(Unit: %) H 140 80 80 Sets the position loop P constant. *Please perform the actuator operation after changing this parameter setting under the responsibility of the user. Position loop P constant A 140 110 110 1 to 200 B 100 80 80 C 110 80 80 H 80 140 140 Sets the speed loop P constant.
H HW C 44 52 64 78 92 H' T T' Z Actuator series 50 63 80 100 D-A3lC-4, D-A44C-4 D-A3lC-5, D-A44C-5 D-A3lC-6, D-A44C-6 D-A3lC-8, D-A44C-8 D-A3lC-10, D-A44C-10 58(67.5) 50.5(60) CDA1, CDBA1, CDV3, CDVS, CDLA, CDL1, CNA 69 77 91 107 121 6.5 6.5 7.5 9.5 9.5 40 50 63 80 100 7.5 8.5 10.5 12.5 15.5 M5 X 0.8 X 16 9 10 11 11 11 59(68.5) 51.5(61) 61.5(71) 53(62.5) M5 X 0.8 X 20 65(74.5) 54.5(64) Note
A System error P-1 Internal data error H-1 Internal data error Min. B Nonabsorption H Unit display switching function Work 1 Work 2 Work n Atmosphere Display units can be switched with this function. Units that can be displayed vary depending on the range of the pressure sensors connected to the controller.
A System error P-1 Internal data error H-1 Internal data error Min. B Nonabsorption H Unit display switching function Display units can be switched with this function. Units that can be displayed vary depending on the range of the pressure sensors connected to the controller.
C B R H J H IN OUT OUT IN OUT OUT A P Min. clearance for maintenance A Min. clearance for maintenance AL10, AL20 AL30, AL40, AL40-06, AL50, AL60 Applicable model Drain cock with barb fitting With drain cock With drain cock Metal bowl Metal bowl with level gauge Metal bowl with drain cock Metal bowl with drain cock Metal bowl with drain cock & level gauge Optional B specifications B B B B
Pin name 1 2 3 4 DC (+) OUT2 DC () OUT1 1 3 2 x Piping port Z U T S 4 x WX G 2 4 (35.5) 42 H For PF3W721 OUT IN AA G 4 x P K L 2 x Piping port G N DD PF3W504/520/540/511/521 Remote sensor unit Y A E J F 30 W B V 2 x Piping port Z S T U 4 x WX G H 42 (35.5) For PF3W521 IN OUT AA G 4 x P K L 2 x Piping port G N (mm) Bracket dimensions Model Port size A AA B D DD E F G H J K L N P (Rc, NPT,
Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
Note 3) Bowl assembly for AL30 to AL60 comes with a bowl guard (steel band material). 52 AL10 to 60 Dimensions AL10 AL20 L D Bracket (option) G F Port size K M A Port size C B R C J H OUT OUT IN OUT OUT IN B R P Min. clearance for maintenance Min. clearance for maintenance A AL50, 60 AL30, 40 L D D L Port size Bracket (option) Bracket (option) G F G F Port size M K M K E J C B R C B R H
Real-time flow rate P Window comparator mode H : Hysteresis H H ON Flow rate confirmation display NO OFF P-1 P-2 This function allows the accumulated flow rate confirmation when real-time flow rate is selected, and the real-time flow rate confirmation when accumulated flow rate is selected. Real-time flow rate OUT1 Output mode Hysteresis mode ON YES OUT2 is the same.
For EX600/EX250 pp. 63, 77, 119 1 3 5 S6 S JJ5SY 10 G P, E port entry, SUP/EXH block assembly P, E port entry External pilot U side (2 to 10 stations) G D side (2 to 10 stations) H Both sides (2 to 24 stations) J How to Order Valves JSY T 0 0 5 1 R 3 5 R JSY 0 0 5 Coil type (See below.)
Lube Unit/ALDU600-06 to 10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4
Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.
Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.
AL7 T h e r m o s t a t (0.1C) 0.0 Sets lower limit of temp measured by the internal temp sensor and stops operation of the product. 0.0 to 59.0C A H Do not make any modification to the product. Do not disassemble the product, unless required by installation 11 Ambient temperature is too high. (out of 10-35oC) Correct the ambient temperature within the specification range.
(Unit: %) H 150 100 Sets the position loop P constant. *Please perform the actuator operation after changing this parameter setting under the responsibility of the user. Position loop P constant A 150 100 1 to 200 B 150 100 C 90 100 H 130 140 Sets the speed loop P constant.
H 50 MHT2 Overhang H (mm) Overhang H (mm) MHW2-20D 150 MHW2-25D MHW2-32D MHW2-40D MHW2-50D 40 MHY2-10D MHY2-16D MHY2-20D MHY2-25D MHY2 Holding point 30 100 MHW2 20 50 10 MRHQ 0.4 0.5 0.6 0.7 0 0 0.1 0.2 0.3 0.1 0.2 0.4 0.5 0.3 0.6 Auto switch Pressure P (MPa) Pressure P (MPa) Holding point Work should be held at a point within the range of overhanging distance (H) for a given pressure indicated
h Grommet terminal i Conduit terminal j DIN terminal a Model b d e f VEX5510 VEX5511 19 130 110 9 12 2.3 204 204.5 222 221.5 32 VEX5710 VEX5711 136 120 9 20 2.3 221 221.5 239.5 239 VEX5910/5911 Bracket (Option) Pressure gauge (Option) Grommet terminal (E) DIN terminal (D) Applicable O.D. 6 to 8 Conduit terminal (T) 1/4 (P2) 1/4 (P1) Refer to page 2449.
C D (KF) KF (K) KF G I H H V Fn Fd A C C U U M E V V A L E B K S H J M G A A A B C D E Fn Fd G H J K XLD-25 50 123 48 1 12 40 26 41 16 7.5 XLD-40 65 170 66 2 11 55 41 63 20 15 XLD-50 70 183 79 2 11 75 52 68 20 17.5 XLD-63 88 217 100 3 11 87 95 70 72 20 20 XLD-80 90 256 117 3 11 114 110 83 98 20 26.5 XLD-100 108 321 154 3 11 134 130 102 133 20 38 XLD-160 138 335 200 3 11 190 180 153 114
ON/OFF / / 2 3 3 2 1 2 / -20- 3.3. [] LEC LEC / P.32 5.3 <> NPNPNP LEFS16A-100 NPN <> INPIN []INP ON ON INP ON OFF -21- <> No.1 01 a b c d e f g h i j k a ABSINC No. 1 2 mm/s mm mm/s2 mm/s2 % % mm/s % mm mm mm 0 ABS 250 50.00 3000 3000 0 0 0 100 48.00 50.00 0.50 1 ABS 250 0.00 3000 3000 0 0 0 100 0.00 2.00 0.50 ABS()/ / INC()// b c d e f 00 g h i 100%DC24V 250% j 12
Micromist separator AMD900, 1000, 901 Model Connect (Flange) 2B 2B/3B/4B 400 A 280 B 6B C 550 D 150 E 270 F 823 G 3 H 797 J 620 AMF801 AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 Mounting Caution q Verify the direction of the flow of the compressed air and the "e" mark that indicates the inlet of the product before connecting.