 32 51 52 1 NPN output and analog output 2 NPN outputs 1 PNP output and analog output 2 PNP outputs 2 Normally open C Lead wire length: 0.6 m Connector type Pilot valve CL Lead wire length: 3 m Nil Standard type (1W) CN Without connector Rated

D-B7/B80 D-B73C D-B80C D-G79/K79 D-K79C Auto switch model D-B7/B80 D-B73C D-B80C D-G79/K79 D-K79C D-H7C D-G5NTL D-G5W D-K59W D-G5BAL D-G5 D-K59 D-G5NTL D-H7W D-H7BAL D-H7 D-H7C/H7NF D-C7/C80 D-C73C D-C80C D-C73C D-C80C D-B5/B64 D-G59F D-B59W Applicable bore (mm) Hs Hs Hs A A A A A B B B B B B 16 (24) A 21.5 (29.5) 20.5 (28.5) 15.5 (22.5) 17.5 (25.5) 19.5 (27.5) 20 27.5 27 24.5 25.5 29 27

The additional air blow can be set to continuous or pulse (50/100 ms intervals). Ionizer Additional air blow Air blow Ionized air 497 ZVB Series Dimensions C B D A C B A D F E [ZVB20] F E [ZVB40] Model A B C D D Note 1) E F F Note 2) ZVB20 211 202 212 310 351 210 297 341 ZVB40 248 392 298 349 390 400 384 428 Note 1) Dimension D is the overall height including the knob of the regulator.