Leakage Enclosure: IP65 1 x 10-10Pam3/s
: 2 to 10 stations U side: 2 to 10 stations Nil Standard length (Specify a longer rail than the standard length.)
For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3
Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M5 x 0.8 AS231FG-01 AS221FG-01 R 1/8 AS231FG-02 AS221FG-02 R 1/4 AS331FG-02 AS321FG-02 R 1/4 AS331FG-03 AS321FG-03 R 3/8 AS431FG-04 AS421FG-04 R 1/2 AS131FG-U10/32 AS121FG-U10/32 10-32 UNF AS231FG-N01 AS221FG-N01 NPT 1/8 AS231FG-N02 AS221FG-N02 NPT 1/4 AS331FG-N02
B-1 A-1 B-2 A-2 B-3 A-3 B-4 A-4 Connector D terminal no. 12 13 7 6 9 8 11 10 3 Circuit Cable color Shield Vcc GND A A B B Z Z Brown Black Red Black Orange Black Yellow Black Connector B terminal no.
Maximum Ejector Stations (Max. operable nos. simultaneously) Ejector model ZMA053 ZMA054 ZMA073 ZMA074 ZMA103 ZMA104 ZMA133 ZMA134 ZMA153 ZMA154 Manifold model R L 10 8 5 4 3 ZZMA Stations 06 10 10 8 6 5 ZZMA Stations 06B R L 10 8 5 4 3 ZZMA Stations 04 10 10 8 6 5 ZZMA Stations 04B Effective area of external silencer is 160 mm2.
] 50 Hz Power consumption Note 6) 760 1390 1700 (W) Operating current Note 6) 4.3 6.1 7.9 (A) 10 20 Applicable circuit breaker capacity Note 5) (A) Air-cooled Condenser R407C (HFC) Refrigerant Refrigerant charge 0.42 0.73 0.55 0.67 (kg) Float type (Normally open) Auto drain R 1 R 11/2 Port size R 2 Accessory Symbol Weight 100 116 54 62 (kg) Body panel: White 1 Base: Gray 2 Coating color
0 A !3 !2 !1 o i t !0 !3 !2 !1 o i e t !0 A A e u w y q B C P2 P1 OUT IN P1 w y u B q w y u B q P2 OUT C C IN VXD2272/2382/2392 (32A to 50A) VXD2270/2380/2390 (32A to 50A) !4 !5 !3 !1 i t e !2 !0 A r u B y q !3 !2 !1 i t e o !0 A r u B y q w o w C C Operation
ASS Dimensions ASR AS220M-01 02 AS120M ASF H 8 (Hexagon width across flats) L1 T2 24.8 (MAX. 29.8) 28.2 (MAX. 33.2) M5 x 0.8 L2 A L3 D1 9 10.3 10 M5 x 0.8 10-32 UNF D2 T1 9 Dimensions A L2 L3 T1 T2 H L1 D1 D2 Model Min. Min. Max. Max.
IDX-OM-W025-A PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF22E-20(-A,C,K,L,M,R,T) IDF22E-30(-A,C,K,L,M,R,T) IDF37E-20(-A,C,K,L,M,R,T) IDF37E-30(-A,C,K,L,M,R,T) IDF55E-30(-A,C,L,M,R,T) IDF75E-30(-A,C,L,M,R,T) Please read this manual prior of using the air dryer. Keep the manual readily available for reference. To Customers Thanks for purchasing SMC Refrigerated Air Dryer.
A 24, 12, 6, 5, 3 Coil rated voltage V DC 100, 110, 200, 220 AC 50/60Hz P R P R 10% rated voltage Allowable voltage 0.5 (With light : 0.55 ) Power consumption W Note) DC 0.9 ( With light : 1.0) 100V External pilot 110V [115V] 1.0 (With light : 1.10) [1.1 ( With light : 1.2) ] SYJ71 R 2 4 SYJ72 R 2 4 Apparent power VA AC 1.8 (With light : 1.9) 200V A X A X 1.9 (With light : 2.0) [2.2 (With
Note 3) The value at a temperature of 20C, with a 10% or less O.D. variable rate.
Applicable tubing M L1 KFG2 KFG2 6 4 5 9 10 16 5.8 3.3 H1 d MS 8 6 14 12 14 18.4 6.6 5.3 A L2 H2 KKA H3 10 7.5 25 6.8 KP Connection thread 15 17 21.4 7.6 10 8 29 7.3 LQ MQR 12 9 38 23 8 16 17 8.5 T 12 10 48 24.5 9 IDK 16 13 86 21 22 26.7 9.3 12 Reference dimensions after installation of R thread 325 KFG2 Series Applicable Tubing: Metric Size, Connection Thread: R, Rc Dimensions Female Connector
) A B Coil voltage 24 VDC 5 P EA EB 3 position closed center A B 3 Function Note 1) EAPEB Standard type (1 W) External pilot Low wattage type (0.5 W) Nil R Y 3 position exhaust center A B Note 2) 4 Note 1) When specifying more than one option, enter symbols in alphabetical order.
MXQ12-10 MXQ12-10 MXQ12-10 MXQ12-10 0.01 0.02 0.004 0 0 0 160 40 80 120 20 40 60 80 100 20 40 60 80 100 Load (N) Load (N) Load (N) 8-5-12 13 Air Slide Table Series MXQ Table Displacement due to Pitch Moment Load Table Displacement due to Yaw Moment Load Table Displacement due to Roll Moment Load Displacement at A when a load is applied to F with the slide table retracted.
Allow a margin for safety to decide use of the product. 7.5.1 Cooling Capacity 30 Ambient temperature25 Recirculating fluid level180 (At recirculating fluid temp. 25) Cooling water temp.25 Cooling water flow rate3L/min Shut out from outside with a lid (styrofoam) Recirculating fluid temperature 25 20 15 10 5 0 Water R GALDEN HT200 -5 -10 FluorinertTM FC-3283 -15 -20 0 20 40 60 80 100 120
Note 3) 10 to 15 in decimal number are displayed as follows in the 7-segment LED. Decimal display 10 11 12 13 14 15 Hexadecimal display A b c d E F Note 4) Applicable to non-magnetizing lock. 65 Programless Controller Series LECP1 Precautions Model Selection Details of The Controller e r Details No.
IDX-OM-W026-A / Series IDF22E-20(-A,C,K,L,M,R,T) IDF22E-30(-A,C,K,L,M,R,T) IDF37E-20(-A,C,K,L,M,R,T) IDF37E-30(-A,C,K,L,M,R,T) IDF55E-30(-A,C,L,M,R,T) IDF75E-30(-A,C,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 *1) JIS B8370 *2 ) *1) ISO4414Pneumatic fluid power General rules and safety requirements
Setting rotation time I n e r t i a m o m e n t K i n e t i c e n e r g y E x t e r n a l s t o p p e r I n s t a l l p o s i t i o n o f e x t e r n a l s t o p p e r C auti on on usi ng exte rnal stoppe r R o t a r y a c t u a t o r w i t h A u t o s w i t c h A u t o s w i t c h s p e c i f i c a t i o n A u t o s w i t c h i n s t a l l a t i o n A u t o s w i t c h s
flat 10 Width across flat 10 A A 10 10 2 2 1.8 1.8 8.4 6 Dimensions (per stroke) Dimensions (per stroke) 10 13 Weight (g) Non-rotating (J) Rotating (K) Weight (g) Non-rotating (J) Rotating (K) 14 11 A B D A B D Model Model ZP3-T13B;3-B5 ZP3-T13B;6-B5 ZP3-T13B;10-B5 ZP3-T10B;3-B5 ZP3-T10B;6-B5 ZP3-T10B;10-B5 8.5 9.7 11.7 8.6 9.8 11.8 8.6 9.7 11.7 8.7 9.8 11.8 15 18 22 34.5 41 51 11 14.5 20.5