1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s MY2C MY2 H/HT Maximum Load Mass Select the load mass from within the range of limits shown in the graphs.
(Values at the initial period) Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
D A B Side support B MY-SB 2 x J MY1B MY1B MY1H E A B MY1B C D MY1M (mm) MY1C A 61 70 87 B C D E F G H J Part no.
D A B Side support B MY-SB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-J C D A B (mm) A 61 70 87 B 75 84 105 C D E F G H J Part no.
D A B Side support B MY-SB 2-J C D A B (mm) A 61 70 87 B 75 84 105 C D E F G H J Part no.
400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 1000 0 200 400 600 800 Flow rate ( /min (ANR)) Relief flow rate ( /min (ANR)) Supply pressure P1 (MPa) 14-5-11 11 Series IR1000/2000/3000 Series IR3000 Flow Characteristics Relief Characteristics Pressure Characteristics Testing methods conform to JIS B 8372.
Slider type LEFS series 2.1 Specification LEFS25,32,40 AC servo motor (100W / 200W/400W/) Model LEFS25 LEFS32 LEFS40 Stroke [mm] Note 1) 50800 501000 1501200 Work load [kg] Note 2) Work load [kg] 10 20 20 30 40 45 30 50 60 Vertical 4 8 15 5 10 20 7 15 30 400 1500 900 450 1500 1000 500 1500 1000 500 401 500 1200 720 360 1500 1000 500 1500 1000 500 501 600 900 540 270 1200 800 400 1500 1000
1000 20 to 1000 35 32 70 27 81 108 1/4 1/4 52 20 40 95 17 27 59 13 12 11 M8 x 1.25 7 18 80 63 Up to 1000 20 to 1000 35 32 86 27 101 115 1/4 1/4 64 20 40 102 17 26 67 18 15 11 M10 x 1.25 7 18 99 80 Up to 1000 20 to 1000 40 37 102 32 119 129 1/4 1/4 78 25 52 113 21 30 72 23 17 13 M12 x 1.75 10 22 117 100 Up to 1000 20 to 1000 40 37 116 41 133 140 1/4 1/4 92 30 52 124 21 31 76 25 19 16 M12
) (1000) (1000) MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000) (900) (1000) (900) MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1MW16 MY1CW16 MY1CW16 (900) (900) (900) Caution 20 20 10 10 1.
Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.
Flow Characteristics Series Flow characteristics C [dm3/(sbar)] b Cv 0.089 0.32 0.72 0.31 0.41 0.38 0.36 1.2 2.7 SYJ300 SYJ500 SYJ700 Cover (stainless steel) 4-4-1 2 3 Port Solenoid Valve Rubber Seal Series SYJ300/500/700 Series Variations Option Series Port size Sonic conductance C [dm3/(sbar)] Manual override Type of actuation Voltage Electrical entry With light/surge voltage suppressor
70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
How to Order Port Number e r KT12 L C 4P 8 1 Installation option Delivery pressure Code Installation Bottom mount (Standard) Panel Installation Delivery pressure Code 5 to 120 psig (0.034 to 0.83 MPa) 5 to 300 psig (0.034 to 2.1 MPa) 5 to 600 psig (0.034 to 4.1 MPa) 10 to 1000 psig (0.07 to 6.9 MPa) 15 to 1500 psig (0.1 to 10.3 MPa) 25 to 2500 psig (0.17 to 17.2 MPa) No code P B E G I J L
D-A44 Conduit , _;-c' I>-F5CJ51!:1 Grommet D-F5i!
Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the
Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the
Without air cushion Foot type/ (L) Bore size (mm) Cushion valve Port LS ZZ 32 40 50 63 80 100 134 138 156 156 184 188 168 176 198 201 240 244 LH LY 4-LD LT (mm) Foot type ZZ + Stroke LS + Stroke X Y X Y LX Bore size (mm) Stroke range X Y LD LH LS LT LX LY LZ ZZ LZ 32 40 50 63 80 100 700 800 1000 1000 1000 1000 9 11 11 14 14 16 22 24 27 27 30 32 7 9 9 12 12 14 30 33 40 45 55 65 128 3.2 3.2
D Side support B MY-SB 2 x J A B C D A 61 70 87 B 75 84 105 C D E F G H J Part no.
How to order L E C C G 1 L Cable length(L) K 0.3m L 0.5m 1 1m ii. Dimensions 70 - (3) Cable between branches (between the branch connectors) i. How to order L E C C G 2 L Cable length(L) K 0.3m L 0.5m 1 1m ii. Dimensions (4) Branch connector i. How to order L E C C G D Branch connector ii. Dimensions (5) Terminating resistor i. How to order L E C C G R ii. Dimensions 71 - 8.
NT-02 NT-03 NT-G04 (15) (19.6) (21.9) M8 x 1.25 M10 x 1.25 M14 x 1.5 12.5 16.5 18 13 17 19 20 25, 32 40 5 6 8 20 C type 8 for shaft C type 8 for shaft IY-G02 0.040 0.076 8 16.2 21 7.6 0.9 1.5 20 CD-G02 0.040 0.076 8 38.6 1.5 43.4 7.6 0.9 C type 10 for shaft C type 10 for shaft IY-G03 20.2 25.6 9.6 1.15 0.040 0.076 10 1.55 25, 32 0.040 0.076 10 CD-G25 42.6 1.55 48 9.6 1.15 25 C type 10 for