SMC Corporation of America
Elite Part Number Search
Search Results "10-RECG20-150"

150 50 50 75 40 40 ZH 100 50 30 30 20 20 50 ZU 25 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10 10 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.1 0.2 0.3 0.4 0.5 0.6 ZL Supply pressure (MPa) Supply pressure (MPa) ZY Flow Characteristics Flow Characteristics Supply pressure

66 17 10 218 80 22 10 218 80 19 10 241 90 25 10 241 90 21 10 277 100 30 10 334 150 40 13 13 16 16 19 19 22 22 32 100 63 113 76 119 76 145 90 151 90 166 106 173 106 200 122 253 160 8 12 6 40 66 84 28 5 2.0 27 37 1/4,3/8 172 AMH250 178 1/2 8 12 6 40 66 84 28 5 2.0 27 37 3/8, 1/2 204 AMH350 3/4 210 8 14 7 50 80 100 34 5 2.3 32 37 8 14 7 50 80 100 34 5 2.3 32 37 10 14 9 55 88 110 50 9 3.2 37

Impact acceleration [m/s] 5 0 50 100 150 200 250 300 Speed [mm/s] Relationship between speed and impact acceleration Features 1 in vacuum environments (1.3 x 10-Pa) Carefully designed for low particulate generation, low leakage, and low outgassing.

40 80 50 50 20 20 Load mass m (kg) Load mass m (kg) Load mass m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.

temperature [C] 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] For the high-pressure pump (Option), the heating capacity increases by approx. 10 W.

Option Bracket J: With drain guide (Option) female thread T: With element service indicatior Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35

Nut assembly (9) XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 Valve size Description Part indication No.

-57 Hz: 0.075 mm Constant Amplitude 57-150 Hz: 9.8 m/s2 Acceleration Sweep Count for X,Y,Z: 10 times (80 minutes in each direction) Conforms to IEC 68-2-6; 10-57 Hz: 0.15 mm Constant Amplitude 57-150 Hz: 19.6 m/s2 Acceleration Sweep Count for X,Y,Z: 10 times (80 minutes in each direction) 9 PneuAlpha Hardware Specification 2 Table 2.8:Environmental and Electrical Specications Insulation Resistance

Nut assembly (9) XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 Valve size Description Part indication No.

Bellows assembly (7) XL1A16-2-101 XL1A25-2-101 XL1A40-2-101 XL1A50-2-101 Nut assembly (9) XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 Valve size Description Part indication No. Bellows assembly (7) XL1A63-2-101 XL1A80-2-101 Nut assembly (9) XL1A50-10-1 XL1A80-10-1 Note 1) Bellows assembly contains the valve seal 1. It does not contain the valve seal 2.

Suction flow rate Suction flow rate [l/min (ANR)] Air consumption [l/min (ANR)] Suction flow rate [l/min (ANR)] Air consumption [l/min (ANR)] Suction flow rate 250 125 Vacuum pressure [kPa] Vacuum pressure [kPa] 80 80 70 70 200 100 60 60 Air consumption Air consumption 150 50 50 75 40 40 100 50 30 30 20 20 50 25 10 10 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 1.0 2.0 3.0 4.0 5.0 6.0 Supply pressure

Value range: 10 10, in 1 ms increments Unit: ms F_WD_Time 150 A CRC signature, which is calculated automatically via all F-Parameters and ensures error-free transmission of the F-Parameters.

Bellows assembly (7) XL1A16-2-101 XL1A25-2-101 XL1A40-2-101 XL1A50-2-101 Nut assembly (9) XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 Valve size Description Part indication No. Bellows assembly (7) XL1A63-2-101 XL1A80-2-101 Nut assembly (9) XL1A50-10-1 XL1A80-10-1 Note 1) Bellows assembly contains the valve seal 1. It does not contain the valve seal 2.

800/220 1200/350 / AC200V 2400/150 3200/220 4800/350 XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 ( 30 10 XL-OMY0002 . 1 S 12 ( SUS304 M 3 M SUSU316L 8 11 SUS304 2 7 A6063 6 9 6 9 10 9 5 SUS304 4 5 10 4 10 S O S O XLD-25 XLD-40,XLD-

H 4 S y m b o l Initial power/ Power 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 consumption (W) Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.

22 107 106 3 106 10 36 221 21 10 14 9 90 55 110 50 88 3.2 , , , 1 1 3 4 44 66 96 257 314 406 30 40 30 10 15 15 16 20 24 9 11 13 100 150 180 65 85 120 130 180 220 60 76 110 102 136 184 4.5 4.5 6 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AMF550 AMF650 AMF850 1 2 1 2 1 2 1 AMF450SAME, #4 AMF550SAME, #5 AMF650SAME, #6 AMF850SAME, #7 4.6-32 Series AMF Precautions Dimensions

bracket Model Port size (Nominal size B) A H B C D E F G I 221 J 25 K 10 L 14 N 90 O 55 P 110 Q 50 R 88 S 3.2 AM 1 2 3 4 , 9 36 205 19 100 106 3 106 10 AMF450 212 22 107 106 3 106 10 36 221 21 10 14 9 90 55 110 50 88 3.2 1 Misc. , , , 1 1 4.5 4.5 6 3 4 257 314 406 30 40 30 10 15 15 16 20 24 9 11 13 100 150 180 65 85 120 130 180 220 60 76 110 102 136 184 44 66 96 239 291 403 22 32 42 128 167

Note 2) Measurement values based on a charged plate (dimensions: 150 x 150 mm, electrostatic capacity: 20pF) defined by ANSI standard (ANSI/ESD STM3.1-2006). Distance between charged plate and ionizer: 100 mm, Air purge: 0.3 MPa (energy saving nozzle) / 0.1 MPa (high flow rate nozzle). Note 3) Charge elimination is not possible without air purge.