Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
14 (E) Position number 1 (End side) 2 (Motor side) 3 4 5 6 7 8 9 10 (A) 11 (B) 12 (C) 13 (D) 14 (E) 50 Series LECP2 Signal Timing (1) Positioning Operation [Driving to the stroke end] (4) Stop by the STOP Signal 24 V 0 V 24 V 0 V Power supply Power supply ON OFF ON OFF IN0 or 1 IN0-3 Input Input ON OFF OUT0 or 1 STOP Output ON OFF BUSY OUT0-3 Release Hold BUSY External lock Output ALARM
V O Speed max 10ms ON OFF BUSY BUSY ON OFF max 60ms V O Speed Response time with respect to controller input signals Timing for alarm reset The following requisites exist for delay of response with respect to controller input signals.
Wash the bowl with mesophile washing solvent. ., 0.6 -" r--:-::-I---t 0.5 -:--. 0.2 S'H~-t-_t---t--t--t--+---t---"-lH ' io'H--+~;j-~V~ds~ -" Set point d" OA r---.. -::; i"'-8Avoid use in direct sunlight. Q) ~ 0.3 1 '"' l' Q. Q) Q. Cautions on Use o ~ ~ 0 0.2 I:". When the primary pressure has been released, the residual pressure (secondary pressure) cannot be removed.
X2568 15 15 30 30 45 45 60 60 75 75 90 90 105 105 120 120 135 135 Clamp arm position L (Left side mounting) R (Right side mounting) R L D Right Left Both sides Switch cassette Switch cassette * Proximity switch mounting surface viewed from the front.
Applicable tube O.D. (1) "Eibow": M3, M5 only (UL standard V-0) 4 6 8 10 12 04 06 08 10 12 Built-in One-touch fittings Applicable model: ASV310F, ASV410F, Port size ASV510F M3 X 0.5 M5 X 0.8 R(PT)1/8 R(PT)1/4 R(PT)3/8 R(PT)1/2 M3 M5 01 02 03 04 P Brass parts are all electroless nickel plated. AS ASN AQ Model ASV 4 6 8 10 12 Applicable tube O.D. (mm) Effective area (mm2) IN OUT OUT EXH.
Symbol Port size Rated flow range 501 102 202 04 1/2 V V 06 3/4 V Note 7) Each option is not assembled with the product, but shipped together.
IDX-OM-W017-E / Series IDFA3E-23-A,C IDFA4E-23-A,C,L,R,T,V IDFA6E-23-A,C,K,L,R,T,V IDFA8E-23-A,C,K,L,R,T,V IDFA11E-23-A,C,K,L,R,T,V IDFA15E1-23-A,C,K,L,R,T,V URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 *1) JIS B8370 *2 ) *1) ISO 4414: Pneumatic fluid power General rules and safety requirements for systems and
VZ 1 (P) 3 (R) VS VFN Latching type (A) 2 1 (P) 3 (R) Clean Series Clean series is available for both standard and option specifications.
FH99-FL006-N V FH99-FL004-N V FH990-04 FH99-FL006-N V FH99-FL005-N V FH990-06 FH99-FL009-N V FH99-FL007-N V FH990-08 FH99-FL009-N V FH99-FL008-N V FH990-10 One set each of companion flange, seal, hexagon socket head cap screws FH99-FL011-N V FH99-FL010-N V w Operation The hydraulic fluid used becomes high viscosity when the temperature is low during the winter, etc., and the differential
Note 2) The seal is for 40 m and 80 m elements. 784 Vacuum Filter AFJ20 to AFJ40 Series Dimensions AFJ20 N T J M D U Bracket (Option) S SP R ZCUK C B V Q IN OUT AMJ AFJ AFJ 2 x P (Port size) AMV ZH -X185 Related Products Clearance for maintenance G A AFJ30, AFJ40 N T J D M U Bracket (Option) S R C V Q IN OUT 2 x P (Port size) B Clearance for maintenance G A E Model Standard specifications
J K Note 1) 4 x Sa Thread depth Sb 2 x L O H I N G A M Vacuum flow Dust bag When dust bag is mounted T F E D Suction air Discharge air Suction air U C C B Hose band V (mm) A 73 B 34 C 19 D 10 E 13.2 F 16.2 G 69.8 H 31 I J 35 K 27 L 4.5 M 35 N 18 O P 13 Q Rc1/8 R 28 Sa M3 x 0.5 Sb 5 T 300 U 150 V 190 Model ZH10--X185 ZH20--X185 4 1 M4 x 0.7 8 400 200 250 119.5 55 32 15 19.5 23.5 111 48 56
Specify the wiring specifications on the manifold specification sheet. 12 12 stations Note 1) U D U D Note 2) Note 3) 2-6-10 11 Base Mounted Series VQ5000 Plug-in Unit Electrical wiring specifications Standard wiring D-sub connector assembly (AXT100-DS25) Wire colors 015 030 050 D-sub connector Terminal no.
Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) 5 to 50C (Air operated type: 60C) PA AC (50/60 Hz) DC VNC1 VNC Applicable pressure range 100 V, 200 V, Other voltage (Option) Coil rated voltage (V) 2 4 PAX 24 V, Other voltage (Option) 15% to +10% of rated voltage Class B or equivalent (130C) 1 4 VNC Allowable voltage fluctuation Coil insulation type Pressure VNC2 PB External
of ge ge an an n r tio ta n r Ro +8 0 io Ro tat tat Ro 80 io t 1 n r fla an ge gle of sin +10 0 Ro tat 90 ion t 1 ra fla ng le e o ing f s With external stopper For 90 For 180 Single flat Single flat A n 5 5 gl e ge ge ad an an ju t r t r st en m en en stm m t r st ju ju an ad ad ge le e Ang 5 gl n A B port A port B port A port 90 A 5 n gl ge e an ad t r ju en st m 180 Note) The drawings
ad an an ju t r t r st en m en en stm m t r st ju ju an ad ad ge le e Ang 5 gl n A B port A port B port A port 90 A 5 n gl ge e an ad t r ju en st m 180 Note) The drawings show the rotation range for the shaft's single flat.
4.5 1 1 Note) There is no protrusion for sections of the table with no values entered. 6.5 6.5 6.5 6.5 0.5 0.5 3 3 1 1 4.5 4.5 4.5 4.5 1 1 6.5 6.5 6.5 6.5 0.5 0.5 3 3 1 1 Hysteresis MHF2-8D D-M9(V) D-M9W(V) MHK MHF2-8D1 Red ON Green ON MHF2-8D MHS 0.5 0.5 1 MHF2-8D2 MHF2-12D 0.5 0.5 1 MHC MHF2-16D 0.5 0.5 1 MHF2-12D MHF2-20D 0.5 0.5 1 MHT MHF2-12D1 MHY Mounting of Auto Switch MHF2-12D2
4.5 1 1 Note) There is no protrusion for sections of the table with no values entered. 6.5 6.5 6.5 6.5 0.5 0.5 3 3 1 1 4.5 4.5 4.5 4.5 1 1 6.5 6.5 6.5 6.5 0.5 0.5 3 3 1 1 Hysteresis MHF2-8D D-M9(V) D-M9W(V) MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tubing O.D. 9 Selection Procedure V x 60 Q Adsorption response time T1 = When the suction flow rate of 53 kPa is obtained from the ZH07DS flow characteristics graph, the leakage volume is 5 l/min (ANR). () Leakage: Adsorption flow (5 l/min) (ANR) Adsorption response time T2 = 3 x T1 Piping capacity 3.14 4 1 1000 V = D 2 x L x ( l ) Example 2: For obtaining the discharge response time until